Left Bundle Branch Pacing in a Pediatric Patient With Tricuspid Valve Replacement for a Complex Ebstein Anomaly

被引:0
|
作者
Tian, Di [1 ]
Jiang, Longfu [1 ]
Shen, Jiabo [1 ]
机构
[1] Ningbo 2 Hosp, Dept Cardiol, Ningbo, Peoples R China
关键词
clinical; electrophysiology-conduction disturbances; implantable devices-physiologic pacing; pediatrics-implantable devices;
D O I
10.1111/anec.70057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This paper presents a unique case of successful implementation of left bundle branch pacing (LBBP) in a pediatric patient with third-degree atrioventricular block following tricuspid valve replacement for a complex Ebstein anomaly. The procedure was performed under real-time recording technique, and resulted in the resolution of the patient's symptoms. This case underscores the feasibility and potential benefits of LBBP in pediatric patients, particularly in those with complex congenital heart conditions and following valve replacement surgery. The successful implementation of LBBP in this case provides valuable insights and a reference for similar cases in the future.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Intracardiac echocardiography-guided left bundle branch pacing in a patient with tricuspid valve replacement
    Vijayaraman, Pugazhendhi
    Panikkath, Ragesh
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2525 - 2527
  • [2] Bioprosthetic Tricuspid Valve Dehiscence in a Patient with Ebstein Anomaly
    Farahani, Maryam Moshkani
    Bagherzadeh, Ataollah
    Salehi, Mehrdad
    TEXAS HEART INSTITUTE JOURNAL, 2009, 36 (05) : 496 - 497
  • [3] EBSTEIN ANOMALY OF THE TRICUSPID VALVE
    WALTON, K
    SPENCER, AG
    JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1948, 60 (03): : 387 - &
  • [4] Cone repair after tricuspid valve replacement in Ebstein anomaly
    Da Fonseca Da Silva, Luciana
    Da Silva, Jose Pedro
    Seese, Laura
    Becerra, Albert F. Guerrero
    Castro-Medina, Mario
    Viegas, Melita
    Morell, Victor O.
    JTCVS TECHNIQUES, 2023, 20 : 150 - 152
  • [5] Left bundle branch pacing from distal His-bundle region by tricuspid valve annulus angiography
    Hu, Yiran
    Gu, Min
    Hua, Wei
    Li, Hui
    Liu, Xi
    Niu, Hongxia
    Zhang, Nixiao
    Zhang, Shu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2550 - 2553
  • [6] Coronary Sinus Ostial Obstruction After Tricuspid Valve Replacement in a Patient With Ebstein's Anomaly
    Lahiri, Subhrajit
    Caldarone, Christopher A.
    Gowda, Srinath T.
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2020, 11 (03) : 350 - 351
  • [7] DEHISCENCE OF A BIOPROSTHETIC TRICUSPID VALVE IN A PATIENT WITH EBSTEIN'S ANOMALY
    Stoute, Heidi
    Swisher, Jordan
    Hassan, Sohail Akhtar
    Schreiber, Theodore L.
    Daher, Edouard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 3771 - 3771
  • [8] Late results of bioprosthetic tricuspid valve replacement in Ebstein's anomaly
    Kiziltan, HT
    Theodoro, DA
    Warnes, CA
    O'Leary, PW
    Anderson, BJ
    Danielson, GK
    ANNALS OF THORACIC SURGERY, 1998, 66 (05): : 1539 - 1544
  • [9] Correction of transcatheter aortic valve replacement induced left bundle branch block by His bundle pacing
    De Pooter, J.
    Calle, S.
    Coeman, M.
    Philipsen, T.
    Gheeraert, P.
    Jordaens, L.
    Kayaert, P.
    Timmermans, F.
    Vanheuverswyn, F.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3733 - 3733
  • [10] THE ELECTROCARDIOGRAM IN EBSTEIN ANOMALY OF THE TRICUSPID VALVE
    VANLINGEN, B
    BAUERSFELD, SR
    AMERICAN HEART JOURNAL, 1955, 50 (01) : 13 - 23