Investigating the Impact of Voxel Size and Postfiltering on Quantitative Analysis of Positron Emission Tomography/Computed Tomography: A Phantom Study

被引:1
|
作者
Mohymen, Ahmed Abdel [1 ]
Farag, Hamed Ibrahim [1 ]
Reda, Sameh M. [2 ]
Monem, Ahmed Soltan [3 ]
Ali, Said A. [3 ]
机构
[1] Cairo Univ, Natl Canc Inst, Dept Nucl Med & Radiat Therapy, Giza, Egypt
[2] Natl Inst Stand, Dept Radiometry, Giza, Egypt
[3] Cairo Univ, Dept Biophys, Fac Sci, Giza, Egypt
关键词
Gibbs artefact; partial volume effects; point spread function; postfiltering; time of flight; voxel size; TIME-OF-FLIGHT; POINT-SPREAD FUNCTION; PET/CT; RECONSTRUCTION; QUANTIFICATION; OPTIMIZATION; NOISE; PSF; RESOLUTION; ARTIFACTS;
D O I
10.4103/jmp.jmp_123_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: This study aims to investigate the influence of voxel size and postfiltering on the quantification of standardized uptake value (SUV) in positron emission tomography/computed tomography (PET/CT) images. Materials and Methods: National Electrical Manufacturers Association phantom with the spheres of different sizes were utilized to simulate the lesions. The phantom was scanned using a PET/CT scanner, and the acquired images were reconstructed using two different matrix sizes, (192 x 192) and (256 x 256), and a wide range of postfiltering values. Results: The findings demonstrated that postfiltering significantly affected SUV measurements. The changes in postfiltering values can result in overestimation or underestimation of SUV values, highlighting the importance of carefully selecting appropriate filters. Increasing the matrix size improved SUVmax and SUVmean values, particularly for small-sized spheres. Smaller voxel reconstructions slightly reduced partial volume effects and partially enhanced SUV quantification. Conclusions: Careful consideration of postfiltering values and matrix size selection can lead to better SUV quantification. These findings emphasize the need to optimize the reconstruction parameters to enhance the clinical utility of PET/CT in detecting and evaluating malignant lesions.
引用
收藏
页码:597 / 607
页数:11
相关论文
共 50 条
  • [1] Comparison of dedicated breast positron emission tomography and whole-body positron emission tomography/computed tomography images: a common phantom study
    Yoko Satoh
    Utaroh Motosugi
    Masamichi Imai
    Hiroshi Onishi
    Annals of Nuclear Medicine, 2020, 34 : 119 - 127
  • [2] Comparison of dedicated breast positron emission tomography and whole-body positron emission tomography/computed tomography images: a common phantom study
    Satoh, Yoko
    Motosugi, Utaroh
    Imai, Masamichi
    Onishi, Hiroshi
    ANNALS OF NUCLEAR MEDICINE, 2020, 34 (02) : 119 - 127
  • [3] Size-dependent thresholding as an optimal method for tumor volume delineation on positron emission tomography computed tomography: A Phantom study
    Gupta, Arun
    Sharma, Punit
    Patel, Chetan D.
    Maharjan, Sagar
    Pandey, Anil
    Kumar, Rakesh
    Malhotra, Arun
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2011, 26 (01): : 22 - 26
  • [4] Positron emission tomography/computed tomography
    Townsend, David W.
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 152 - 166
  • [5] Visualization with positron emission tomography, computed tomography, magnetic resonance imaging, positron emission tomography/computed tomography, and positron emission tomography/magnetic resonance imaging
    Seemann, MD
    Gaa, J
    CIRCULATION, 2005, 112 (21) : E329 - E330
  • [6] EFFECT OF OBJECT SIZE IN QUANTITATIVE POSITRON COMPUTED TOMOGRAPHY
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 683 - 683
  • [7] Positron emission tomography computed tomography in oncology
    Drake, Brent
    Cook, Gary J. R.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2011, 72 (11) : 631 - 637
  • [8] Positron Emission Tomography/Computed Tomography in Melanoma
    Bourgeois, Austin C.
    Chang, Ted T.
    Fish, Lindsay M.
    Bradley, Yong C.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2013, 51 (05) : 865 - +
  • [9] Positron emission tomography/computed tomography in rheumatology
    Derlin, T.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2017, 76 (07): : 566 - 573
  • [10] Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography
    Pan, Tinsu
    Zaidi, Habib
    PET CLINICS, 2013, 8 (01) : 37 - +