Accuracy of Working Length Measurement Using Cone Beam Computed Tomography at Three Field of View Settings, Conventional Radiography, and Electronic Apex Locator: An Ex-vivo Study

被引:0
|
作者
Izadi, Arash [1 ]
Golmakani, Faezeh [1 ]
Kazeminejad, Ezatolah [1 ]
Mahdavi Asl, Amin [1 ]
机构
[1] Golestan Univ Med Sci, Dent Res Ctr, Gorgan, Iran
来源
EUROPEAN ENDODONTIC JOURNAL | 2024年 / 9卷 / 03期
关键词
Apex locator; cone-beam computed tomography; conventional radiography; field of view; working length; CANAL LENGTH; PERIAPICAL RADIOGRAPHY; SOFTWARE; POSITION;
D O I
10.14744/eej.2023.97769
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Determining the working length (WL) in root canal treatment facilitates the treatment prognosis. The introduction of apex locators and new devices in dentistry influenced this consideration. This comparative study evaluated the accuracy of working length measurement by cone beam computed tomography (CBCT) in three fields of view (FOVs), conventional radiography, and the apex locator Raypex 5. Methods: The descriptive-analytical study was performed on 40 mandibular premolar teeth that met the inclusion criteria. Direct observation under the microscope was considered the gold standard and compared with measurements by the electronic apex locator, CBCT at three field of view settings and periapical images. The results were analyzed by paired t-tests and Wilcoxon tests.The level of significance was set at 0.05 (p=0.05). Results: Results showed that the CBCT at 5x5 FOV (p=0.733) and Conventional radiography(p=0.001) achieved the working lengths with the highest and lowest accuracy, respectively. In addition, the difference between actual and measured working length using conventional radiography was significant (p<0.05). Conclusion: According to the results of this study, CBCT images at different FOVs and those taken by the apex locator Raypex 5 can be used as a reliable method for estimating the working length.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 50 条
  • [1] Accuracy of working length measurement: electronic apex locator versus cone-beam computed tomography
    Lucena, C.
    Lopez, J. M.
    Martin, J. A.
    Robles, V.
    Gonzalez-Rodriguez, M. P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (03) : 246 - 256
  • [2] Performance of the Working Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length
    Yildirim, Cihan
    Aktan, Ali Murat
    Karataslioglu, Emrah
    Aksoy, Fatih
    Isman, Ozlem
    Culha, Emre
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (01)
  • [3] Accuracy of Working Length Determination- Electronic Apex Locator Versus Cone Beam Computed Tomography
    Kumari, Sunayna
    Memon, Sharjeel
    Arjumand, Bilal
    Siddiqui, Amna Yusuf
    Memon, Jazib
    Alothmani, Osama Shujaa
    Issrani, Rakhi
    Memon, Muhmmad Rizwan
    Iqbal, Azhar
    Khattak, Osama
    Prabhu, Namdeo
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2024, 24
  • [4] Accuracy of working length determination with root ZX apex locator and radiography: An in vivo and ex vivo study
    Zand, Vahid
    Mokhtari, Hadi
    Lotfi, Mehrdad
    Reyhani, Mohammad Forough
    Sohrabi, Aydin
    Tehranchi, Pardis
    Zenouzi, Hamid Reza Mokhtari
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (36): : 7088 - 7091
  • [5] Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study
    Yilmaz, Funda
    Kamburoglu, Kivanc
    Senel, Bugra
    JOURNAL OF ENDODONTICS, 2017, 43 (01) : 152 - 156
  • [6] Endodontic length measurements using 3D Endo, cone-beam computed tomography, and electronic apex locator
    Khoa Van Pham
    BMC Oral Health, 21
  • [7] Endodontic length measurements using 3D Endo, cone-beam computed tomography, and electronic apex locator
    Van Pham, Khoa
    BMC ORAL HEALTH, 2021, 21 (01)
  • [8] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Wolf, Thomas Gerhard
    Krauss-Mironjuk, Anna
    Wierichs, Richard Johannes
    Briseno-Marroquin, Benjamin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study
    Thomas Gerhard Wolf
    Anna Krauß-Mironjuk
    Richard Johannes Wierichs
    Benjamín Briseño-Marroquín
    Scientific Reports, 11
  • [10] Accuracy of Three Electronic Apex Locators Compared with Digital Radiography: An Ex Vivo Study
    Cianconi, Luigi
    Angotti, Vincenzo
    Felici, Roberto
    Conte, Gabriele
    Mancini, Manuele
    JOURNAL OF ENDODONTICS, 2010, 36 (12) : 2003 - 2007