Evaluation of a rapid lateral flow assay for the detection of taeniosis and cysticercosis at district hospital level in Tanzania: A prospective multicentre diagnostic accuracy study

被引:0
|
作者
Van Damme, Inge [1 ,2 ]
Trevisan, Chiara [1 ,3 ]
Kabululu, Mwemezi [4 ]
Stelzle, Dominik [5 ]
Makasi, Charles E. [6 ,7 ]
Schmidt-Urbaneja, Veronika [5 ]
Mwape, Kabemba E. [8 ]
Mubanga, Chishimba [9 ]
Zulu, Gideon [8 ,10 ]
Moller, Karen Shou [11 ]
Jansen, Famke [12 ]
Reynders, Dries [13 ]
Noh, John [14 ]
Handali, Sukwan [14 ]
Bottieau, Emmanuel [15 ]
Winkler, Andrea S. [5 ,16 ,17 ]
Dorny, Pierre [12 ]
Magnussen, Pascal [18 ]
Gabriel, Sarah [1 ]
Ngowi, Bernard [6 ,19 ]
机构
[1] Univ Ghent, Fac Vet Med, Dept Translat Physiol Infectiol & Publ Hlth, Merelbeke, Belgium
[2] Sciensano, Serv Foodborne Pathogens, Brussels, Belgium
[3] Inst Trop Med, Dept Publ Hlth, Antwerp, Belgium
[4] Tanzania Livestock Res Inst TALIRI, Cent Zone Off, Mpwapwa, Dodoma, Tanzania
[5] Tech Univ Munich, Ctr Global Hlth, Dept Neurol, Munich, Germany
[6] Muhimbili Med Res Ctr, Natl Inst Med Res, Dar Es Salaam, Tanzania
[7] Kilimanjaro Christian Med Univ Coll, Moshi, Tanzania
[8] Univ Zambia, Sch Vet Med, Dept Clin Studies, Lusaka, Zambia
[9] Univ Zambia, Sch Vet Med, Dept Dis Control, Lusaka, Zambia
[10] Gideon Zulu Minist Hlth, Govt Republ Zambia, Lusaka, Zambia
[11] Danish Vet & Food Adm, Glostrup, Denmark
[12] Inst Trop Med, Dept Biomed Sci, Antwerp, Belgium
[13] Univ Ghent, Dept Appl Math Comp Sci & Stat, Ghent, Belgium
[14] Ctr Dis Control & Prevent, Parasit Dis Branch, Div Parasit Dis, Ctr Global Hlth, Atlanta, GA USA
[15] Inst Trop Med, Dept Clin Sci, Antwerp, Belgium
[16] Univ Oslo, Inst Hlth & Soc, Dept Community Med & Global Hlth, Oslo, Norway
[17] Harvard Med Sch, Dept Global Hlth & Social Med, Boston, MA USA
[18] Univ Copenhagen, Fac Hlth & Med Sci, Dept Immunol & Microbiol, Copenhagen, Denmark
[19] Univ Dar Es Salaam, Mbeya Coll Hlth & Allied Sci, Mbeya, Tanzania
来源
PLOS NEGLECTED TROPICAL DISEASES | 2025年 / 19卷 / 03期
关键词
SOLIUM; NEUROCYSTICERCOSIS; TAENIASIS; PREVALENCE; ANTIGENS;
D O I
10.1371/journal.pntd.0012310
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The TS POC test, Taenia solium point-of-care test, is a two-strip lateral flow assay using the recombinant antigen rES33 on the TS POC T test strip, and rT24H on the TS POC CC test strip, to detect antibodies against T. solium taeniosis and cysticercosis, respectively. The objective of this study was to assess the diagnostic performance of the TS POC test for the detection of T. solium taeniosis and cysticercosis in individuals attending district hospitals in Tanzania. In this prospective two-phase diagnostic accuracy study, we recruited participants aged 10 and above, excluding pregnant women and those with acute severe illness. Participants were consecutively recruited in three cohorts according to their signs/symptoms: compatible with neurocysticercosis (cohort 1), intestinal worm infections (cohort 2), and other signs/symptoms (cohort 3). Lacking a gold standard test for both infections, diagnostic accuracy was evaluated using results of two coprological and two serological tests for taeniosis, and three serological tests for cysticercosis, in a Bayesian Latent Class Model approach. The TS POC test was conducted on 601 participants in cohort 1, 1661 participants in cohort 2, and 662 participants in cohort 3. Most individuals tested negative on both TS POC test strips, with proportions of 83% (n = 496), 97% (n = 1613) and 97% (n = 641) in cohorts 1, 2 and 3, respectively. Complete case data were available for 120, 114, and 53 participants for taeniosis, and 126, 122, and 55 participants for cysticercosis. Sensitivity values for the TS POC T test strip were 50.2% [95% credible interval 4.9 - 96.4], 40.8% [2.2 - 95.2], and 40.4% [2.3 - 95.0], while specificity values were 98.6% [97.1 - 99.6], 99.3% [98.7 - 99.7] and 99.4% [98.5 - 99.9], respectively. For the TS POC CC test strip, the sensitivity was 77.5% [37.8 - 99.2], 24.9% [95% CI 6.4 - 52.7] and 44.2% [6.6 - 91.5], and the specificity 92.3% [86.5 - 98.8], 99.1% [97.8 - 100], and 98.1% [96.1 - 99.7] across the respective cohorts. Although the TS POC test has a low sensitivity, it demonstrates a high specificity, which may have clinical utility to guide treatment and diagnostic decisions, or in epidemiological studies. An important strength of this study lies in its assessment of the TS POC test under real-world conditions, revealing divergent estimates across distinct cohorts. The study underscores the suboptimal performance of existing tests under field conditions, emphasizing the need to enhance and validate these tests for better performance in practical real-world settings.Registration number: PACTR201712002788898.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Evaluation of lateral flow immunochromatographic assay for diagnostic accuracy of cryptococcosis
    Li-Min Xie
    Geng-Ling Lin
    Hao-Neng Dong
    Ying-Xia Liao
    Ye-Ling Liu
    Jian-Feng Qin
    Xu-Guang Guo
    BMC Infectious Diseases, 20
  • [2] Evaluation of lateral flow immunochromatographic assay for diagnostic accuracy of cryptococcosis
    Xie, Li-Min
    Lin, Geng-Ling
    Dong, Hao-Neng
    Liao, Ying-Xia
    Liu, Ye-Ling
    Qin, Jian-Feng
    Guo, Xu-Guang
    BMC INFECTIOUS DISEASES, 2020, 20 (01)
  • [3] Trial Design of a Prospective Multicenter Diagnostic Accuracy Study of a Point-of-Care Test for the Detection of Taenia solium Taeniosis and Neurocysticercosis in Hospital-Based Settings in Tanzania
    Trevisan, Chiara
    Damme, Inge
    Ngowi, Bernard
    Schmidt, Veronika
    Stelzle, Dominik
    Moller, Karen
    Kabululu, Mwemezi
    Makasi, Charles
    Magnussen, Pascal
    Bottieau, Emmanuel
    Abatih, Emmanuel
    Johansen, Maria
    Ngowi, Helena
    Ndawi, Benedict
    Mwape, Kabemba
    Zulu, Gideon
    Dorny, Pierre
    Winkler, Andrea
    Gabriel, Sarah
    DIAGNOSTICS, 2021, 11 (09)
  • [4] Diagnostic accuracy of Lipoarabinomannan detection by lateral flow assay in pleural tuberculosis
    Mohapatra, Atish
    Gaikwad, Ujjwala
    Ganga, Ranganath T.
    Sharma, Pratibha
    BMC INFECTIOUS DISEASES, 2024, 24 (01)
  • [5] Diagnostic accuracy of Lipoarabinomannan detection by lateral flow assay in pleural tuberculosis
    Atish Mohapatra
    Ujjwala Gaikwad
    Ranganath T. Ganga
    Pratibha Sharma
    BMC Infectious Diseases, 24
  • [6] A Prospective Hospital Study to Evaluate the Diagnostic Accuracy of Rapid Diagnostic Tests for the Early Detection of Leptospirosis in Laos
    Dittrich, Sabine
    Boutthasavong, Latsaniphone
    Keokhannhoung, Dala
    Phuklia, Weerawat
    Craig, Scott B.
    Tulsiani, Suhella M.
    Burns, Mary-Anne
    Weier, Steven L.
    Dance, David A. B.
    Davong, Viengmon
    Vongsouvath, Manivanh
    Mayxay, Mayfong
    Phetsouvanh, Rattanaphone
    Newton, Paul N.
    Woods, Kate
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 98 (04): : 1056 - 1060
  • [7] PRe-hospital Evaluation of Sensitive TrOponin (PRESTO) Study: multicentre prospective diagnostic accuracy study protocol
    Alghamdi, Abdulrhman
    Cook, Eloise
    Carlton, Edward
    Siriwardena, Aloysius
    Hann, Mark
    Thompson, Alexander
    Foulkes, Angela
    Phillips, John
    Cooper, Jamie
    Bell, Steve
    Kirby, Kim
    Rosser, Andy
    Body, Richard
    BMJ OPEN, 2019, 9 (10):
  • [8] Evaluation of Lateral-Flow Assay for Rapid Detection of Influenza Virus
    Han, Meng-Yi
    Xie, Tian-Ao
    Li, Jia-Xin
    Chen, Hui-Jin
    Yang, Xiao-Hui
    Guo, Xu-Guang
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [9] Evaluation of the diagnostic accuracy of UBC® Rapid in bladder cancer: a Swedish multicentre study
    Styrke, Johan
    Henriksson, Helene
    Ljungberg, Borje
    Hasan, Mudhar
    Silfverberg, Ingrid
    Einarsson, Roland
    Malmstrom, Per-Uno
    Sherif, Amir
    SCANDINAVIAN JOURNAL OF UROLOGY, 2017, 51 (04) : 293 - 300
  • [10] Evaluation of a new enzyme-immunodot assay for AQP4-IgG for large-scale rapid use: a prospective multicentre diagnostic accuracy study
    Bi, Jin
    Fu, Ying
    MULTIPLE SCLEROSIS JOURNAL, 2023, 29 (07) : NP1 - NP1