Long-Term Outcomes of Endovascular Aortic Repair with Parallel Chimney or Periscope Stent Grafts for Ruptured Complex Abdominal Aortic Aneurysms

被引:0
|
作者
Kopp, Reinhard [1 ,2 ]
Stachowski, Lukas [1 ]
Puippe, Gilbert [3 ]
Zimmermann, Alexander [1 ]
Menges, Anna-Leonie [1 ]
机构
[1] Univ Hosp Zurich, Dept Vasc Surg, CH-8091 Zurich, Switzerland
[2] Univ Hosp Regensburg, Sect Vasc & Endovascular Surg, D-93053 Regensburg, Germany
[3] Univ Hosp Zurich, Dept Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
关键词
ruptured abdominal aortic aneurysm; endovascular aortic repair; parallel grafts; chimney; periscope; gutter endoleak; parallel stent graft; EVAR; MULTICENTER EXPERIENCE; ENDOGRAFT REPAIR; PATHOLOGIES; ARTERY;
D O I
10.3390/jcm14010234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The parallel stent graft endovascular aortic repair (PGEVAR) technique is an off-the-shelf option used for elective complex abdominal aortic aneurysm repair with acceptable outcome results, as reported so far. The PGEVAR technique, using chimney or periscope parallel grafts, can also be used for patients with ruptured complex abdominal aortic aneurysms. However, only few data about the mid- to long-term outcomes are available. Methods: Data from patients treated between August 2009 and July 2023 with the PGEVAR technique for ruptured complex abdominal aortic aneurysms were analyzed. The endpoints of this study were primary and secondary technical success, perioperative mortality, rate of proximal type 1a (gutter) endoleaks (T1aEL), and overall and aneurysm-related survival. Secondary endpoints were major adverse events, durability of parallel grafts, and factors associated with overall survival. Results: Twenty patients (mean age: 77 +/- 9 y; 18 male) with ruptured complex abdominal aortic aneurysm were treated, receiving PGEVAR for ruptured juxtarenal (n = 11), suprarenal (n = 7), or distal thoracoabdominal Crawford IV aortic aneurysms (n = 2) with a mean diameter of 82 +/- 18 mm (range 59-120). The patients had PGEVAR with implantation of 39 parallel grafts (1.95 PGs per patient; 23 chimney and 16 periscope) for revascularization of the celiac artery (n = 3), superior mesenteric artery (n = 9), and renal arteries (n = 27). Three patients had delayed PG implantation within 10 days. Primary technical success was 15/20 (75%) with five patients having an early proximal T1aEL, three of them having successful reintervention (secondary success rate: 18/20; 90%), with no persistent bleeding. Two patients had late T1aELs. The presence of an early T1aEL was related to the number of PGs (>= 2) implanted (p = 0.038) or insufficient aortic SG oversizing (p = 0.038). In-hospital mortality was 1/20 (5%). Perioperative mortality up to 32 days was 3/20 (15%), with two further late aneurysm-related deaths and eight late aneurysm-unrelated deaths (overall mortality 13/20; 65%) during follow-up (median 34 months; range 1-115). Major adverse events were observed in 11 (55%) patients. Secondary parallel stent graft patency at 1 and 3 years was 97.4 and 94.1%. During follow-up, aneurysm sac behavior was determined in 19 patients, which showed diameter progression (n = 3), stable aneurysm disease (n = 3), and aneurysm diameter regression in 13 (68.4%) patients. Overall survival was 75% after 1 year, and 53% and 22% after 3 and 5 years. Factors associated with overall long-term survival were age < 80 years (p = 0.037), juxtarenal aneurysms (p = 0.023), the absence of major adverse events (p = 0.025), and aneurysm sac regression (p = 0.003). Conclusions: Treatment of ruptured complex abdominal aortic aneurysm with the PGEVAR technique is associated with acceptable perioperative and long-term outcomes with high PG patency rates. Early proximal T1aELs are observed with a relevant frequency, requiring early reintervention with successful sealing of most relevant endoleaks. To note, limitation of the number of parallel stent grafts implanted at the proximal aortic sealing sites, sufficient PG sealing length, and adequate main aortic SG oversizing are most relevant to avoid T1a (gutter) ELs. The selection of juxtarenal aortic aneurysms and evidence for aneurysm sac diameter regression after PGEVAR had a prognostic impact.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Early and Midterm Outcomes of Chimney Endovascular Aortic Repair for Ruptured Abdominal Aortic Aneurysms
    Takeuchi, Yuriko
    Morikage, Noriyasu
    Sakamoto, Ryunosuke
    Otsuka, Ryo
    Ike, Soichi
    Mizoguchi, Takahiro
    Samura, Makoto
    Harada, Takasuke
    Kurazumi, Hiroshi
    Suzuki, Ryo
    Suehiro, Kotaro
    Hamano, Kimikazu
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [2] Long-term Results of Aortouniiliac Stent Grafts for the Endovascular Repair of Abdominal Aortic Aneurysms
    Dortch, John D.
    Oldenburg, W. Andrew
    Farres, Houssam
    Rawal, Bhupendra
    McKinney, J. Mark
    Paz-Fumagalli, Ricardo
    Hakaim, Albert G.
    ANNALS OF VASCULAR SURGERY, 2014, 28 (05) : 1258 - 1265
  • [3] Long-term Outcomes Following Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms
    Gueroult, Aurelien M.
    Khan, Farhaan A.
    Stather, Philip W.
    Harrison, Seamus C.
    Boyle, Jonathan R.
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (03) : 428 - 435
  • [4] Outcomes of Chimney or Snorkel Endovascular Repair for Symptomatic and Ruptured Abdominal Aortic Aneurysms
    Jernigan, Eric G.
    Conway, Allan M.
    Tran, Nhan Nguyen
    Qato, Khalil
    Giangola, Gary
    Carroccio, Alfio
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E101 - E101
  • [5] Outcomes of chimney/snorkel endovascular repair for symptomatic and ruptured abdominal aortic aneurysms
    Jernigan, Eric Galloway
    Nhan Nguyen Tran
    Qato, Khalil
    Giangola, Gary
    Carroccio, Alfio
    Conway, Allan Marc
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (04) : 1117 - 1124
  • [6] Long-term outcomes following exclusive use of endovascular aortic repair for ruptured infrarenal abdominal aortic aneurysms
    Wang, Ruihan
    Yuan, Tong
    Kan, Yuanqing
    Yue, Jianing
    Chen, Bin
    Dong, Zhihui
    Guo, Daqiao
    Si, Yi
    Fu, Weiguo
    CHINESE MEDICAL JOURNAL, 2023, 136 (15) : 1876 - 1878
  • [7] Long-term outcomes following exclusive use of endovascular aortic repair for ruptured infrarenal abdominal aortic aneurysms
    Wang Ruihan
    Yuan Tong
    Kan Yuanqing
    Yue Jianing
    Chen Bin
    Dong Zhihui
    Guo Daqiao
    Si Yi
    Fu Weiguo
    中华医学杂志英文版, 2023, 136 (15)
  • [8] Long-term outcomes of chimney endovascular aneurysm repair procedure for complex abdominal aortic pathologies
    Verlato, Paolo
    Foresti, Leonardo
    Bloemert-Tuin, Trijntje
    Trimarchi, Santi
    Hazenberg, Constantijn E. V. B.
    Herwaarden, Joost A. van
    JOURNAL OF VASCULAR SURGERY, 2024, 80 (03) : 612 - 620
  • [9] Population-based long-term outcomes of open versus endovascular aortic repair of ruptured abdominal aortic aneurysms
    Salata, Konrad
    Hussain, Mohamad A.
    de Mestral, Charles
    Greco, Elisa
    Awartani, Hadeel
    Aljabri, Badr A.
    Mamdani, Muhammad
    Forbes, Thomas L.
    Bhatt, Deepak L.
    Verma, Subodh
    Al-Omran, Mohammed
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (06) : 1867 - +
  • [10] Use of hybrid aortic stent grafts for endovascular repair of abdominal aortic aneurysms: Indications and outcomes
    Wirthlin, DJ
    Alcocer, F
    Whitley, D
    Jordan, WD
    JOURNAL OF SURGICAL RESEARCH, 2002, 108 (01) : 14 - 19