DART-HRMS analysis as a screening method for hallucinogenic mushrooms

被引:0
|
作者
Galhego, Vanessa Braga [1 ]
de Santana, Raquel Capilla Loureiro Alves [1 ]
Bhering, Cecilia de Andrade [1 ]
Antonio, Ananda da Silva [1 ]
Vanini, Gabriela [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, NAF LADETEC, BR-21941598 Rio De Janeiro, RJ, Brazil
关键词
DART; Psilocin; Forensic analysis; Magic mushroom; Triage method; Seized sample; MASS-SPECTROMETRY; PSYCHOACTIVE SUBSTANCES; PSILOCYBIN;
D O I
10.1016/j.forc.2024.100629
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The global drug abuse scene is dynamic. After COVID-19 psilocin-containing mushrooms (PCM) reemerged in the international scenario. To identify illicit drugs, multiple analytical methods must be employed including triage (e.g. colorimetric test) and confirmatory tests (e.g. GC-MS). In addition, in many cases, only samples that give positive results in the triage method are taken to the confirmatory ones. However, colorimetric methods have several drawbacks in the analysis of complex unusual samples, such as the PCM, which can produce falsenegative results. This study evaluated the feasibility of the ambient ionization technique direct analysis in real time - high-resolution mass spectrometry (DART-HRMS) as a triage method for the identification of PCM seized samples. A psilocin standard, edible mushrooms, and 5 seized PCM samples were used to establish the DARTHRMS instrumental setup required for psilocin analysis. The developed DART-HRMS method was compared to the triage method recommended for PCM screening analysis (Erlich's test). While the analysis of psilocin solutions applied 300 V at the DART grid and carrier gas at 150 degrees C, the analysis of solid samples applied 300 V and 375 degrees C. All seized PCM samples presented negative results in Erlich's test, while all of them were positive for psilocin by DART-HRMS. Based on the quality of the HRMS data it was possible to confirm that Erlich's test results were false-negative for the seized samples. DART-HRMS presents itself as a fast, reliable, and trustworthy triage method for the qualitative identification of raw hallucinogenic mushrooms for criminal investigation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Rapid screening for smokeless powders using DART-HRMS and thermal desorption DART-HRMS
    Lennert, Emily
    Bridge, Candice M.
    FORENSIC CHEMISTRY, 2019, 13
  • [2] Rapid screening for smokeless powders using DART-HRMS and thermal desorption DART-HRMS (vol 13, 100148, 2019)
    Lennert, Emily
    Bridge, Candice M.
    FORENSIC CHEMISTRY, 2021, 23
  • [3] Rapid Detection and Quantification of Hallucinogenic Salvinorin A in Commercial Salvia divinorum Products DART-HRMS
    Chambers, Megan I.
    Giffen-Lemieux, Justine E.
    Musah, Rabi A.
    ACS OMEGA, 2022, : 761 - 770
  • [4] Detection of explosives residue using a novel subsampling technique for DART-HRMS analysis
    Estevanes, Jared
    Couch, Alleigh N.
    Bates, Kevin
    Monjardez, Geraldine
    Davidson, J. Tyler
    FORENSIC CHEMISTRY, 2024, 39
  • [5] DART-HRMS/Kendrick mass defect analysis applied to the sourcing of plastic bonded explosives
    Gaiffe, Gabriel
    Cole, Richard
    Bridoux, Maxime
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [6] Optimization of an Untargeted DART-HRMS Method Envisaging Identification of Potential Markers for Saffron Authenticity Assessment
    De Angelis, Elisabetta
    Pilolli, Rosa
    Bejjani, Alice
    Guagnano, Rocco
    Garino, Cristiano
    Arlorio, Marco
    Monaci, Linda
    FOODS, 2021, 10 (06)
  • [7] DART-HRMS reveals metabolic changes of whey through microparticulation and fermentations
    Zacometti, Carmela
    Khazzar, Sara
    Massaro, Andrea
    Tata, Alessandra
    Riuzzi, Giorgia
    Piro, Roberto
    Novelli, Enrico
    Segato, Severino
    Balzan, Stefania
    APPLIED FOOD RESEARCH, 2024, 4 (02):
  • [8] Investigating the capability of UA-DLLME and DART-HRMS in the analysis of benzodiazepines in whole human blood
    Antonio, Ananda da Silva
    Bhering, Cecilia de Andrade
    Wurzler, Gleicielle Tozzi
    Carvalhosa, Diego Rissi
    Jardim, Antonio Celso
    Chalom, Marc Yves
    Neto, Francisco Radler de Aquino
    Vanini, Gabriela
    FORENSIC CHEMISTRY, 2024, 39
  • [9] Rapid identification of the "smart drug" modafinil in suspicious tablets by DART-HRMS combined with micropunching
    Zhou, Liying
    Wang, Xin
    Liu, Wanhui
    Xiang, Ping
    Chen, Hang
    ANALYTICAL METHODS, 2020, 12 (11) : 1430 - 1440
  • [10] Automatic MDSPE Combined with DART-HRMS for the Rapid Quantitation of 21 Synthetic Cathinones in Urine
    Li, Yawen
    Lian, Ru
    Sheng, Zhenhai
    Mao, Jinting
    Mao, Chen
    Liang, Chen
    Zhang, Peng
    Ni, Chunfang
    Wang, Rong
    Zhang, Yurong
    Journal of the American Society for Mass Spectrometry, 2024, 35 (01) : 40 - 49