A New Self-Made 16-Channel Capacitive Electrocardiography System: An Investigation and Validation for Non-Contact Electrodes

被引:0
|
作者
Yang, Jinru [1 ,2 ]
Wang, Tianjun [2 ]
Cui, Haipo [1 ]
Sun, Limin [2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol SIMIT, CAS Ctr Excellence Superconducting Elect CENSE, Shanghai 200050, Peoples R China
基金
国家重点研发计划;
关键词
non-contact electrode; cECG; motion artifacts; MNF; power line noise;
D O I
10.3390/s25020445
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time. The bias feedback as a critical technique was routed to the left hand with the wet Ag/AgCl electrode, which could greatly suppress the power line noise. After all artifacts were removed, the ECG signals could be discerned clearly. We demonstrated that the ECG signals acquired with the capacitive electrodes were similar to those with the wet electrode. Thus, we successfully provide a new configuration for cECG monitoring at home or in a clinical setting.
引用
收藏
页数:14
相关论文
共 5 条
  • [1] Investigation of Non-Contact Biometric System Using Capacitive Coupling Electrodes
    Mizusako, Motoki
    Yasushi, Mitsuo
    Hashimoto, Hideki
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 2775 - 2780
  • [2] An Auto Loss Compensation System for Non-contact Capacitive Coupled Body Channel Communication
    Zhao, Jian
    Mao, Jingna
    Zhou, Tong
    Lai, Longqiang
    Yang, Huazhong
    Zhao, Bo
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [3] Capacitive Coupled Electrodes based Non-contact ECG Measurement System with Real-time Wavelet Denoising Algorithm
    Peng, Shun
    Bao, Shenjie
    Chen, Wei
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6587 - 6590
  • [4] Fabrication and evaluation of micro-channel array for flexible on-chip PEMFC by new evaluation method and self-made hot embossing system
    Zhuqing Wang
    Jinlong Lv
    Jinhua Li
    Yang Wang
    Jingshuai Sun
    The International Journal of Advanced Manufacturing Technology, 2020, 108 : 1381 - 1387
  • [5] Fabrication and evaluation of micro-channel array for flexible on-chip PEMFC by new evaluation method and self-made hot embossing system
    Wang, Zhuqing
    Lv, Jinlong
    Li, Jinhua
    Wang, Yang
    Sun, Jingshuai
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2020, 108 (5-6): : 1381 - 1387