Feasibility of Ex Vivo Ligandomics

被引:0
|
作者
Waduge, Prabuddha [1 ]
Veettil, Remya Ammassam [1 ]
Zhang, Bojun [1 ]
Huang, Chengchi [1 ]
Tian, Hong [2 ]
Li, Wei [1 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[2] LigandomicsRx LLC, Houston, TX 77098 USA
基金
美国国家卫生研究院;
关键词
ligandomics; ex vivo ligandomics; in vivo ligandomics; Scg3; VEGF; ex vivo ligand binding assay;
D O I
10.3390/biom15010145
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We developed ligandomics for the in vivo profiling of vascular ligands in mice, discovering secretogranin III (Scg3) as a novel angiogenic factor that selectively binds to retinal vessels of diabetic but not healthy mice. This discovery led to the development of anti-Scg3 therapy for ocular vasculopathies. However, in vivo ligandomics requires intracardial perfusion to remove unbound phage clones, limiting its use to vascular endothelial cells (ECs). To extend ligandomics to non-vascular cells, we investigated ex vivo ligandomics. We isolated ECs and retinal ganglion cells (RGCs) from diabetic and healthy mouse retinas by immunopanning. We quantified the binding of clonal phages displaying Scg3 and vascular endothelial growth factor (VEGF), confirming that their binding patterns to isolated diabetic versus healthy ECs matched in vivo patterns. Additionally, Scg3 and VEGF binding to isolated RGCs reflected their in vivo activity. These results support the feasibility of ex vivo ligandomics. We further mapped ligands binding to immunopanned diabetic and healthy ECs and RGCs by ligandomics, confirming that Scg3 was enriched with selective binding to diabetic ECs but not healthy ECs or diabetic/healthy RGCs. These findings demonstrate the feasibility of ex vivo ligandomics, which can be broadly applied to various cell types, tissues, diseases, and species.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Ex vivo ligandomics to profile diabetic vs. healthy retinal cells for drug target discovery
    Li, Wei
    Waduge, Prabuddha
    Huang, Chengchi
    Li, Yumei
    Li, Jin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [2] Feasibility of ex Vivo FDG PET of the Colon
    Gollub, Marc J.
    Akhurst, Timothy J.
    Williamson, Matthew J.
    Shia, Jinru
    Humm, John L.
    Wong, W. Douglas
    Paty, Philip B.
    Guillem, Jose G.
    Weiser, Martin R.
    Temple, Larissa K. F.
    Dauer, Lawrence T.
    Jhanwar, Suresh C.
    Kronman, Rachel E.
    Montalvo, Carolina V.
    Miller, Allison R.
    Larson, Steven M.
    Margulis, Alexander R.
    RADIOLOGY, 2009, 252 (01) : 232 - 239
  • [3] Surgical Robot for Intraluminal Access: An Ex Vivo Feasibility Study
    Nakadate, Ryu
    Iwasa, Tsutomu
    Onogi, Shinya
    Arata, Jumpei
    Oguri, Susumu
    Okamoto, Yasuharu
    Akahoshi, Tomohiko
    Eto, Masatoshi
    Hashizume, Makoto
    Cyborg and Bionic Systems, 2020, 2020
  • [4] Histotripsy for the Treatment of Cholangiocarcinoma Liver Tumors: In Vivo Feasibility and Ex Vivo Dosimetry Study
    Hendricks-Wenger, Alissa
    Weber, Peter
    Simon, Alex
    Saunier, Sofie
    Coutermarsh-Ott, Sheryl
    Grider, Douglas
    Vidal-Jove, Joan
    Allen, Irving Coy
    Luyimbazi, David
    Vlaisavljevich, Eli
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (09) : 2953 - 2964
  • [5] Hybrid System for Ex Vivo Hemorheological and Hemodynamic Analysis: A Feasibility Study
    Eunseop Yeom
    Yang Jun Kang
    Sang Joon Lee
    Scientific Reports, 5
  • [6] Feasibility of diagnostic interstitial ex-vivo mammary autofluorescence microendoscopy
    Monjazebi, Dena
    Douplik, Alexandre
    Leong, Wey
    Done, Susan
    Kulkarni, Supriya
    Wilson, Brian
    Easson, Alexandra
    ANNALS OF SURGICAL ONCOLOGY, 2017, 24 : 191 - 192
  • [7] The Feasibility of LigaSure to Create Intestinal Anastomosis: Results of Ex Vivo Study
    Santini, Mario
    Fiorelli, Alfonso
    Messina, Gaetana
    Mazzella, Antonio
    Accardo, Marina
    SURGICAL INNOVATION, 2015, 22 (03) : 266 - 273
  • [8] Hybrid System for Ex Vivo Hemorheological and Hemodynamic Analysis: A Feasibility Study
    Yeom, Eunseop
    Kang, Yang Jun
    Lee, Sang Joon
    SCIENTIFIC REPORTS, 2015, 5
  • [9] Robotic cochlear implantation: feasibility of a multiport approach in an ex vivo model
    Daniel Schneider
    Igor Stenin
    Juan Ansó
    Jan Hermann
    Fabian Mueller
    Gabriela Pereira Bom Braga
    Christoph Rathgeb
    Wilhelm Wimmer
    Joerg Schipper
    Julia Kristin
    Marco Caversaccio
    Lukas Anschuetz
    Stefan Weber
    Thomas Klenzner
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 1283 - 1289
  • [10] Robotic cochlear implantation: feasibility of a multiport approach in an ex vivo model
    Schneider, Daniel
    Stenin, Igor
    Anso, Juan
    Hermann, Jan
    Mueller, Fabian
    Braga, Gabriela Pereira Bonn
    Rathgeb, Christoph
    Wimmer, Wilhelm
    Schipper, Joerg
    Kristin, Julia
    Caversaccio, Marco
    Anschuetz, Lukas
    Weber, Stefan
    Klenzner, Thomas
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (05) : 1283 - 1289