Performance investigation of multi-functional series-connected building-integrated photovoltaic/thermal system and analysis of its multi-objective optimization design strategy

被引:0
|
作者
Qian, Yu [1 ]
Ji, Jie [1 ]
Xie, Hao [1 ]
Jia, Hengmin [2 ]
Meng, Hongju [1 ]
Li, Jiyao [1 ]
Mu, Yan [2 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Affiliated Hosp USTC 1, Dept Infect Control, Div Life Sci & Med, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal inactivation; Series connection; BIPVT; Muti-objective optimization; TROMBE WALL; EXPERIMENTAL VALIDATION; INACTIVATION; TECHNOLOGY; SIMULATION; COLLECTOR;
D O I
10.1016/j.buildenv.2024.112126
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The series-connected building-integrated photovoltaic/thermal (BIPVT) system can significantly increase the terminal temperature and achieve both power generation and heating. However, its utilization of thermal energy is limited. Airborne infectious diseases threaten indoor occupant health. Pathogenic microorganisms can be thermally inactivated, and the effectiveness of inactivation is positively correlated with exposure temperature and duration. Therefore, series-connected BIPVT system has the potential for air thermal disinfection. Based on this, a multifunctional series-connected BIPVT system that provides heating, power generation, and air purification is proposed. However, these three outputs conflict with each other, and there is a lack of optimized design strategies to maximize the system's overall output. In response, this paper develops a multi-objective optimization strategy for the system and optimizes its design across different climate zones. The main content is as follows: (1) Compared with single-stage systems, series systems can significantly improve air purification performance. The series-connected BIPVT system with the best air purification effect can increase the single-pass inactivation ratio to 100 % under the irradiance of 600 W/m(2) (2) The glazed photovoltaic/thermal-glazed solar thermal system has the best thermal performance and air purification performance, the thermal efficiency is 38.1 % and the clean air delivery rate is 98.6 m(3)/h under the irradiance of 800 W/m(2) (3) Compared to single-objective optimization and non-optimized designs, the multi-objective optimization design achieves the highest technique for order of preference similarity to the ideal solution (TOPSIS) score, which is 0.5968.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Scenario-Based Multi-Objective Optimization of an Air-Based Building-Integrated Photovoltaic/Thermal System
    Khaki, Mahsa
    Shahsavar, Amin
    Khanmohammadi, Shoaib
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (01):
  • [2] Multi-objective optimization of building-integrated microalgae photobioreactors for energy and daylighting performance
    Talaei, Maryam
    Mahdavinejad, Mohammadjavad
    Azari, Rahman
    Prieto, Alejandro
    Sangin, Hamed
    JOURNAL OF BUILDING ENGINEERING, 2021, 42
  • [3] Multi-objective optimization and evaluation of the building-integrated photovoltaic/thermal-energy pile ground source heat pump system
    Wang, Fang
    You, Tian
    Cui, Hongzhi
    APPLIED ENERGY, 2024, 371
  • [4] Multi-objective optimization of building integrated photovoltaic windows in office building
    Qiao, Xinyu
    Zhao, Tianyi
    Zhang, Xingxing
    Li, Yu
    ENERGY AND BUILDINGS, 2024, 318
  • [5] Multi-objective optimization of building integrated photovoltaic solar shades
    Sadatifar, Seyedsoroush
    Johlin, Eric
    SOLAR ENERGY, 2022, 242 : 191 - 200
  • [6] A multi-objective optimization framework for building-integrated PV envelope design balancing energy and cost
    Samarasinghalage, Tharushi I.
    Wijeratne, W. M. Pabasara U.
    Yang, Rebecca J.
    Wakefield, Ron
    JOURNAL OF CLEANER PRODUCTION, 2022, 342
  • [7] Energy and exergy analysis and multi-objective optimization of an air based building integrated photovoltaic/thermal (BIPV/T) system
    Khaki, Mahsa
    Shahsavar, Amin
    Khanmohammadi, Shoaib
    Salmanzadeh, Mazyar
    SOLAR ENERGY, 2017, 158 : 380 - 395
  • [8] Optimal Photovoltaic System Design with Multi-Objective Optimization
    Ibrahim, Amin
    Bourennani, Farid
    Rahnamayan, Shahryar
    Naterer, Greg F.
    INTERNATIONAL JOURNAL OF APPLIED METAHEURISTIC COMPUTING, 2013, 4 (04) : 63 - 89
  • [9] Multi-objective 4E analysis for a building integrated photovoltaic thermal double skin Facade system
    Shakouri, Mahdi
    Ghadamian, Hossein
    Hoseinzadeh, Siamak
    Sohani, Ali
    SOLAR ENERGY, 2022, 233 : 408 - 420
  • [10] Performance evaluation and multi-objective optimization of a hybrid earth-air heat exchanger and building-integrated photovoltaic/thermal system with phase change material and exhaust air heat recovery
    Shahsavar, Amin
    Azimi, Neda
    JOURNAL OF BUILDING ENGINEERING, 2024, 90