Nitinol Prosthesis in Stapes Surgery: Evolution from Heat-Activated to Superelastic Nitinol: A Systematic Review

被引:0
|
作者
Achena, Andrea [1 ]
Pacelli, Ludovica [1 ,2 ]
Prizio, Carmine [1 ,3 ]
Mantini, Gabriella [1 ]
Placentino, Angelo [4 ]
Accorona, Remo [1 ]
Valenzise, Valerio [1 ]
Pilolli, Francesco [1 ]
Ormellese, Giorgio Luigi [1 ]
Mevio, Niccolo [1 ]
Dragonetti, Alberto [1 ]
机构
[1] ASST Grande Osped Metropolitano Niguarda, Unit Otorhinolaryngol, I-20162 Milan, Italy
[2] Univ Milan, Dept Clin Sci & Community Hlth, I-20090 Milan, Italy
[3] Univ Turin, Dept Surg Sci, Div Otolaryngol, I-10126 Turin, Italy
[4] Garbagnate Milanese Hosp, Div Otorhinolaryngol, I-20024 Milan, Italy
关键词
otosclerosis surgery; stapes prosthesis; nitinol prostheses; air-bone gap reduction; hearing restoration; superelastic prostheses; heat-activated prostheses; complication rates in otosclerosis surgery; audiological outcomes; middle ear; artificial intelligence;
D O I
10.3390/jcm14041069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Stapes surgery is a well-established treatment for conductive hearing loss caused by otosclerosis, with the choice of prosthesis playing a pivotal role in audiological outcomes and safety. Heat-activated and superelastic nitinol prostheses are widely used, but their comparative effectiveness and complication profiles remain debated. This systematic review and meta-analysis aimed to evaluate the audiological outcomes, complication rates, and overall performance of these two prosthesis types. Methods: A systematic review was conducted following PRISMA guidelines. Seven studies involving 273 patients were included. Data on mean air-bone gap (ABG) reduction, complication rates, and follow-up outcomes were extracted. Meta-analyses were performed using a random-effects model, and odds ratios (OR) with 95% confidence intervals (CI) were calculated for comparative analysis. Results: The pooled mean ABG reduction was 20.2 dB (95% CI: 19.47-20.95), indicating substantial and comparable improvements in hearing for both prosthesis types. Heat-activated prostheses achieved slightly higher ABG reduction in individual studies, while superelastic prostheses offered advantages in procedural simplicity. Complication rates were 6.0% for heat-activated and 5.6% for superelastic prostheses. The most common complications included sensorineural hearing loss (2.0-2.4%) and incus-related issues such as necrosis and lateralization. Conclusions: Both prosthesis types provide comparable audiological outcomes and surgical success rates. However, the slightly lower complication rate observed with superelastic prostheses emphasizes their safety and predictability. The choice of prosthesis should be guided by patient anatomy, surgeon expertise, and procedural considerations. Future studies should prioritize long-term outcomes and standardized reporting to further refine prosthesis selection.
引用
收藏
页数:12
相关论文
共 15 条
  • [1] Effectiveness of the Heat-Activated Nitinol SMart Piston Stapes Prosthesis in Stapedectomy Surgery
    Cho, John J. W.
    Yunker, Warren K.
    Marck, Paulette
    Marck, Paul A.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2011, 40 (01): : 8 - 13
  • [2] Results Obtained With a New Superelastic Nitinol Stapes Prosthesis in Stapes Surgery
    Hornung, Joachim Albert
    Brase, Christoph
    Zenk, Johannes
    Iro, Heinrich
    OTOLOGY & NEUROTOLOGY, 2011, 32 (09) : 1415 - 1421
  • [3] Stapes surgery for otosclerosis using a new titanium prosthesis with a superelastic nitinol clip. First experiences
    Zirkler, J.
    Rahne, T.
    Plontke, S. K.
    HNO, 2016, 64 (02) : 111 - 116
  • [4] The heat-activated stapes prosthesis 'Smart' piston - Technique and preliminary results
    Babighian, Gregorio
    Fontana, Marco
    Caltran, Silvia
    OTOSCLEROSIS AND STAPES SURGERY, 2007, 65 : 190 - 196
  • [5] Retrospective analysis of the results of implanting Nitinol pistons with heat-crimping piston loops in stapes surgery
    Hornung, Joachim Albert
    Brase, Christoph
    Bozzato, Alessandro
    Zenk, Johannes
    Schick, Bernhard
    Iro, Heinrich
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2010, 267 (01) : 27 - 34
  • [6] Retrospective analysis of the results of implanting Nitinol pistons with heat-crimping piston loops in stapes surgery
    Joachim Albert Hornung
    Christoph Brase
    Alessandro Bozzato
    Johannes Zenk
    Bernhard Schick
    Heinrich Iro
    European Archives of Oto-Rhino-Laryngology, 2010, 267 : 27 - 34
  • [7] In vivo performance of the nitinol shape-memory stapes prosthesis during hearing restoration surgery in otosclerosis:: A first report
    Rajan, GP
    Eikelboom, RH
    Anandacoomaraswamy, KS
    Atlas, MD
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 305 - 309
  • [8] Comparison of manually crimping and laser-activated nitinol prosthesis in otosclerosis surgery: our experience of 98 patients
    Jutila, T.
    Hirvonen, T. P.
    Nicoli, T. K.
    Vnencak, M.
    Sinkkonen, S. T.
    CLINICAL OTOLARYNGOLOGY, 2017, 42 (03) : 728 - 731
  • [9] Systematic Review of the Literature on Nitinol Prostheses in Surgery for Otosclerosis: Assessment of the Adequacy of Statistical Power
    Van Rompaey, Vincent
    Claes, Gerd
    Potvin, Jorn
    Wouters, Kristien
    Van de Heyning, Paul H.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (03) : 357 - 366
  • [10] The Influence of Prosthesis Diameter in Stapes Surgery: A Meta-Analysis and Systematic Review of the Literature
    Laske, Roman D.
    Roeoesli, Christof
    Chatzimichalis, Michail Vasileios
    Sim, Jae Hoon
    Huber, Alexander M.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (04) : 520 - 528