A Comparative Evaluation of Fracture Resistance of Three Post Systems and Their Mode of Failure: An In-Vitro Study

被引:0
|
作者
Sundesha, Manish [1 ]
Choudhary, Anita [2 ]
Gubrellay, Priyanka [3 ]
Negi, Eishita [4 ]
Chhina, Harleen [4 ]
Jain, Omni P. [5 ]
Patel, Nikita [6 ]
机构
[1] Pacific Dent Coll & Res Ctr, Dept Conservat Dent & Endodont, Udaipur, Rajasthan, India
[2] Private Clin, Dept Conservat Dent & Endodont, Barmer, Rajasthan, India
[3] Autonomous State Med Coll, Dept Dent, Lalitpur, Uttar Pradesh, India
[4] Gian Sagar Dent Coll & Hosp, Dept Conservat Dent & Endodont, Patiala, Punjab, India
[5] Jaipur Dent Coll, Dept Conservat Dent & Endodont, Jaipur, Rajasthan, India
[6] Coll Dent Sci, Dept Conservat & Endodont, Bhavnagar, Gujarat, India
关键词
<italic>Custom cast post</italic>; <italic>Edelweiss post</italic>; <italic>glass fiber post</italic>; CORE; TEETH;
D O I
10.4103/jpbs.jpbs_948_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim:To analyze the fracture resistance of three post systems and their mechanism of failure.Materials and Procedures:Forty-five newly excised human mandibular single-rooted pre-molar, for periodontal or orthodontic reasons, were used. The teeth were separated into three groups (n = 15) based on the post system utilized. Group A had teeth restored with custom cast post; Group B had prefabricated glass fiber posts (Angelus post); and Group C with edelweiss composite post (Edelweiss Post).Results:The custom cast posts provided the highest fracture resistance but exhibited more unfavorable fractures. The edelweiss posts exhibited the least fracture resistance.Conclusion:Further investigations should be targeted at elucidating the force dynamics of this newer post system.
引用
收藏
页码:S3970 / S3972
页数:3
相关论文
共 50 条
  • [1] A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study
    Makade, Chetana S.
    Meshram, Ganesh K.
    Warhadpande, Manjusha
    Patil, Pravinkumar G.
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (02): : 90 - 95
  • [2] Evaluation of Fracture Resistance and Sites of Failure of Different Dowel Core Restorations: An In-Vitro Study
    Guragain, Manjeev
    Mathema, Suraj
    Rokaya, Dinesh
    OPEN DENTISTRY JOURNAL, 2019, 13 : 454 - 461
  • [3] Comparative evaluation of fracture resistance of glass fiber reinforced, carbon, and quartz post in endodontically treated teeth: An in-vitro study
    Sharma, Shweta
    Attokaran, George
    Singh, Kunwar S.
    Jerry, Jeethu J.
    Ahmed, Naima
    Mitra, Nirban
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (04): : 373 - 376
  • [4] Evaluation of the Fracture Resistance Offered by Three Different Intraorifice Barriers on Obturated Teeth: An In-vitro Study
    Mangaonkar, Sonam
    Foschi, Federico
    Fernandes, Kristlee sabrin
    Chalakkal, Paul
    Kadam, Nilesh
    Lambor, Rajan
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (10) : ZC33 - ZC37
  • [5] THE INFLUENCE OF POST MATERIAL ON FRACTURE RESISTANCE AND MODE OF FAILURE OF THE TEETH RECONSTRUCTED WITH POST SYSTEMS
    Vitalariu, Anca Mihaela
    Tatarciuc, Monica Silvia
    Diaconu, Diana
    Panaite, St.
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2009, 1 (01): : 44 - 48
  • [6] A Comparative Study of Fracture Resistance of Endodontically Treated Compromised Teeth with Different Post Systems: An In Vitro Study
    Malekipour, Mohammad Reza
    Hosseini, Neda
    Jafari, Niloufar
    Mazdak, Ali
    Mazaheri, Peiman
    Shirani, Farzaneh
    OPEN DENTISTRY JOURNAL, 2023, 17
  • [7] Comparative in-vitro evaluation of three chelator pastes
    Hülsmann, M
    Heckendorff, M
    Schäfers, F
    INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (08) : 668 - 679
  • [8] Fracture Resistance of Different Post-Core Systems: An In vitro Study
    Podili, Srivalli
    Puthenkandathil, Rahul
    Kulkarni, Manisha M.
    Alobaid, Mohammed A.
    Valluri, Bhanu P.
    Shaik, Zaheer A.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S239 - S243
  • [9] Fracture resistance of teeth restored with different post systems: in vitro study
    AL-Wahadni, Ahed M.
    Hamdan, Sami
    Al-Omiri, Mahmoud
    Hammad, Mohammad M.
    Hatamleh, Muhanad M.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (02): : E77 - E83
  • [10] Evaluation of the Fracture Resistance of Different Designs of All-Resin Post and Core Systems: An In Vitro Study
    Altassan, Mosa
    Alsulimani, Osamah
    Alzahrani, Bashayer M.
    Alghanemi, Abdulmajeed
    Abukhudhayr, Abdullah
    Alharbi, Shooq
    Munshi, Nabeel
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)