Eddeep: Fast Eddy-Current Distortion Correction for Diffusion MRI with Deep Learning

被引:0
|
作者
Legouhy, Antoine [1 ,2 ,3 ]
Callaghan, Ross [3 ]
Stee, Whitney [4 ,5 ,6 ]
Peigneux, Philippe [4 ,5 ,6 ]
Azadbakht, Hojjat [3 ]
Zhang, Hui [1 ,2 ]
机构
[1] UCL, Ctr Med Image Comp, London, England
[2] UCL, Dept Comp Sci, London, England
[3] AINOSTICS Ltd, Manchester, Lancs, England
[4] Univ Libre Bruxelles ULB, CRCN Ctr Res Cognit & Neurosci, UR2NF Neuropsychol & Funct Neuroimaging Res Unit, Brussels, Belgium
[5] Univ Libre Bruxelles ULB, UNI ULB Neurosci Inst, Brussels, Belgium
[6] Univ Liege ULiege, GIGA Cyclotron Res Ctr In Vivo Imaging, Liege, Belgium
基金
“创新英国”项目; 英国医学研究理事会;
关键词
Diffusion MRI; Distortion correction; Eddy-currents; FRAMEWORK; ARTIFACTS;
D O I
10.1007/978-3-031-72069-7_15
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Modern diffusion MRI sequences commonly acquire a large number of volumes with diffusion sensitization gradients of differing strengths or directions. Such sequences rely on echo-planar imaging (EPI) to achieve reasonable scan duration. However, EPI is vulnerable to off-resonance effects, leading to tissue susceptibility and eddy-current induced distortions. The latter is particularly problematic because it causes misalignment between volumes, disrupting downstream modelling and analysis. The essential correction of eddy distortions is typically done post-acquisition, with image registration. However, this is non-trivial because correspondence between volumes can be severely disrupted due to volume-specific signal attenuations induced by varying directions and strengths of the applied gradients. This challenge has been successfully addressed by the popular FSL Eddy tool but at considerable computational cost. We propose an alternative approach, leveraging recent advances in image processing enabled by deep learning (DL). It consists of two convolutional neural networks: 1) An image translator to restore correspondence between images; 2) A registration model to align the translated images. Results demonstrate comparable distortion estimates to FSL Eddy, while requiring only modest training sample sizes. This work, to the best of our knowledge, is the first to tackle this problem with deep learning. Together with recently developed DL-based susceptibility correction techniques, they pave the way for real-time preprocessing of diffusion MRI, facilitating its wider uptake in the clinic.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [1] Unsupervised Deep Learning for FOD-Based Susceptibility Distortion Correction in Diffusion MRI
    Qiao, Yuchuan
    Shi, Yonggang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (05) : 1165 - 1175
  • [2] DEEP PENETRATION EDDY-CURRENT APPLICATIONS
    FLORA, JH
    MATERIALS EVALUATION, 1985, 43 (10) : 1298 - 1298
  • [3] A new eddy-current compensation method in MRI
    Ma, C.
    Jiang, X. H.
    PIERS 2007 BEIJING: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, PTS I AND II, PROCEEDINGS, 2007, : 1447 - +
  • [4] Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients
    Zhuang, Jiancheng
    Hrabe, Jan
    Kangarlu, Alayar
    Xu, Dongrong
    Bansal, Ravi
    Branch, Craig A.
    Peterson, Bradley S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 1188 - 1193
  • [5] DEEP PENETRATION MULTIFREQUENCY EDDY-CURRENT SYSTEM
    FLORA, JH
    MATERIALS EVALUATION, 1984, 42 (10) : A21 - A21
  • [6] A FAST EDDY-CURRENT DRIVEN HIGH-CURRENT SWITCH
    SCHMIDTHARMS, CA
    STOKES, AD
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (05): : 521 - 523
  • [7] Fast Transient Eddy-Current Analysis Using Error Correction Method for Series of Linear Systems
    Kawaguchi, Shigeru
    Mifune, Takeshi
    Iwashita, Takeshi
    Matsuo, Tetsuji
    2016 IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (CEFC), 2016,
  • [8] PULSED EDDY-CURRENT APPLICATION TO THE DETECTION OF DEEP CRACKS
    LEBRUN, B
    JAYET, Y
    BABOUX, JC
    MATERIALS EVALUATION, 1995, 53 (11) : 1296 - 1300
  • [9] A programmable eddy-current compensation system for MRI and localized spectroscopy
    Fry, ME
    Pittard, S
    Summers, IR
    Vennart, W
    Goldie, FTD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 455 - 458
  • [10] EDDY-CURRENT CORRECTION IN VOLUME-LOCALIZED MR SPECTROSCOPY
    LIN, C
    WENDT, RE
    EVANS, HJ
    ROWE, RM
    HEDRICK, TD
    LEBLANC, AD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06): : 823 - 827