Development of respiratory motion-resolved hepatobiliary phase cine-magnetic resonance imaging for stereotactic body radiotherapy in liver tumor

被引:0
|
作者
Shimada, Ryuji [1 ,2 ]
Sofue, Keitaro [1 ]
Wang, Tianyuan [3 ]
Ishihara, Takeaki [3 ]
Ueshima, Eisuke [1 ]
Ueno, Yoshiko [1 ]
Kusaka, Akiko [2 ]
Murakami, Takamichi [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Radiol, Kobe, Japan
[2] Kobe Univ Hosp, Ctr Radiol & Radiat Oncol, Kobe, Japan
[3] Kobe Univ, Grad Sch Med, Dept Radiat Oncol, Kobe, Japan
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
EOB-DTPA; HEPATOCELLULAR-CARCINOMA; HEPATOCYTE-PHASE; ENHANCEMENT; MRI; INTENSITY; IMAGES;
D O I
10.1038/s41598-024-82860-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS. Phantom was imaged using cine-MRI and signal intensity (SI) and contrast ratio (CR) measured to determine the optimal flip-angle turbo field echo (TFE) prepulse delay. We performed cine-MRI in 20 patients for one minute, with images taken every 0.5 s after administration of gadoxetic acid contrast agent. Acquired images had three different acceleration factors (SENSE, CS without denoising [CS-no], and CS with strong denoising [CS-strong]). The image quality of the HBP cine MRI was quantitatively and qualitatively analyzed. In the phantom study, a flip angle of 30 degrees and TFE prepulse delay of 150 ms were optimal for clinical imaging. In a clinical study, CS-strong showed the highest signal-to-noise ratio and comparable contrast ratio among the three sequences. The CS-strong group showed a significantly higher image quality (P < 0.01), except for motion smoothness (P = 0.11). CS with denoising improved the tumor-to-liver contrast and image quality in high-temporal-resolution HBP cine MRI.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging
    Lever, Frederiek M.
    Lips, Irene M.
    Crijns, Sjoerd P. M.
    Reerink, Onne
    van Lier, Astrid L. H. M. W.
    Moerland, Marinus A.
    van Vulpen, Marco
    Meijer, Gert J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (02): : 419 - 424
  • [2] COMPARISON OF LIVER TUMOR MOTION WITH AND WITHOUT ABDOMINAL COMPRESSION USING CINE-MAGNETIC RESONANCE IMAGING
    Eccles, Cynthia L.
    Patel, Ritesh
    Simeonov, Anna K.
    Lockwood, Gina
    Haider, Masoom
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (02): : 602 - 608
  • [3] ASSESSMENT OF BLADDER MOTION FOR CLINICAL RADIOTHERAPY PRACTICE USING CINE-MAGNETIC RESONANCE IMAGING
    McBain, Catherine A.
    Khoo, Vincent S.
    Buckley, David L.
    Sykes, Jonathan S.
    Green, Melanie M.
    Cowan, Richard A.
    Hutchinson, Charles E.
    Moore, Christopher J.
    Price, Patricia M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : 664 - 671
  • [4] Three-dimensional motion of liver tumors using cine-magnetic resonance imaging
    Kirilova, Anna
    Lockwood, Gina
    Math, M.
    Choi, Perry
    Bana, Neelufer
    Haider, Masoom A.
    Brock, Kristy K.
    Eccles, Cynthia
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (04): : 1189 - 1195
  • [5] Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)
    Ghilezan, MJ
    Jaffray, DA
    Siewerdsen, JH
    van Herk, M
    Shetty, A
    Sharpe, MB
    Jafri, SZ
    Vicini, FA
    Matter, RC
    Brabbins, DS
    Martinez, AA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02): : 406 - 417
  • [6] Audiovisual Biofeedback Improves Cine-Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency
    Lee, Danny
    Greer, Peter B.
    Ludbrook, Joanna
    Arm, Jameen
    Hunter, Perry
    Pollock, Sean
    Makhija, Kuldeep
    O'brien, Ricky T.
    Kim, Taeho
    Keall, Paul
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (03): : 628 - 636
  • [7] Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
    Anthony G. Christodoulou
    Jaime L. Shaw
    Christopher Nguyen
    Qi Yang
    Yibin Xie
    Nan Wang
    Debiao Li
    Nature Biomedical Engineering, 2018, 2 : 215 - 226
  • [8] Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
    Christodoulou, Anthony G.
    Shaw, Jaime L.
    Nguyen, Christopher
    Yang, Qi
    Xie, Yibin
    Wang, Nan
    Li, Debiao
    NATURE BIOMEDICAL ENGINEERING, 2018, 2 (04): : 215 - 226
  • [9] Respiratory-induced Prostate Motion in the Supine and Prone Positions as Assessed by Cine-magnetic Resonance Imaging
    Nakamura, K.
    Anai, S.
    Hirakawa, M.
    Miyasaka, M.
    Yoshikawa, H.
    Sasaki, T.
    Shioyama, Y.
    Ohga, S.
    Terashima, K.
    Honda, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S386 - S386
  • [10] Comparative Assessment of Liver Tumor Motion Using Cine-Magnetic Resonance Imaging Versus 4-Dimensional Computed Tomography
    Fernandes, Annemarie T.
    Apisarnthanarax, Smith
    Yin, Lingshu
    Zou, Wei
    Rosen, Mark
    Plastaras, John P.
    Ben-Josef, Edgar
    Metz, James M.
    Teo, Boon-Keng