Experimental and numerical studies on fire resistance of damaged traditional mortise-tenon jointed timber frames

被引:0
|
作者
Lu, Yu [1 ,3 ]
Song, Xiaobin [1 ,2 ]
Peng, Yiqing [1 ]
Zhang, Baozhuang [1 ,2 ]
Chen, Yunxiao [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai 200092, Peoples R China
[3] Minist Housing & Urban Rural Dev Republ China, Beijing 100835, Peoples R China
来源
基金
中国国家自然科学基金; 中国博士后科学基金; 上海市自然科学基金;
关键词
Traditional timber structures; Mortise-tenon jointed timber frame; Looseness; Decay; Fire resistance; Sequentially coupled thermo-mechanical anal-ysis; Degradation mechanism; BEHAVIOR;
D O I
10.1016/j.jobe.2025.112213
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The looseness and decay damage in mortise-tenon (M&T) joints are commonly seen in the traditional timber frame, severely threatening the safety and fire resistance of traditional timber structures. To study the influence of deterioration to M&T joint on the fire resistance of traditional timber frame, we fabricated four 1/1.14-scaled traditional M&T jointed timber frame specimens, two without damage, one considering the looseness to joint, and one considering the decay of joint. The static loading test for one intact timber frame was carried out at normal temperature. Based on this, fire resistance tests of the specimens with different types of damage and 30 % fire load ratio were conducted under ISO 834 fire exposure. The failure mode, section temperature distribution, and wood charring rate of the frames after being exposed to fire were obtained, and the influence mechanism of damage to M&T joint on the fire resistance was revealed. The results indicated that the joint damage would remarkably change the failure mode and reduce the fire endurance; The non-damaged specimen experienced the joint failure after being exposed to fire for 55.5 min, while the specimens with the looseness and decay of joint suffered the bending failure at the mid span of the beam after being exposed to fire for 28.3 and 33.2 min, respectively. Furthermore, the heat transfer and sequentially coupled thermomechanical analysis models of the traditional timber frames consider the joint's damage were developed and verified using the test results. The parametric analyses were also performed to analyze the effects of different fire load ratios, loose and decay degree of the joint on the fire resistance of the timber frame. It is found that the model predictions were in good agreement with the test results. When the fire exposure time was constant, with an increase in the fire load ratio and the joint's looseness degree, the bending stiffness of the beam and joint's rotational stiffness of the timber frame significantly decreased. With an increase in the fire load ratio and the degree of looseness and decay, and the fire endurance of the frame decreased. When the fire load ratio decreased from 30 % to 10 %, the fire endurance of the frame increased by 26 %; Conversely, when the fire load ratio increased to 60 %, the fire endurance reduced by 48 %. Compared to non- damaged condition, when the looseness degree of joint in the frame was 22 %, the fire endurance of the frame reduced by up to 70 %; With a decay degree of joint in the frame of 22 %, the fire endurance of the frame reduced by up to 60 %.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Experimental Study on the Reinforcement Methods and Lateral Resistance of Mortise-Tenon Jointed Traditional Timber Frames
    Yang, Deshan
    Xu, Ming
    Chen, Zhongfan
    BIORESOURCES, 2021, 16 (02): : 4039 - 4051
  • [2] Experimental study on fire resistance of traditional timber mortise-tenon joints with damages
    Song, Xiao-bin
    Zhang, Yu
    Lu, Yu
    Peng, Yi-qing
    Zhou, Haizhu
    FIRE SAFETY JOURNAL, 2023, 138
  • [3] Lateral performance of mortise-tenon jointed traditional timber frames with wood panel infill
    Emile, Crayssac
    Song Xiaobin
    Wu Yajie
    Li Kai
    ENGINEERING STRUCTURES, 2018, 161 : 223 - 230
  • [4] Experimental study on fire resistance of post-beam timber frames with traditional mortise-tenon joints with damage
    Gao, Yuan
    Song, Xiao-bin
    Peng, Yi-qing
    ENGINEERING STRUCTURES, 2025, 333
  • [5] Experimental Study on the Traditional Timber Mortise-Tenon Joints
    Li, Xiaowei
    Zhao, Junhai
    Ma, Guowei
    Huang, Shuanghua
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (12) : 2089 - 2102
  • [6] Lateral performance of mortise-tenon jointed frames in multi-story traditional heavy timber structures: Mechanism and quantification
    Wu, Ya-Jie
    Lin, He-Shou
    Wang, Lei
    Xie, Qi-Fang
    Zhang, Li-Peng
    ENGINEERING STRUCTURES, 2023, 288
  • [7] Inelastic Behavior of Mortise-Tenon Jointed Traditional Timber Frame with Free-Standing Columns
    Yu, Pan
    Li, Tieying
    Yang, Qingshan
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024, 18 (07) : 1059 - 1076
  • [8] Experimental studies on the characteristic of mortise-tenon joint in historic timber buildings
    Department of Civil Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
    不详
    不详
    Gongcheng Lixue, 2006, 10 (168-173):
  • [9] EXPERIMENTAL STUDIES ON THE CHARACTERISTIC OF MORTISE-TENON JOINT IN HISTORIC TIMBER BUILDINGS
    Ge, Hong-Peng
    Wu, Kai
    Xue, Jian-Yang
    Bai, Jian-Fang
    Yao, Kan
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 587 - 594
  • [10] Experimental study on dovetail mortise-tenon joints with viscoelastic dampers in traditional timber structures
    Nie Y.
    Tao Z.
    Gao Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (01): : 125 - 133