Performance of electrochemical aptasensor as antigen test in clinical samples for early diagnosis of leptospirosis

被引:0
|
作者
Kositanont, Uraiwan [1 ]
Lertanantawong, Benchaporn [2 ]
Patarakul, Kanitha [3 ,4 ]
Sripinitchai, Sirinapa [5 ]
Thawornkuno, Charin [6 ]
Chaibun, Thanyarat [2 ]
Kreangkaiwal, Chahya [3 ]
Waiwinya, Wassa [7 ]
Promptmas, Chamras [2 ]
Srisawat, Chatchawan [5 ]
机构
[1] Thammasat Univ, Fac Publ Hlth, Pathum Thani, Thailand
[2] Mahidol Univ, Fac Engn, Dept Biomed Engn, Bangkok, Thailand
[3] Chulalongkorn Univ, Fac Med, Dept Microbiol, Bangkok, Thailand
[4] Chulalongkorn Univ, Chula Vaccine Res Ctr Chula VRC, Ctr Excellence Vaccine Res & Dev, Bangkok, Thailand
[5] Mahidol Univ, Fac Med, Siriraj Hosp, Dept Biochem, Bangkok, Thailand
[6] Mahidol Univ, Fac Trop Med, Dept Mol Trop Med & Genet, Bangkok, Thailand
[7] Chulalongkorn Univ, Grad Sch, Interdisciplinary Program, Med Microbiol, Bangkok, Thailand
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Early diagnosis; Leptospirosis; Antigen test; Diagnostic performance; Aptamer biosensor; Aptasensor; APTAMERS; SPP; EPIDEMIOLOGY; ANTIBODY; DEATH; PCR;
D O I
10.1038/s41598-025-92685-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Early diagnosis of leptospirosis is critical for timely treatment and effective disease management. This study evaluated the diagnostic performance of a novel electrochemical aptasensor targeting the electron transfer flavoprotein subunit beta (EtfB) of Leptospira interrogans in clinical samples collected during the acute phase of leptospirosis. The aptasensor assay was tested using plasma samples and compared to the microscopic agglutination test (MAT), the standard reference method. To assess diagnostic performance, aptasensor results were evaluated against leptospirosis status as determined by MAT. Receiver operating characteristic (ROC) analysis identified a 40% decrease in electrochemical signal relative to the blank as the optimal cut-off, yielding an area under the curve (AUC) of 0.93. The assay demonstrated a sensitivity of 100% and a specificity of 80%. For diagnostic concordance, aptasensor results were compared with those obtained from the reference quantitative PCR (qPCR) method. The aptasensor exhibited 100% positive agreement and 57.1% negative agreement with qPCR. Notably, in patients with high MAT titers, the aptasensor outperformed qPCR in detection rates (100% vs. 25%). These findings indicate that the aptasensor assay is a highly reliable and effective antigen-based diagnostic tool for early leptospirosis detection, making it suitable for both low- and high-prevalence settings.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Electrochemical aptasensor detection of electron transfer flavoprotein subunit beta for leptospirosis diagnosis
    Kositanont, Uraiwan
    Srisawat, Chatchawan
    Sripinitchai, Sirinapa
    Thawornkuno, Charin
    Chaibun, Thanyarat
    Karunaithas, Sinthu
    Promptmas, Chamras
    Lertanantawong, Benchaporn
    ANALYST, 2023, 148 (19) : 4777 - 4786
  • [2] PROGNOSTIC VALUE OF EARLY CLINICAL DIAGNOSIS OF LEPTOSPIROSIS
    Gancheva, Galya
    JOURNAL OF IMAB, 2022, 28 (03): : 4450 - 4455
  • [3] Leptospirosis: possibilities of early laboratory and clinical diagnosis
    Cermakova, Zuzana
    Kucerova, Petra
    Valenta, Zbynek
    Pliskova, Lenka
    Bolehovska, Radka
    Prasil, Petr
    Buchta, Vladimir
    Scharfen, Josef
    Polak, Pavel
    Pavlis, Ota
    Voxova, Barbora
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2013, 8 (01): : 84 - 89
  • [4] IMMUNOPEROXIDASE STAINING OF CLINICAL SPECIMENS FOR THE EARLY DIAGNOSIS OF LEPTOSPIROSIS
    LIGTHART, GS
    EVERARD, COR
    TERPSTRA, WJ
    TROPICAL AND GEOGRAPHICAL MEDICINE, 1987, 39 (01): : S14 - S14
  • [5] Electrochemical Aptasensor of Cardiac Troponin I for the Early Diagnosis of Acute Myocardial Infarction
    Jo, Hunho
    Gu, Hyunwoo
    Jeon, Weejeong
    Youn, Hyungjun
    Her, Jin
    Kim, Seong-Kyeong
    Lee, Jeongbong
    Shin, Jae Ho
    Ban, Changill
    ANALYTICAL CHEMISTRY, 2015, 87 (19) : 9869 - 9875
  • [6] Evaluation of High Performance Liquid Chromatography Purified Leptospiral Antigen for the Diagnosis of Leptospirosis
    Pol, Sae
    Bharadwaj, Renu
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2009, 62 (06) : 428 - 431
  • [7] Au Nanoparticle-Based Disposable Electrochemical Sensor for Detection of Leptospirosis in Clinical Samples
    Sapna, Kannan
    Sonia, Joseph
    Bo Shim, Yoon-
    Arun, A. B.
    Prasad, K. Sudhakara
    ACS APPLIED NANO MATERIALS, 2022, 5 (09) : 12454 - 12463
  • [8] An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples
    Ozyurt, Canan
    Uludag, Inci
    Sezginturk, Mustafa Kemal
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (06) : 1123 - 1136
  • [9] An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples
    Canan Özyurt
    İnci Uludağ
    Mustafa Kemal Sezgintürk
    Analytical and Bioanalytical Chemistry, 2023, 415 : 1123 - 1136
  • [10] A highly sensitive electrochemical aptasensor for detecting broad-spectrum estrogen molecules in clinical samples
    Liu, Siyao
    Yin, Ning
    Zhao, Ya
    Yan, Biao
    Li, Shengjie
    Gao, Shunxiang
    TALANTA, 2025, 283