Automatic Generation of Pipe Routing for Variable Refrigerant Flow Air Conditioning System

被引:0
|
作者
Dong, Liyan [1 ]
Lin, Bo [2 ,3 ]
Jiang, Yu [2 ]
Wang, Weixiang [1 ]
Zhang, Yake [1 ]
Gu, Jiefan [1 ]
Xu, Peng [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] GuangDong Midea HVAC Equipment Co Ltd, Foshan, Peoples R China
[3] Shunde Polytech, Sch Design, Foshan, Peoples R China
来源
关键词
Refrigerant piping; Automatic; Obstacle avoidance; Ant colony optimization; ANT COLONY OPTIMIZATION; ALGORITHM;
D O I
10.1016/j.jobe.2024.111755
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The traditional design of variable refrigerant flow (VRF) air conditioning system relies heavily on the expertise and experience of designers. Designers spend considerable time modifying the drawings to accommodate design alternations. This paper aims to develop an automated routing method for refrigerant piping in VRF systems, based on building information modeling (BIM). The proposed methodology includes automatic zoning of the VRF system, automatic layout of indoor units, and automatic generation of refrigerant piping. To achieve system zoning, a combination of hierarchical clustering and rule-based methods are employed, while a geometric recognition method is utilized for the obstacle-avoiding layout of the indoor units. The escape graph method is applied for spatial modeling, and an ant colony optimization (ACO) approach with a concurrent search strategy is applied for multi-objective path optimization. This approach facilitates the automatic generation of the optimal orthogonal branch pipe route while ensuring obstacle avoidance. Moreover, a breadth-first search (BFS) approach is employed, considering 12 potential forms of divergence tube connections within the pipeline, which are sequentially integrated into the pre-generated piping layout. This paper presents the results of testing conducted on two engineering buildings modeled in Revit. The outcomes align with engineering standards, thus demonstrating the feasibility of the proposed method. Compared to traditional manual drafting, this automated method can complete the piping layout in just a few seconds, significantly reducing design and drawing time. This advancement further enhances the level of intelligence and automation in the heating, ventilation, and air conditioning (HVAC) system design.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] EXERGY ANALYSIS OF THE PERFORMANCE OF A VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONING SYSTEM
    Padilla, Miguel
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 57 - 68
  • [2] Determination criterion of defrosting condition for variable refrigerant flow air conditioning system
    Tu, Qiu
    Xu, Jingqiang
    Feng, Yuhai
    Mao, Shoubo
    Guo, Defang
    He, Jianqi
    ENERGY AND BUILDINGS, 2012, 48 : 61 - 70
  • [3] A machine learning bayesian network for refrigerant charge faults of variable refrigerant flow air conditioning system
    Hu, Min
    Chen, Huanxin
    Shen, Limei
    Li, Guannan
    Guo, Yabin
    Li, Haorong
    Li, Jiong
    Hu, Wenju
    ENERGY AND BUILDINGS, 2018, 158 : 668 - 676
  • [4] Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Fang, Xing
    Du, Zhimin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 14 - 25
  • [5] A hybrid control strategy for frequency regulation with variable refrigerant flow air conditioning system
    Zhou, Fenglin
    Li, Yaoyu
    Dong, Liujia
    ENERGY AND BUILDINGS, 2024, 303
  • [6] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [7] Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    APPLIED THERMAL ENGINEERING, 2015, 80 : 87 - 96
  • [8] Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system
    Tu, Qiu
    Mao, Shoubo
    Feng, Yuhai
    Guo, Defang
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2542 - 2554
  • [9] Effects of sub-cooler on cooling performance of variable refrigerant flow air conditioning system
    Tu, Qiu
    Zhang, Lina
    Cai, Wei
    Guo, Xiujuan
    Deng, Chenmian
    Zhang, Jie
    Wang, Bingjun
    APPLIED THERMAL ENGINEERING, 2017, 127 : 1152 - 1163
  • [10] Variable refrigerant flow air conditioning system applicant company selection using PROMETHEE method
    Abaci, Nejla
    Ic, Yusuf Tansel
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2022, 13 (04) : 1177 - 1204