Diagnostic accuracy of strain cervical elastography as a predictor for preterm delivery: A single tertiary care centre study

被引:0
|
作者
Sharma, Abhinash [1 ]
Thakur, Shruti [1 ]
Tomar, Ashwani [1 ]
Mittal, Rita [2 ]
Surya, Mukesh [1 ]
机构
[1] IGMC, Dept Radiodiag, Shimla 171001, Himachal Prades, India
[2] IGMC, Dept Obstet & Gynecol, KNHM&C, Shimla, India
关键词
Preterm delivery; cervical ripening; elastography; colour code; strain ratio; UTERINE CERVIX; BIRTH; PREGNANCY; LENGTH; RISK; INDUCTION; SUCCESS; WOMEN;
D O I
10.1177/1742271X241277448
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Preterm delivery is a grave and demanding problem that accounts for the major cause of neonatal deaths and long-term morbidities. It remains an unresolved health issue of global dimensions. Cervical elastography is evolving as a useful diagnostic tool for its timely prediction so that individualised management can be done. Aim: To assess the diagnostic accuracy of transvaginal strain cervical elastography in prediction of preterm delivery. Methods: This prospective observational study was conducted from June 2021 to August 2022 in a tertiary care institute of North India. A total of 75 low-risk asymptomatic women were included. Transvaginal ultrasound was performed for the cervical length in the second and third trimesters. In addition, we collected strain elastography data such as colour codes from six regions of the cervix, that is, at the anterior and posterior lips of internal os, middle one-third of the cervix and the external os, and the strain ratios from these three cervical levels were also calculated. Then these parameters were compared with cervical length, second and third trimester groups and also with preterm and term delivery groups. Result: The red colour (soft colour) at the anterior lip of internal os was the best predictor of preterm delivery in our study with a sensitivity and specificity of 63.64% and 96.87%, respectively. The elastography strain ratio of >2 at the internal os and cervical length <= 2.8 cm were the additional predictors for the same. Conclusion: Cervical elastography can serve as a potential and reliable predictor for preterm delivery.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Value of cervical strain in ultrasound elastography as a predictor of spontaneous preterm delivery
    Abdallah, Yasmin Essam E. L. Din Mohamed
    Mostafa, Yassmen Hassan Ahmed
    Gaafar, Hassan Moustafa Ismaeil
    Hegazy, Rania Mohamed Abbas
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [2] Value of cervical strain in ultrasound elastography as a predictor of spontaneous preterm delivery
    Yasmin Essam EL Din Mohamed Abdallah
    Yassmen Hassan Ahmed Mostafa
    Hassan Moustafa Ismaeil Gaafar
    Rania Mohamed Abbas Hegazy
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [3] Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis
    Sun, Hui
    Lv, Qifeng
    Liu, Tingting
    Zhang, Nan
    Shi, Fengfeng
    SCOTTISH MEDICAL JOURNAL, 2023, 68 (03) : 110 - 120
  • [4] Diagnostic accuracy of cervical elastography in predicting preterm delivery A systematic review and meta-analysis
    Wang, Bo
    Zhang, Yong
    Chen, Shuangshuang
    Xiang, Xiaowei
    Wen, Juan
    Yi, Mei
    He, Baiyun
    Hu, Bing
    MEDICINE, 2019, 98 (29)
  • [5] Diagnostic Accuracy of FNAC in Tuberculosis Cervical Lymphadenitis-Experience from a Tertiary Care Centre
    Ahmed, Zeba
    Khalid, Muhammad
    Huma, Zille
    Mirza, Reema
    Mehfooz, Sana
    Raja, Nataliya
    ANNALS ABBASI SHAHEED HOSPITAL & KARACHI MEDICAL & DENTAL COLLEGE, 2024, 29 (01): : 12 - 18
  • [6] Cervical strain determined by ultrasound elastography and its association with spontaneous preterm delivery
    Hernandez-Andrade, Edgar
    Romero, Roberto
    Korzeniewski, Steven J.
    Ahn, Hyunyoung
    Aurioles-Garibay, Alma
    Garcia, Maynor
    Schwartz, Alyse G.
    Yeo, Lami
    Chaiworapongsa, Tinnakorn
    Hassan, Sonia S.
    JOURNAL OF PERINATAL MEDICINE, 2014, 42 (02) : 159 - 169
  • [7] Cervical shear wave elastography as a predictor of preterm delivery during 18-24 weeks of pregnancy
    Suthasmalee, Sasiwan
    Moungmaithong, Sakita
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2019, 45 (11) : 2158 - 2168
  • [8] Strain Cervical Elastography in Pregnancy: Feasibility Study and Its Usefulness in Prediction of Preterm Birth
    Shah, Nupur
    Kaul, Anita
    JOURNAL OF FETAL MEDICINE, 2018, 5 (03) : 155 - 158
  • [9] Diagnostic Accuracy of a Nurse-Led Transient Elastography A Study of a Tertiary Hospital Experience
    Kumari, Sanju
    George, Mini
    GASTROENTEROLOGY NURSING, 2023, 46 (02) : 118 - 127
  • [10] TVS-guided cervical strain elastography is more effective than measuring cervical length as an independent predictor of spontaneous preterm delivery in asymptomatic, high-risk women during the mid-trimester
    Vasudeva, Akhila
    Kodavati, Haritha
    Samanth, Jyothi
    Shivananda, Roopa Padavagodu
    Paladugu, Sanghamitra
    Raghav, Mridula
    Hanumaiah, Gagana
    Chaudhuri, Souvik
    Hegde, Nivedita
    Adiga, Prashanth
    Hebbar, Shripad
    Kumar, Pratap
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2024, 37 (01):