Patient-Specific Acetabular Safe Zones in Total Hip Arthroplasty: External Validation of a Quantitative Approach to Preoperatively Templating Spinopelvic Parameters

被引:0
|
作者
Pang, Michael [1 ,2 ]
Vigdorchik, Jonathan M. [3 ]
Schwarzkopf, Ran [4 ]
Chen, Antonia F. [1 ,2 ]
Iorio, Richard [1 ,2 ]
Lange, Jeffrey K. [1 ,2 ]
Ramkumar, Prem N. [5 ]
机构
[1] Harvard Med Sch, Dept Orthopaed Surg, Boston, MA USA
[2] Brigham & Womens Hosp, Dept Orthopaed Surg, Boston, MA USA
[3] Hosp Special Surg, New York, NY USA
[4] NYU, Langone Hlth, New York, NY USA
[5] Commons Clin, 3828 Schaufele Ave Ste 308, Long Beach, CA 90808 USA
来源
ARTHROPLASTY TODAY | 2024年 / 30卷
关键词
Total hip arthroplasty; Revision; Spinopelvic; Instability; Safe-zones; SPINAL DEFORMITY; PELVIC TILT; COMPONENT; ORIENTATION; ANTEVERSION; MOBILITY; IMPINGEMENT; INCLINATION; INSTABILITY; POSITION;
D O I
10.1016/j.artd.2024.101508
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Spinopelvic mechanics are critical in total hip arthroplasty; however, there is no established consensus for adjusting acetabular component positioning based on spinopelvic parameters. This study aimed to (1) validate a recently developed Patient-Specific acetabular safe-zone calculator that factors in spinopelvic parameters and (2) compare differences with hip-spine classification targets. Methods: A total of 3750 patients underwent primary total hip arthroplasty across 3 academic referral centers, with 33 (0.88%) requiring revision for instability. Spinopelvic parameters were measured before initial total hip arthroplasty, and acetabular component position was measured following the index and revision procedures. Most operations employed either computer navigation or robotic assistance (94%). Surgical approaches included both anterior and posterior techniques. Utilizing our recently developed patient-specific safe-zone calculator, theoretical intraoperative positions were calculated and compared to true component positions before and after revision. Results: Among 33 patients who underwent revision, none dislocated at an average follow-up of 5.1 years. In the external validation cohort, the average absolute differences between the patient-specific safe-zone and the median hip-spine classification recommendation were 3.8 degrees +/- 2.1 degrees inclination and 5.0 degrees +/- 3.2 degrees version. For the pooled cohort, the absolute differences between the patient-specific safe-zone targets and the prerevision component positions were 7.9 degrees +/- 5.1 degrees inclination and 11.4 degrees +/- 6.9 degrees version. After revision, the mean absolute differences decreased to 3.6 degrees +/- 3.1 degrees inclination and 5.8 degrees +/- 3.5 degrees version (P < .001). Conclusions: A patient-specific approach improved acetabular component positioning accuracy within 6 degrees of version and 4 degrees of inclination of stable, revised hips. Patient-specific safe zones provide quantitative targets for nuanced spinopelvic preoperative planning that may mitigate risk of instability and may indicate use of assisted technologies. (c) 2024 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Patient-Specific Safe Zones for Acetabular Component Positioning in Total Hip Arthroplasty: Mathematically Accounting for Spinopelvic Biomechanics
    Ramkumar, Primary Hip Prem N.
    Pang, Michael
    Vigdorchik, Jonathan M.
    Chen, Antonia F.
    Iorio, Richard
    Lange, Jeffrey K.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (09): : 1779 - 1786
  • [2] Laboratory validation of patient-specific templating for total knee arthroplasty
    Hafez, Mahmoud A.
    Jansen, Arne
    Portheine, Frank
    Jaramaz, Branislav
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [3] Patient-Specific Guides for Total Hip Arthroplasty: A Paired Acetabular and Femoral Implantation Approach
    Stegman, Jacob
    Casstevens, Chris
    Kelley, Todd
    Nistor, Vasile
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (01):
  • [4] TECHNIQUES FOR OPTIMIZING ACETABULAR COMPONENT POSITIONING IN TOTAL HIP ARTHROPLASTY Defining a Patient-Specific Functional Safe Zone
    Feng, James E.
    Anoushiravani, Afshin A.
    Eftekhary, Nima
    Wiznia, Daniel
    Schwarzkopf, Ran
    Vigdorchik, Jonathan M.
    JBJS REVIEWS, 2019, 7 (02)
  • [5] Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty
    Spencer-Gardner, L.
    Pierrepont, J.
    Topham, M.
    Bare, J.
    McMahon, S.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2016, 98B (10): : 1342 - 1346
  • [6] Patient-specific planning in total hip arthroplasty
    Floerkemeier, Thilo
    ARTHROSKOPIE, 2021, 34 (05) : 377 - 384
  • [7] Reliability of Templating with Patient-Specific Instrumentation in Total Knee Arthroplasty
    Issa, Kimona
    Rifai, Aiman
    McGrath, Mike S.
    Callaghan, John J.
    Wright, Craig
    Malkani, Arthur L.
    Mont, Michael A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2013, 26 (06) : 429 - 433
  • [8] Design considerations for patient-specific surgical templates for total hip arthroplasty with respect to acetabular cartilage
    Mueller, Samuel
    Ahmad, Intsar
    Kraemer, Manuel
    Utz, Michael
    Gaa, Johannes
    Kahrs, Lueder A.
    Ortmaier, Tobias
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (03): : 263 - 269
  • [9] Low dislocation rates with the use of patient specific "Safe zones" in total hip arthroplasty
    Sharma, Abhinav K.
    Cizmic, Zlatan
    Dennis, Douglas A.
    Kreuzer, Stefan W.
    Miranda, Michael A.
    Vigdorchik, Jonathan M.
    JOURNAL OF ORTHOPAEDICS, 2021, 27 : 41 - 48
  • [10] Patient-Specific Restoration of Biomechanics in Total Hip Arthroplasty
    Weber, Markus
    Grifka, Joachim
    Renkawitz, Tobias
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2019, 157 (03): : 292 - 300