Efficacy and safety of selective laser trabeculoplasty for uveitic glaucoma

被引:0
|
作者
Suzuki, Minako [1 ]
Takeuchi, Masaki [1 ]
Meguro, Akira [1 ]
Nakamura, Jutaro [1 ]
Tateishi, Mamoru [1 ]
Fukuda, Miki [1 ]
Kamata, Akihiro [1 ]
Mizuki, Yuki [1 ]
Yamada, Kayoko [1 ]
Shibuya, Etsuko [1 ]
Yamada, Norihiro [1 ]
Ishihara, Mami [1 ]
Mizuki, Nobuhisa [1 ]
机构
[1] Yokohama City Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, 3-9 Fukuura,Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
INTRAOCULAR-PRESSURE ELEVATION; OPEN-ANGLE GLAUCOMA; SLT; STANDARDIZATION;
D O I
10.1038/s41598-025-88354-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To determine the efficacy and safety of selective laser trabeculoplasty (SLT) in patients with uveitic glaucoma, we retrospectively evaluated 17 eyes from 13 consecutive uveitic glaucoma cases who were treated with SLT due to inadequate interocular pressure (IOP) control despite glaucoma medical therapy. The mean IOP was significantly decreased from 28.4 +/- 6.50 mmHg to 17.3 +/- 9.4 mmHg at baseline, and 6 months after SLT, respectively (P < 0.0001). There was no significant increase in inflammation or prednisolone dosage following SLT. We compared the success group, which demonstrated successful IOP reduction after 6 months of SLT, to the other failure group. The success group had shorter uveitis duration (1.37 +/- 0.41 vs. 1.97 +/- 0.80 years, P = 0.032) and lower baseline IOP (25.5 +/- 5.09 vs. 33.7 +/- 5.57 mmHg, P = 0.035). This study found that SLT had a positive IOP-lowering effect and was safe in patients with uveitic glaucoma who had not responded to medical treatment.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Safety and Efficacy of Selective Laser Trabeculoplasty in Uveitic Glaucoma
    Patel, Pranav
    Foster, C. Stephen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [2] Selective laser trabeculoplasty in steroid-induced and uveitic glaucoma
    Zhou, Yujia
    Pruet, Christopher M.
    Fang, Chengbo
    Khanna, Cheryl L.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2022, 57 (04): : 277 - 283
  • [3] Efficacy and Safety of Selective Laser Trabeculoplasty among Ethiopian Glaucoma Patients
    Soboka, Jibat Gemida
    Giorgis, Abeba T.
    Alemu, Abiye M.
    Hodge, W. G.
    Damji, Karim F.
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [4] The Efficacy and Safety 180° Selective Laser Trabeculoplasty in Patients With Juvenile Glaucoma
    Park, J. K.
    Seo, H. -R.
    Jung, W. -J.
    Ahn, H. -B.
    Park, W. -C.
    Rho, S. H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Safety and efficacy of selective laser trabeculoplasty
    Hammer, A
    Wadhwa, SD
    Salvo, E
    Higginbotham, EJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Laser focus: Evaluating the safety and efficacy of selective laser trabeculoplasty in a variety of glaucoma patients
    Lewis, James S.
    Sahoo, Baswati
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 913 - 913
  • [7] The efficacy of selective laser trabeculoplasty versus argon laser trabeculoplasty in pseudophakic glaucoma patients
    Rosenfeld, Eldar
    Shemesh, Gabi
    Kurtz, Shimon
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 1935 - 1940
  • [8] Efficacy of selective laser trabeculoplasty following incisional glaucoma surgery
    Robert Allan Sharpe
    Leah L Kammerdiener
    David B.Williams
    Sudeep K.Das
    Matthew J.Nutaitis
    International Journal of Ophthalmology, 2018, 11 (01) : 71 - 76
  • [9] Efficacy of Selective Laser Trabeculoplasty on IOP reduction in glaucoma patients
    Kupin, TH
    Maldonado, RS
    Burks, R
    Gailitis, RP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Comparison of the efficacy and safety of selective laser trabeculoplasty in cases with primary open-angle glaucoma and pseudoexfoliative glaucoma
    Kara, Necip
    Altan, Cigdem
    Yuksel, Kemal
    Tetikoglu, Mehmet
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2013, 29 (09): : 500 - 504