Verification of the multichannel pulsed ultrasonic Doppler velocimeter for the measurement of liquid metal flow

被引:0
|
作者
Ding-Yi Pan [1 ]
Yi-Fei Huang [1 ]
Ze Lyu [1 ]
Juan-Cheng Yang [2 ]
Ming-Jiu Ni [1 ]
机构
[1] University of Chinese Academy of Sciences,School of Engineering Science
[2] Xi’an Jiaotong University,State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace
关键词
D O I
10.1007/s00348-025-03985-3
中图分类号
学科分类号
摘要
In the present study, by adopting the advantage of ultrasonic techniques, we developed a multichannel pulsed ultrasonic Doppler velocimetry (MPUDV) to measure the two-dimension-two-component (2D-2C) velocity fields of liquid metal flow. Due to the specially designed ultrasonic host and post-processing scheme, the MPUDV system can reach a high spatiotemporal resolution of 50 Hz and 3 mm in the measurement zone of 192×192\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$192 \times 192$$\end{document}mm2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\text {mm}^{2}$$\end{document}. The experimental loop includes a cavity test section designed to establish a recirculating flow, thereby validating the accuracy of the MPUDV in measuring the velocity field with the well-developed particle image velocimetry (PIV). A comparison of the data obtained from the PIV and MPUDV methods revealed less than 3% differences exist in the 2D-2C velocity field between the two techniques during simultaneous measurements of the same flow field. This finding strongly demonstrates the reliability of the MPUDV method developed in this paper. Moreover, the ternary alloy GaInSn, which has a melting point below that of room temperature, was selected as the working liquid in the experimental loop to validate the efficacy of the MPUDV in measuring 2D-2C velocity fields. A series of tests were conducted in the cavity test section at varying Reynolds (Re) numbers, ranging from 9103 to 24,123. The measurements demonstrated that the MPUDV could accurately measure the flow structures, characterized by a central primary circulation eddy and two secondary eddies in the opaque liquid metal. Furthermore, comprehensive analyses of the velocity data obtained by the MPUDV were conducted. It was found that the vortex center of the primary circulating eddy and the size of the secondary eddies undergo significant alterations with varying Re numbers, attributed to the influence of the enhanced inertial forces on the flow within the cavity. It is therefore demonstrated that the current MPUDV methodology is applicable for measuring a 2D-2C velocity field in opaque liquid metal flows.
引用
收藏
相关论文
共 50 条
  • [1] LIQUID-METAL FLOW MEASUREMENTS USING AN ULTRASONIC DOPPLER VELOCIMETER
    FOWLIS, WW
    NATURE-PHYSICAL SCIENCE, 1973, 242 (114): : 12 - 13
  • [2] Measurement accuracy of the flow velocity in pulsed ultrasound Doppler velocimeter
    Kagiyama, M
    Ogasawara, Y
    Tadaoka, S
    Kajiya, F
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (08): : 1265 - 1274
  • [3] LIMITATIONS OF A PULSED DOPPLER-VELOCIMETER FOR BLOOD-FLOW MEASUREMENT IN SMALL VESSELS
    QUAIL, AW
    COTTEE, DBF
    WHITE, SW
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (06) : 2745 - 2754
  • [4] The use of an ultrasonic Doppler velocimeter in turbulent pipe flow
    G. Alfonsi
    S. Brambilla
    D. Chiuch
    Experiments in Fluids, 2003, 35 : 553 - 559
  • [5] The use of an ultrasonic Doppler velocimeter in turbulent pipe flow
    Alfonsi, G
    Brambilla, S
    Chiuch, D
    EXPERIMENTS IN FLUIDS, 2003, 35 (06) : 553 - 559
  • [6] TRANSCUTANEOUS FLOW MEASUREMENT BY DOPPLER ULTRASONIC VELOCIMETRY WITH PULSED EMISSIONS
    PERONNEAU, P
    XHAARD, M
    DIEBOLD, B
    FIESSINGER, JN
    LEVY, B
    NOUVELLE PRESSE MEDICALE, 1976, 5 (38): : 2547 - 2547
  • [7] AN IMPLANTABLE MULTICHANNEL ULTRASONIC PULSED DOPPLER BLOOD FLOWMETER
    YEUNG, KWW
    SEBEK, JJ
    MEINDL, JD
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 73 - 74
  • [8] REPEATABILITY OF BLOOD-FLOW MEASUREMENT USING MULTICHANNEL PULSED DOPPLER ULTRASOUND
    STACEYCLEAR, A
    FISH, PJ
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (677): : 419 - 420
  • [9] MEASUREMENT OF BLOOD-FLOW WITH ULTRASONIC PULSED DOPPLER-EFFECT
    GREENE, ER
    REVISTA MEDICA DE CHILE, 1983, 111 (05) : 495 - 504
  • [10] INTEGRATED ULTRASONIC PULSED DOPPLER SYSTEM FOR MEASUREMENT OF BLOOD-FLOW
    ROONEY, JA
    HEYSER, RC
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1985, 56 (05): : 493 - 493