Correlation between right atrial pressure measured via right heart catheterization and venous excess ultrasound, inferior vena cava diameter, and ultrasound-measured jugular venous pressure: a prospective observational study

被引:1
|
作者
Klangthamneam, Suppawee [1 ]
Meemook, Krissada [1 ]
Petnak, Tananchai [1 ]
Sonkaew, Anchana [1 ]
Assavapokee, Taweevat [1 ]
机构
[1] Mahidol Univ, Ramathibodi Hosp, Fac Med, 270 Rama VI Rd, Bangkok 10400, Thailand
来源
ULTRASOUND JOURNAL | 2024年 / 16卷 / 01期
关键词
IVC; RAP; RHC; uJVP; VExUS; RETURN;
D O I
10.1186/s13089-024-00397-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Venous congestion is associated with adverse cardiovascular outcomes, necessitating accurate venous pressure assessment. Current methods, such as right heart catheterization (RHC), have limitations. Non-invasive techniques, including venous excess ultrasound (VExUS), inferior vena cava (IVC) assessment, and ultrasound-measured jugular venous pressure (uJVP), show promise but require validation in diverse populations. Aims We aimed to assess the correlation between right atrial pressure (RAP) via RHC and non-invasive methods, including VExUS, IVC diameter with collapsibility index (CI) by American Society of Echocardiography (ASE) classification, and uJVP. Methods In a prospective study involving 73 patients undergoing RHC, we evaluated the correlation between RAP and VExUS, IVC CI by ASE classification, and uJVP. We introduced and compared a modified VExUS grading system. Results VExUS significantly correlated with RAP (p < 0.001), especially between VExUS grade 0 and grade 3. RAP significantly differed across IVC classifications by ASE (P < 0.001). VExUS grade 0 correlated with IVC class 1, and VExUS grade 3 correlated with IVC class 3. The modified VExUS grading system improved low and high RAP differentiation. uJVP exhibited a robust, highly significant positive correlation with invasively measured RAP (rho = 0.67, P < 0.001). Conclusion This study establishes a strong correlation between non-invasive ultrasound measurements (VExUS, IVC diameter with CI, and uJVP) and invasively measured RAP. These findings underscore the clinical potential of these non-invasive techniques in venous congestion assessment and patient risk stratification.
引用
收藏
页数:11
相关论文
共 41 条
  • [1] Correlation between ultrasound-measured inferior vena cava diameter and peripherally inserted central catheter measured central venous pressure in low birth weight infants
    Li, Guang-Hong
    Du, Xiao-Qun
    Sun, Dong-Sheng
    Huang, Hui-Yi
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2025, 17 (03): : 2266 - 2275
  • [2] The Correlation Between Inferior Vena Cava Diameter Measured by Ultrasonography and Central Venous Pressure
    Vaish, Hans
    Kumar, Virendra
    Anand, Rama
    Chhapola, Viswas
    Kanwal, Sandeep Kumar
    INDIAN JOURNAL OF PEDIATRICS, 2017, 84 (10): : 757 - 762
  • [3] The Correlation Between Inferior Vena Cava Diameter Measured by Ultrasonography and Central Venous Pressure
    Hans Vaish
    Virendra Kumar
    Rama Anand
    Viswas Chhapola
    Sandeep Kumar Kanwal
    The Indian Journal of Pediatrics, 2017, 84 : 757 - 762
  • [4] Ultrasound Jugular Venous Pressure Collapse Point Predicts Elevated Right Atrial Pressure on Right Heart Catheterization in Obese and Nonobese Patients
    Wang, Libo
    Harrison, Jonathan
    Dranow, Elizabeth
    Khor, Lillian
    CIRCULATION, 2020, 142
  • [5] Clinical Utility Of Measured Jugular Venous Pressure To Predict Right Atrial Pressure
    Solverson, K. J.
    Vis, D.
    Braganza, M.
    Shaw, J.
    Weatherald, J.
    Thakrar, M.
    Varughese, R.
    Hirani, N.
    Helmersen, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [6] Ultrasound measured collapsibility of inferior vena cava comparison with central venous pressure in critically ill patients
    Kadhim, Maytham M.
    Ibrahim, Abdul Sattar Hadi
    Saad, Muthana Abdul Kadhim
    MEDICAL SCIENCE, 2021, 25 (113) : 1774 - 1779
  • [7] The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value
    Citilcioglu, Serenat
    Sebe, Ahmet
    Ay, Mehmet Oguzhan
    Icme, Ferhat
    Avci, Akkan
    Gulen, Muge
    Sahan, Mustafa
    Satar, Salim
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (02) : 310 - 315
  • [8] The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value
    Agmy, Gamal
    Wafy, Safaa
    Adam, Mohamed
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2020, 69 (02): : 415 - 420
  • [9] Estimation of Right Atrial Pressure on Inferior Vena Cava Ultrasound in Asian Patients
    Lee, Seitetsu L.
    Daimon, Masao
    Kawata, Takayuki
    Kohro, Takahide
    Kimura, Koichi
    Nakao, Tomoko
    Koide, Daisuke
    Watanabe, Masafumi
    Yamazaki, Tsutomu
    Komuro, Issei
    CIRCULATION JOURNAL, 2014, 78 (04) : 962 - 966
  • [10] Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated
    Bendjelid, K
    Romand, JA
    Walder, B
    Suter, PM
    Fournier, G
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (09) : 944 - 949