An FBG-based method for load measurement of a cylindrical rolling element bearing

被引:0
|
作者
Wang, Xin [1 ]
Liang, Xihui [1 ]
Wu, Nan [1 ]
机构
[1] Univ Manitoba, Dept Mech Engn, Winnipeg, MB R3T 5V6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
cylindrical roller bearing; load measurement; contact force; strain; FBG sensor; STATIC CAPACITY; ROLLER BEARING; BALL;
D O I
10.1088/1361-6501/ad8bec
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Contact forces between raceways and rolling elements of a bearing stand as crucial operational aspects defining the bearing's performance. While monitoring bearing load through load cells or strain gauges on the shaft or housing is feasible, it may not precisely reflect the distributed load transmitted by the rollers directly to the raceways. This paper introduces a method to calculate these contact forces, relying on a linear assumption correlating the loads to the measured strains on the outer race of a bearing. In our research, we conducted both static and dynamic tests on cylindrical roller bearings through simulations and experiments. We designed an experimental test rig to conduct both static and dynamic experiments and utilized FBG optical fiber sensors for contact force measurement in bearings due to their multiple advantages, including high sensitivity, resistance to corrosion and magnetic interference, and ease of installation on the bearing outer race due to their shape and size. Our findings indicate a consistent linear relationship between contact forces and strains measured on the bearing's outer race. Furthermore, we calculated the linear coefficient K values from three test groups: static tests under simulation study, static tests under experimental study, and dynamic tests under experimental study. The K values obtained from static tests (simulation and experimental studies) and dynamic tests (experimental study) align consistently. Following this, we calculated contact forces in both static and dynamic experiments by multiplying the measured strains with K . Our calculations resulted in an error percentage of less than 2% for static tests and below 5% for dynamic tests, highlighting the accuracy of our approach in determining these contact forces.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] FBG-based sensors for measurement of small distances
    Benson, Trevor
    Palmowski, Jacek
    Phang, Sendy
    Anuszkiewicz, Alicja
    Osuch, Tomasz
    Zhang, Yaping
    Berei-Pawlik, Elibieta
    2024 24TH INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS, ICTON 2024, 2024,
  • [2] FBG-Based Positioning Method for BOTDA Sensing
    Li, Jianzhi
    Xu, Longxiang
    Kishida, Kinzo
    IEEE SENSORS JOURNAL, 2016, 16 (13) : 5236 - 5242
  • [3] Long-term monitoring FBG-based cable load sensor
    Zhang, Zhichun
    Zhou, Zhi
    Wang, Chuan
    Ou, Jinping
    SMART STRUCTURES AND MATERIALS 2006: SMART SENSOR MONITORING SYSTEMS AND APPLICATIONS, 2006, 6167
  • [4] Three-dimensional simulation of rolling element load in a combined loaded cylindrical roller bearing
    Predki, Wolfgang
    Koch, Oliver
    Proceedings of the International Conference on Mechanical Transmissions, Vols 1 and 2, 2006, : 679 - 684
  • [5] STIFFNESS OPTIMIZATION OF HOLLOW CYLINDRICAL ROLLING ELEMENT BEARING
    Darji, P. H.
    Vakharia, D. P.
    PROCEEDINGS OF THE STLE/ASME INTERNATIONAL JOINT TRIBOLOGY CONFERENCE 2008, 2009, : 423 - 426
  • [6] FBG-Based Loosening Angle Measurement Sensor for Bolt Looseness Monitoring
    Zhang, Wenxin
    Wang, Tao
    Yu, Wei
    Deng, Shaohua
    Xiao, Yunke
    Lu, Guangtao
    IEEE SENSORS JOURNAL, 2025, 25 (03) : 4254 - 4260
  • [7] FBG-based Non-contact Vibration Measurement and Experimental Study
    Wei, Li
    Zhou, Zu-De
    Huang, Jun
    Tan, Yue-Gang
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (09) : 1577 - 1581
  • [8] FBG-based non-contact vibration measurement and experimental study
    Li Wei
    Zu-De Zhou
    Jun Huang
    Yue-Gang Tan
    International Journal of Precision Engineering and Manufacturing, 2013, 14 : 1577 - 1581
  • [9] Development of an FBG-Based Wearable Sensor for Simultaneous Respiration and Heartbeat Measurement
    Shi, Chaoyang
    Tang, Zhongxin
    Zhang, Han
    Liu, Yuhong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [10] A model-based local fault size measurement method of rolling bearing considering load influence
    Liu, Chang
    Cheng, Gang
    Chen, Xihui
    Li, Yong
    Gu, Wei
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (15) : 3335 - 3346