Modeling and Analysis of Blood-Based Hybrid Nanofluid Flow Containing Ag and TiO2 Nanoparticles for Biomedical Applications: A Non-Fourier Approach

被引:0
|
作者
Al-Bossly, Afrah [1 ]
机构
[1] Prince Sattam bin Abdulaziz Univ, Coll Sci & Humanities Al Kharj, Dept Math, Al Kharj 11942, Saudi Arabia
关键词
Hybrid nanofluid; Blood circulation; Non-Fourier heat flux; Heat transport; Section/injection; Rectangular cross-section channel; Bvp4c technique;
D O I
10.1007/s12668-025-01865-y
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The key objective of the existing problem is to discuss the medical applications of the blood-based hybrid nanofluid model through the artery past a porous channel. Silver and titanium dioxide nanopartilces are utilized for the formation of the hybrid nanofluid. The medical uses of the current work are antibiotic coating on medical devices, creams, wound dressing, drug delivery, cancer, lung tumors, breathing, etc. Non-Fourier theory is employed in the proposed flow model in order to stabilize the heat transport. The predominant phenomena are modeled using nonlinear systems of partial differential equations. Through the use of similarity variables, the modeled PDEs are converted into highly nonlinear ODEs, and the suggested model's numerical solution is then obtained using the bvp4c approach. Relevant parameters of the flow model are deliberated graphically for the velocity profile, energy field, and for normal pressure drop field. For the validation perspective, the homotopy perturbation method (HPM) is adopted and implemented on the flow model. The range of embed factors are chosen as - 5.0 <= Re <= 5.0, - 1.0 <= alpha <= 1.0, - 0.2 <= S <= 0.2, phi 1 = 0.04, and phi 2 = 0.04. Some key results from the present study are that the velocity profile is enhanced for the porosity parameter, and the temperature field is dropped due to porosity in the presence of wall deformation. The porosity parameter has decayed the hybrid nanofluid temperature profile in case of suction. But in the case of injection, increase in porosity parameter led to amplified the hybrid nanofluid temperature. The convergence criteria of flow problem through bvp4c technique are successfully proved. A close agreement is found in bvp4c and HPM.
引用
收藏
页数:15
相关论文
共 19 条
  • [1] A comparative analysis of the blood-based hybrid nanofluid flow containing Cu and CuO nanoparticles over an exponentially extending surface
    Algehyne, Ebrahem A.
    Alamrani, Fahad Maqbul
    Khan, Arshad
    Khan, Khurshid Alam
    Lone, Showkat Ahmad
    Saeed, Anwar
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,
  • [2] Biomedical aspects of entropy generation on MHD flow of TiO2-Ag/blood hybrid nanofluid in a porous cylinder
    Shanmugapriyan, N.
    Jakeer, Shaik
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (11) : 1492 - 1509
  • [3] Effects of different nanoparticles Cu, TiO2, and Ag on fluid flow and heat transfer over cylindrical surface subject to non-fourier heat flux model
    Kumar, Pardeep
    Poonia, Hemant
    Ali, Liaqat
    Areekara, Sujesh
    Mathew, Alphonsa
    NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2024, 85 (03) : 325 - 343
  • [4] A theoretical study on (TiO2+Ag)/EO hybrid Casson nanofluid with motile micro-organisms in non-Fourier heat flux model
    Bibi, Taqmeem
    Sagheer, Muhammad
    Shahzad, Hassan
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2025, 8 (04)
  • [5] Non-similar bioconvective analysis of magnetized hybrid nanofluid (Ag plus TiO2) flow over exponential stretching surface
    Cui, Jifeng
    Haseena
    Farooq, Umer
    Jan, Ahmed
    Hussain, Muzamil
    HELIYON, 2024, 10 (09)
  • [6] TiO2-Ag/blood hybrid nanofluid flow through an artery with applications of drug delivery and blood circulation in the respiratory system
    Shojaie Chahregh, Hamidreza
    Dinarvand, Saeed
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2020, 30 (11) : 4775 - 4796
  • [7] Two-phase analysis on radiative solar pump applications using MHD Eyring–Powell hybrid nanofluid flow with the non-Fourier heat flux model
    Seethi Reddy Reddisekhar Reddy
    Shaik Jakeer
    Maduru Lakshmi Rupa
    Kuppala R. Sekhar
    Journal of Engineering Mathematics, 2024, 144
  • [8] Novel non-cytotoxic, bioactive and biodegradable hybrid materials based on polyurethanes/TiO2 for biomedical applications
    Gonzalez-Garcia, Dulce M.
    Tellez Jurado, L.
    Jimenez-Gallegos, R.
    Rodriguez-Lorenzo, Luis M.
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 375 - 384
  • [9] Entropy and Non-Fourier Flux on Hydro-magnetic Flow Among Nonlinearly Radiated Porous Micro Walls Filled with Blood-Based Different Shaped Ternary Nanoparticles
    Sajjan K.
    Vishnuvardhana S.V.
    Mamatha S.U.
    Raju C.S.K.
    International Journal of Applied and Computational Mathematics, 2024, 10 (3)
  • [10] Study of (Ag and TiO2)/water nanoparticles shape effect on heat transfer and hybrid nanofluid flow toward stretching shrinking horizontal cylinder
    Rashid, Umair
    Liang, Haiyi
    Ahmad, Hijaz
    Abbas, Muhammad
    Iqbal, Azhar
    Hamed, Y. S.
    RESULTS IN PHYSICS, 2021, 21