Retrofitting of reinforced concrete columns under eccentric loads using enhanced ferrocement

被引:0
|
作者
Hesham Salim Al-Rawe [1 ]
Sofyan Y. Ahmed [1 ]
Salwa Mubarak Abdullah [1 ]
机构
[1] University of Mosul,Department of Civil Engineering, College of Engineering
关键词
Reinforced concrete columns; Retrofitting; Ferrocement jacketing; Biaxial; Preload;
D O I
10.1007/s42107-024-01141-6
中图分类号
学科分类号
摘要
Reinforced concrete columns are the most important load-bearing structural components in the buildings. These columns require retrofitting due to multiple reasons like poor design, inadequate materials, weak construction and improper quality control. This research involves retrofitting of reinforced concrete columns subjected to biaxial loads by using of enhanced ferrocement jacketing. Fifteen reinforced concrete columns are cast in 150 × 150 × 1700 mm including 250 × 250 × 250 mm concrete brackets at each end. They divided into three groups each with four columns in addition to the three control specimens. The three groups are preloaded up to 65 and 85% of the total failure loads of control specimens. After that, the first group retrofitted using traditional ferrocement consists of normal cement-sand mortar and reinforced with steel wire mesh. The second group retrofitted with modified mortar and steel wire mesh reinforcement. While the third group of columns retrofitted with modified mortar and reinforced with fiber glass mesh. All the columns are then biaxially loaded till failure with two different eccentricity values 30 and 70 mm. The results show that using enhanced ferrocement jacketing increases the load carrying capacity of retrofitted columns comparing to the control specimens with different percent of enhancement up to 30.6% for the column retrofitted with modified mortar and fiber glass mesh. Also, it develops the failure behavior, ductility ratio and cracks resistance of the retrofitted columns.
引用
收藏
页码:5727 / 5739
页数:12
相关论文
共 50 条
  • [1] Structural Performance of Eccentric Ferrocement Reinforced Concrete Columns
    Erfan, Abeer M.
    Ahmed, Hossam H.
    Mina, Bishoy A.
    El-Sayed, Taha A.
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2019, 11 (09) : 1213 - 1225
  • [2] Performance of Corroded Reinforced Concrete Columns under the Action of Eccentric Loads
    Xia, Jin
    Jin, Wei-Liang
    Li, Long-Yuan
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2016, 28 (01)
  • [3] Behaviour of reinforced concrete columns wrapped with fibre reinforced polymer under eccentric loads
    Hadi, M.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2009, 10 (02) : 169 - 178
  • [4] FIBER REINFORCED-CONCRETE SHORT COLUMNS UNDER UNIAXIALLY ECCENTRIC LOADS
    RAVINDRARAJAH, R
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1982, 73 (SEP): : 695 - 696
  • [5] Behavior of reinforced concrete columns with double spirals under axial and eccentric loads
    Zhou, Chunheng
    Chen, Zongping
    Huang, Zhenhua
    Cai, Liping
    JOURNAL OF BUILDING ENGINEERING, 2022, 51
  • [6] FIBER REINFORCED-CONCRETE SHORT COLUMNS UNDER UNIAXIALLY ECCENTRIC LOADS
    NIYOGI, SK
    CHAWLA, AP
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1982, 73 (MAR): : 199 - 206
  • [7] THE RETROFITTING OF REINFORCED CONCRETE COLUMNS
    Baciu, Catalin
    Murzea, Paricia
    Cucu, Vlad
    21ST INTERNATIONAL CONFERENCE THE KNOWLEDGE-BASED ORGANIZATION, 2015, 21 : 776 - 781
  • [8] Shear strengthening of reinforced concrete columns using ferrocement jacket
    Takiguchi, K
    Abdullah
    ACI STRUCTURAL JOURNAL, 2001, 98 (05) : 696 - 704
  • [9] Repairing reinforced concrete rectangular columns using ferrocement laminates
    Mourad, S. M.
    Shannag, M. J.
    CONCRETE SOLUTIONS, 2012, : 757 - 763
  • [10] BEHAVIOR OF BAMBOO-REINFORCED CONCRETE COLUMNS SUBJECTED TO ECCENTRIC LOADS
    COOK, DJ
    PAMA, RP
    SINGH, RV
    MAGAZINE OF CONCRETE RESEARCH, 1978, 30 (104) : 145 - 151