The Personal Glucose Meter as the Measurement Principle in Point-of-Care Applications

被引:0
|
作者
Cano, Monica [1 ]
del Valle, Manel [1 ]
机构
[1] Univ Autonoma Barcelona UAB, Dept Chem, Sensors & Biosensors Grp, Edif Cn, Bellaterra 08193, Barcelona, Spain
来源
BIOSENSORS-BASEL | 2025年 / 15卷 / 02期
关键词
glucose biosensor; point-of-care; aptamer; antibody; invertase enzyme label; QUANTITATIVE DETECTION; GLUCOMETER READOUT; SENSITIVE DETECTION; PORTABLE DETECTION; IMMUNOASSAY; BIOSENSORS; INVERTASE; APTAMER; SENSORS; DIAGNOSTICS;
D O I
10.3390/bios15020121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A personal glucose meter (PGM) is a medical device that measures blood glucose levels and can be found worldwide. Owing to their sensitivity, simplicity, portability, and low cost, PGMs stand as one of the most frequently utilized analytical methods. This work reviews the different applied methodologies for detecting analytes other than glucose employing a PGM and how it can be incorporated for point-of-care diagnosis needs. To visualize the variants, first, a classification is made according to the biorecognition elements used (aptamers, antibodies, etc.), and where the determination of different analytes is done through the glucose signal using different glucose-generating enzymes such as invertase or glucosidase. Transduction can also be based on the use of nanocarriers that generally encapsulate glucose, although it is also possible to find a combination of the two aforementioned strategies. The PGM can also be used for the direct detection of interfering substances of the biosensor, such as NADH or paracetamol. Lastly, we discuss how a PGM might have been implemented to detect COVID-19 and how it could be used on a massive scale for the point-of-care diagnosis of a pandemic.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Accuracy of the point-of-care glucose meter for use in calves
    Nishi, Yasunobu
    Murakami, Yoshiki
    Otsuka, Marina
    Tsukano, Kenji
    Ajito, Tadaharu
    Suzuki, Kazuyuki
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2019, 81 (09): : 1301 - 1304
  • [2] The accuracy of point-of-care glucose measurement
    O'Kane, Maurice J.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 108 - 109
  • [3] Point-of-care detection of Microcystin-LR with a personal glucose meter in drinking water source
    Lifang Zhao
    Long Teng
    Juan Zhang
    He Li
    Chinese Chemical Letters, 2019, 30 (05) : 1035 - 1037
  • [4] Point-of-care testing of protein biomarkers by integrating a personal glucose meter with a concatenated DNA amplifier
    Shi, Hai
    Zheng, Ji
    Wang, Yanxia
    Zhu, Sha
    Xiang, Yang
    Zhu, Xiaoli
    Li, Genxi
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 322
  • [5] Point-of-care detection of Microcystin-LR with a personal glucose meter in drinking water source
    Zhao, Lifang
    Teng, Long
    Zhang, Juan
    Li, He
    CHINESE CHEMICAL LETTERS, 2019, 30 (05) : 1035 - 1037
  • [6] Point-of-care testing of methotrexate using a controlled release sensor based on a personal glucose meter
    Yang, Liyu
    Yang, Siyi
    Zhang, Ting
    Zhao, Langyi
    Fa, Huanbao
    Wang, Yongzhong
    Huo, Danqun
    Hou, Changjun
    Yang, Mei
    ANALYTICAL METHODS, 2025, 17 (06) : 1345 - 1353
  • [7] Sensitive point-of-care monitoring of cardiac biomarker myoglobin using aptamer and ubiquitous personal glucose meter
    Wang, Qing
    Liu, Fang
    Yang, Xiaohai
    Wang, Kemin
    Wang, Hui
    Deng, Xin
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 161 - 164
  • [8] Point-of-care monitoring of intracellular glutathione and serum triglyceride levels using a versatile personal glucose meter
    Xu, Jinqiong
    Qiao, Xiujuan
    Zhang, Jingjing
    Cheng, Ni
    Sheng, Qinglin
    Zheng, Jianbin
    Cao, Wei
    Yue, Tianli
    Lu, Yi
    ANALYTICAL METHODS, 2019, 11 (14) : 1849 - 1856
  • [9] Glucose point-of-care meter operators competency: An assessment checklist
    Friesner, Cindy Tang
    Meyer, Julien
    Nippak, Pria
    PRACTICAL LABORATORY MEDICINE, 2020, 20
  • [10] Blood glucose: Measurement in the point-of-care setting
    Kiechle, FL
    Main, RI
    LABORATORY MEDICINE, 2000, 31 (05) : 276 - 282