Diagnostic accuracy of point-of-care ultrasound of the posterior fatpad in elbow fractures

被引:0
|
作者
Haak, Svenja L. [1 ,2 ]
van der Veen, Thea [1 ]
Stolmeijer, Renate [2 ]
Boendermaker, Annemieke E. [3 ]
van der Kolk, Brigitta Y. M. [4 ]
ter Maaten, Jan C. [2 ]
Ter Avest, Ewoud [2 ,5 ]
Lameijer, Heleen [1 ]
机构
[1] Med Ctr Leeuwarden, Dept Emergency Med, Leeuwarden, Netherlands
[2] Univ Med Ctr Groningen, Dept Acute Care, Groningen, Netherlands
[3] Tjongerschans Hosp Heerenveen, Dept Emergency Med, Heerenveen, Friesland, Netherlands
[4] Isala, Dept Emergency Med, Zwolle, Overijssel, Netherlands
[5] Londons Air Ambulance & Barts Hlth NHS Trust, Royal London Hosp, London, England
关键词
fractures and dislocations; ultrasonography; trauma; extremity; COMPUTED-TOMOGRAPHY; TRAUMA; ULTRASONOGRAPHY; CHILDREN; ADULTS;
D O I
10.1136/emermed-2024-214448
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Point-of-care ultrasound (POCUS) can potentially be used in the triage of patients with elbow injuries. However, the diagnostic accuracy of POCUS performed by non-radiologists for the exclusion of elbow fractures is yet unknown. This study aimed to investigate the diagnostic potential of POCUS of the posterior fatpad performed by non-radiologists in the workup of adult patients presenting with elbow injuries.Methods A multicentre, prospective cohort study was conducted between January 2021 and August 2022 in four EDs to determine the diagnostic accuracy of an elevated posterior fatpad on POCUS to demonstrate or exclude an elbow fracture in patients presenting with elbow injuries to the ED. The study population consisted of a convenience sample. In patients >= 16 years of age with an elbow injury for which an X-ray was ordered, POCUS was performed by emergency physicians trained in ultrasound. POCUS (index test) results were compared with X-ray outcomes (reference standard) to determine the diagnostic accuracy of POCUS.Results A total of 215 patients were included, 143 (67%) of whom had a fracture confirmed on X-ray. POCUS was positive based on a visualised elevated posterior fatpad in 127 (59%) patients. An elevated posterior fatpad on POCUS had a sensitivity of 91% (95% CIs 85% to 95%), a specificity of 93% (95% CI 85% to 98%), a negative likelihood ratio of 0.10 (95% CI 0.06 to 0.16) and a positive likelihood ratio of 13.09 (95% CI 5.61 to 30.54) for the presence of an elbow fracture. Post hoc review of the images by expert sonographers improved sensitivity to 96% (95% CI 91% to 99%).Conclusion POCUS of the posterior fatpad is a promising adjunct to physical examination to determine the need for further diagnostic studies in the triage of patients with elbow injuries. Sensitivity after a limited training is high, but not perfect, and can likely further be improved with additional training.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Accuracy of point-of-care ultrasound for diagnosis of elbow fractures in children
    Joni E Rabiner
    H Khine
    JR Avner
    LM Friedman
    JW Tsung
    Critical Ultrasound Journal, 4 (Suppl 1)
  • [2] Diagnostic accuracy of point-of-care ultrasound in detecting clavicle fractures
    Haak, Svenja L.
    Rietveld, Vincent
    Vos, Hendrika
    Kroon, Tineke
    Borgstede, Marion G.
    Boendermaker, Annemieke E.
    Rosendaal, Arthur
    Lameijer, Heleen
    Maaten, Jan C. Ter
    Stolmeijer, Renate
    ter Avest, Ewoud
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2025, 88 : 156 - 161
  • [3] The accuracy of point-of-care ultrasound as a diagnostic tool for patella fractures
    Kilic, Turgay Yilmaz
    Yesilaras, Murat
    Atilla, Ozge Duman
    Turgut, Ali
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (08): : 1576 - 1578
  • [4] Diagnostic Accuracy of Point-of-Care Gastric Ultrasound
    Kruisselbrink, Richelle
    Gharapetian, Angineh
    Chaparro, Luis E.
    Ami, Noam
    Richler, Dustin
    Chan, Vincent W. S.
    Perlas, Anahi
    ANESTHESIA AND ANALGESIA, 2019, 128 (01): : 89 - 95
  • [5] Accuracy of Point-of-Care Ultrasonography for Diagnosis of Elbow Fractures in Children
    Rabiner, Joni E.
    Khine, Hnin
    Avner, Jeffrey R.
    Friedman, Lana M.
    Tsung, James W.
    ANNALS OF EMERGENCY MEDICINE, 2013, 61 (01) : 9 - 17
  • [6] Accuracy of Point-of-Care Ultrasound for Diagnosis of Skull Fractures in Children
    Rabiner, Joni E.
    Friedman, Lana M.
    Khine, Hnin
    Avner, Jeffrey R.
    Tsung, James W.
    PEDIATRICS, 2013, 131 (06) : E1757 - E1764
  • [7] DIAGNOSTIC ACCURACY OF POINT-OF-CARE GASTRIC ULTRASOUND: A BAYESIAN ANALYSIS
    Chaparro, Luis E.
    Kruisselbrink, Richelle
    Gharapetian, Angineh
    Ami, Noam
    Richler, Dustin
    Chan, Vincent W.
    Perlas, Anahi
    ANESTHESIA AND ANALGESIA, 2018, 126 (04): : 736 - 737
  • [8] ACCURACY OF POINT-OF-CARE ULTRASOUND IN DETECTING FRACTURES IN CHILDREN: A VALIDATION STUDY
    Caroselli, Costantino
    Raffaldi, Irene
    Norbedo, Stefania
    Parri, Niccolo
    Poma, Francesca
    Blaivas, Michael
    Zaccaria, Eleonora
    Dib, Giovanni
    Fiorentino, Romano
    Longo, Daniele
    Biban, Paolo
    Urbino, Antonio Francesco
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (01): : 68 - 75
  • [9] The accuracy of point-of-care ultrasound to diagnose long bone fractures in the ED
    Waterbrook, Anna L.
    Adhikari, Srikar
    Stolz, Uwe
    Adrion, Carrie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (09): : 1352 - 1356
  • [10] Rapid screening for the posterior fat pad sign in suspected pediatric elbow fractures using point-of-care ultrasound: A "FAST exam" for the traumatized elbow
    Tsung J.W.
    Blaivas M.
    Critical Ultrasound Journal, 2010, 1 (3) : 111 - 116