Analysis of the Radiological Anatomy of the Proximal Femur after the Intramedullary Nailing of Trochanteric Fractures

被引:0
|
作者
Maiorov, Boris A. [1 ,2 ,3 ]
Belen'kiy, Igor' G. [1 ,2 ]
Sergeev, Gennadii D. [1 ,2 ]
Endovitskiy, Ivan A. [3 ]
Sergeeva, Mariya A. [2 ]
Isakhanyan, David A. [1 ]
机构
[1] St Petersburg II Dzhanelidze Res Inst Emergency Me, St Petersburg, Russia
[2] St Petersburg State Univ, St Petersburg, Russia
[3] Interdist Clin Hosp Vsevolozhsk, Vsevolozhsk, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2025年 / 31卷 / 01期
关键词
pertrochanteric fracture; proximal femoral nail; osteosynthesis complications; preoperative planning; intramedullary osteosynthesis; FIXATION; FAILURE; PREDICTORS;
D O I
10.17816/2311-2905-17575
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Despite the high rate of the intramedullary osteosynthesis of proximal femur fractures, the incidence of implant-associated complications exceeds 50%. Poor reduction and incorrect implant positioning significantly increase the risk of mechanical complications and the frequency of unsatisfactory treatment outcomes. The aim of the study was to evaluate various fragment positions after the intramedullary nailing of proximal femur fractures using the developed radiological criteria for assessing the quality of reduction, and to determine the association between the quality of the restoration of the proximal femur, implant position and fracture type. Methods. In a retrospective single-center study we analyzed the primary X-rays of 108 patients with type 31A fractures. Radiological criteria were preliminarily defined. According to them, the position of the fragments and implants was considered satisfactory if the value of the neck-diaphyseal angle was more than 125 degrees, anteversion did not exceed 20 degrees, medial diastasis was not more than 10 mm, and there were no negative medial support, no femoral neck lengthening of more than 10 mm compared with the healthy side, and no penetration of the blade into the joint. Patients were divided into three groups according to the fracture type. We analyzed and compared the proportions of satisfactory and unsatisfactory radiological results within the groups and between them. Results. Satisfactory reduction was noted in 83 patients (76.9%) out of 108, unsatisfactory - in 25 patients (23.1%), and 16 patients (14.8%) had incorrect implant position. Patients with type 31A1 fractures were 3.5 times less likely to have an unsatisfactory reduction than patients with type 31A2 fractures (OR 3.511; 95% CI 1.202-10.261) and 6.7 times less likely to have an unsatisfactory reduction than patients with type 31A3 fractures (OR 6.714; 95% CI 1.685-26.752). The probability of incorrect implant positioning was 6 times higher in type 31A3 fractures than in type 31A1 fractures (OR 6.000; 95% CI 1.410-25.528). Conclusion. To improve the quality of surgical treatment, it is worth paying an increased attention to the quality of the achieved reduction, implant selection, technical peculiarities of the fixation of types A2 and A3 fractures, improvement of preoperative planning algorithms, as well as development of criteria for intraoperative radiological assessment of the quality of the restoration of the proximal femur anatomy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] SURGERY OF PROXIMAL FEMUR FRACTURES WITH TROCHANTERIC NAILING
    BALTENSWEILER, J
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1974, 104 (12) : 421 - 426
  • [2] Intramedullary nailing in pertrochanteric fractures of the proximal femur
    S. J. Ponce
    M. P. Laird
    J. P. Waddell
    European Journal of Trauma and Emergency Surgery, 2014, 40 : 241 - 247
  • [3] Intramedullary nailing in pertrochanteric fractures of the proximal femur
    Ponce, S. J.
    Laird, M. P.
    Waddell, J. P.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2014, 40 (03) : 241 - 247
  • [4] Z-effect after intramedullary nailing systems for trochanteric femur fractures
    S.J.M.Smeets
    G.Kuijt
    P.V.van Eerten
    中华创伤杂志英文版, 2017, 20 (06) : 333 - 338
  • [5] BREAKAGE OF INTRAMEDULLARY NAILING IN TROCHANTERIC, INTERTROCHANTERIC AND SUBTROCHANTERIC FEMUR FRACTURES
    Chitnis, A. S.
    Vanderkarr, M.
    Ruppenkamp, J.
    Holy, C. E.
    Sparks, C.
    VALUE IN HEALTH, 2019, 22 : S677 - S677
  • [6] Clinical results of trochanteric fractures treated with the TARGON® proximal femur intramedullary nailing fixation system
    Kawatani, Yosuke
    Nishida, Kimiaki
    Anraku, Yoshihisa
    Kunitake, Katsuhiko
    Tsutsumi, Yasujiro
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 : S22 - S27
  • [7] CT analysis of femoral malrotation after intramedullary nailing of trochanteric fractures
    Jakub Maléř
    Valér Džupa
    Michal Buk
    Martin Michna
    Jiří Marvan
    Jiří Skála-Rosenbaum
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1865 - 1871
  • [8] CT analysis of femoral malrotation after intramedullary nailing of trochanteric fractures
    Maler, Jakub
    Dzupa, Valer
    Buk, Michal
    Michna, Martin
    Marvan, Jiri
    Skala-Rosenbaum, Jiri
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (08) : 1865 - 1871
  • [9] MECHANICAL COMPLICATIONS ASSOCIATED WITH INTRAMEDULLARY NAILING FOR TROCHANTERIC, INTERTROCHANTERIC AND SUBTROCHANTERIC FEMUR FRACTURES
    Chitnis, A. S.
    Vanderkarr, M.
    Ruppenkamp, J.
    Holy, C. E.
    Sparks, C.
    VALUE IN HEALTH, 2019, 22 : S678 - S678
  • [10] Biomechanical strain analysis of the proximal femur after retrograde intramedullary nailing
    Hak, David J.
    Neiman, Rafael
    Hazelwood, Scott
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (04): : 385 - 389