Evaluation of the energy efficiency of the first DC defibrillators

被引:0
|
作者
Gorbunov, B. B. [1 ,2 ]
Gusev, A. N. [3 ]
Selishchev, S. V. [1 ]
Vostrikov, V. A. [4 ]
机构
[1] MIET Natl Res Univ, Inst Biomed Syst, Zelenograd, Moscow, Russia
[2] IM Sechenov First Moscow State Med Univ, Sechenov Univ, Ctr Digital Biodesign & Personalized Healthcare, Russian Minist Hlth, Moscow, Russia
[3] Metrax GmbH, Rottweil, Germany
[4] OOO Zelenograd Med Equipment Innovat & Technol Ctr, Zelenograd, Moscow, Russia
关键词
D O I
10.1007/s10527-024-10430-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article addresses the characteristics of the first mass-produced DC defibrillators: the ID-1-VEI (USSR), Prema (Czechoslovak Socialist Republic), and the Cardioverter (USA). Data obtained by simulation cardiomyocyte reactions in the state of simulated fibrillation to the depolarizing pulses delivered by these defibrillators at load impedance values of 25, 50, and 100 Omega were plotted to identify relationships between the fraction of the fibrillation cycle at which the defibrillation pulse causes a long-term extension of the refractory period of the cardiomyocyte (the defibrillation completeness index) and the relative energy of the defibrillation pulse. Results obtained from simulation defibrillator pulses at a load impedance of 25 Omega demonstrated greater energy efficiency for pulses from the Prema defibrillator, presumably associated with the large amplitude of the multiple pulse phases.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF ENERGY EFFICIENCY OF USE OF ENERGY STORAGE FOR DC LOCOMOTIVES
    Nezevak, V. L.
    Shatokhin, A. P.
    CONSTRUCTION AND MAINTENANCE OF RAILWAY INFRASTRUCTURE IN COMPLEX ENVIRONMENT, 2014, : 473 - 476
  • [2] COMPARATIVE EVALUATION OF SOME DC CARDIAC DEFIBRILLATORS
    BALAGOT, RC
    BANDELIN, VR
    AMERICAN HEART JOURNAL, 1969, 77 (04) : 489 - &
  • [3] FIRST STEP TO FULL DC-POTENTIAL: IMPROVING ENERGY EFFICIENCY IN HOUSEHOLD EQUIPMENT
    van Willigenburg, Pepijn
    Woudstra, Johan
    de Lange, Tim
    Stokman, Harry
    2014 PROCEEDINGS OF THE TWENTY SECOND CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2014,
  • [4] SHOCK ENERGY AND MYOCARDIAL DAMAGE AFTER SHOCKS FROM DC DEFIBRILLATORS IN DOGS
    ALLEN, JD
    PANTRIDGE, JF
    PATTON, JN
    JOURNAL OF PHYSIOLOGY-LONDON, 1978, 285 (DEC): : P14 - P15
  • [5] Energy Efficiency Evaluation and Revenue Distribution of DC Power Distribution Systems in Nearly Zero Energy Buildings
    Jiang, Keteng
    Li, Haibo
    Ye, Xi
    Lei, Yi
    Lao, Keng-Weng
    Zhang, Shuqing
    Hu, Xianfa
    ENERGIES, 2022, 15 (15)
  • [6] EVALUATION OF DEFIBRILLATORS
    不详
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1983, 7 (01) : 16 - 20
  • [7] UK First in Energy Efficiency
    不详
    ASHRAE JOURNAL, 2012, 54 (08) : 6 - 6
  • [8] EVALUATION OF DEFIBRILLATORS
    CRAIG, DM
    MACKINNON, DJ
    SHAW, A
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1985, 9 (01) : 33 - 33
  • [9] PROPOSALS FOR SELECTION AND TESTING OF DC DEFIBRILLATORS
    FINLAY, JB
    BIOMEDICAL ENGINEERING, 1974, 9 (11) : 517 - 521
  • [10] Research on Energy Efficiency of DC Distribution System
    Liu, Zifa
    Li, Mengyu
    2ND AASRI CONFERENCE ON POWER AND ENERGY SYSTEMS (PES2013), 2014, 7 : 68 - 74