Optimised determination of arsenic and lead in tea samples using microwave-assisted digestion and ICP-MS: method validation and health risk assessment

被引:0
|
作者
Saber, Ayman [1 ,2 ,3 ]
Malhat, Farag [1 ,2 ]
Saber, El-Sayed [1 ,2 ]
Shokr, Shokr Abdelsalam [1 ,2 ]
机构
[1] Agr Res Ctr, Pesticide Residues & Environm Pollut Dept, Cent Agr Pesticide Lab, Giza, Egypt
[2] Agr Res Ctr, Natl Ctr Monitoring Pesticide Residues & Pollutant, Cent Agr Pesticide, Giza, Egypt
[3] Univ Cordoba, Inst Chem Energy & Environm, Dept Analyt Chem, Cordoba, Spain
关键词
Heavy metals; microwave acid-digestion; ICP-MS; method validation; tea; HEAVY-METALS; BLACK TEA; SOIL; CONTAMINATION; VARIETIES; POLLUTION; CADMIUM; WATER;
D O I
10.1080/03067319.2025.2452952
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Heavy metal contamination in tea poses significant risks to consumer health, necessitating the development of accurate and efficient analytical methods for routine monitoring. This study aimed to optimise and validate a robust process for the simultaneous determination of arsenic (As) and lead (Pb) in dried tea samples using inductively coupled plasma mass spectrometry (ICP-MS) following microwave-assisted digestion. These toxic elements were selected due to their known health risks and their frequent detection in tea. The method was systematically optimised for digestion parameters and validated following EURACHEM guidelines to ensure accuracy and precision. Key validation metrics included linearity (R2 >= 0.9999), limits of quantification (LOQ) of 0.25 mu g/kg for As and 1.5 mu g/kg for Pb, sufficient for regulatory compliance. The method demonstrated excellent mean recoveries (75%-89%) and relative standard deviations (RSDs) below 15% across all fortification levels. Precision and accuracy were further verified through proficiency testing, yielding acceptable z-scores for both analytes. Application of the validated method to tea samples collected from Egypt revealed arsenic concentrations ranging from 0.018 +/- 0.004 to 0.280 +/- 0.070 mg/kg and lead concentrations from 0.083 +/- 0.021 to 1.630 +/- 0.407 mg/kg. Although detection rates were elevated, the calculated target hazard quotient (THQ) values for As and Pb were below the threshold of 1, suggesting no significant non-carcinogenic health risks associated with tea consumption. This study provides a reliable, cost-effective analytical framework for monitoring heavy metal contamination in tea products, supporting consumer safety and public health initiatives.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] ICP-MS multielement determination in fly ash after microwave-assisted digestion of samples
    Das, AK
    Chakraborty, R
    de la Guardia, M
    Cervera, ML
    Goswami, D
    TALANTA, 2001, 54 (05) : 975 - 981
  • [2] Determination of platinum and rhodium in dust and plant samples using microwave-assisted sample digestion and ICP-MS
    Niemelä, M
    Perämäki, P
    Piispanen, J
    Poikolainen, J
    ANALYTICA CHIMICA ACTA, 2004, 521 (02) : 137 - 142
  • [3] Determination of heavy metals in crayfish by ICP-MS with a microwave-assisted digestion treatment
    López, FJS
    Garcia, MDG
    Morito, NPS
    Vidal, JLM
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2003, 54 (02) : 223 - 228
  • [4] Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
    Rantasa, Matjaz
    Majer, David
    Finsgar, Matjaz
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [5] Validation of an optimised microwave-assisted acid digestion method for trace and ultra-trace elements in indoor PM2.5 by ICP-MS analysis
    Camilleri, Renato
    Stark, Christopher
    Vella, Alfred J.
    Harrison, Roy M.
    Aquilina, Noel J.
    HELIYON, 2023, 9 (01)
  • [6] Microwave-assisted digestion method using diluted nitric acid and hydrogen peroxide for the determination of major and minor elements in milk samples by ICP-OES and ICP-MS
    Lee, Jian
    Park, Ye-Seul
    Lee, Hwa-Jeong
    Koo, Yong Eui
    FOOD CHEMISTRY, 2022, 373
  • [7] Determination of trace element concentrations in tomato samples at different stages of maturation by ICP OES and ICP-MS following microwave-assisted digestion
    Bressy, Fernanda C.
    Brito, Geysa B.
    Barbosa, Isa S.
    Teixeira, Leonardo S. G.
    Korn, Maria Gracas A.
    MICROCHEMICAL JOURNAL, 2013, 109 : 145 - 149
  • [8] A rapid method for the determination of trace element impurities in silicone oils by ICP-MS after microwave-assisted digestion
    Depto. de Quim. Analítica, Universidad de Valencia, Dr. Moliner 50, E-46100 Burjassot, Valencia, Spain
    不详
    Spectrosc Lett, 6 (1245-1253):
  • [9] A rapid method for the determination of trace element impurities in silicone oils by ICP-MS after microwave-assisted digestion
    Das, AK
    Chakarborty, R
    Cervera, ML
    de la Guardia, M
    SPECTROSCOPY LETTERS, 1998, 31 (06) : 1245 - 1253
  • [10] Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS
    H. Kawamura
    H. Tagomori
    N. Matsuoka
    Y. Takashima
    S. Tawaki
    N. Momoshima
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 717 - 720