Screening for Atrial Fibrillation During Routine Automated Blood Pressure Measurement in General Population Aged 65 Years and Above: EMENO National Epidemiological Survey in Greece

被引:0
|
作者
Menti, Ariadni [1 ]
Kalpourtzi, Natasa [2 ]
Kyriakoulis, Konstantinos G. [1 ]
Kollias, Anastasios [1 ]
Touloumi, Giota [2 ]
Stergiou, George S. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Med, Hypertens Ctr STRIDE 7, Dept Med 3,Sotiria Hosp, Athens, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Med, Dept Hyg Epidemiol & Med Stat, Athens, Greece
关键词
Anticoagulant drug treatment; Atrial fibrillation; Blood pressure monitor; Epidemiology; Prevalence; Screening; EUROPEAN-SOCIETY; PREVALENCE; HOME; COLLABORATION; HYPERTENSION; GUIDELINES; PREDICTORS; MANAGEMENT; OFFICE; STROKE;
D O I
10.1007/s40292-024-00672-y
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Introduction Atrial fibrillation (AF) is common with advanced aging and is often asymptomatic and undiagnosed. Aim A blood pressure (BP) monitor with embedded algorithm for detecting AF with high diagnostic accuracy during routine automated BP measurement was used to screen individuals aged >= 65 years. Methods The EMENO health survey (2013-2016) applied a multi-stage stratified random sampling method to select a random general adult population sample in Greece. Participants aged >= 65 years were screened for AF using an automated oscillometric device with AF detecting algorithm (Microlife BPA100 Plus AFIB) with triplicate measurements on a single occasion. ResultsA total of 975 individuals with AF data on at least one BP measurement were analysed [(mean (SD) age 73.2 (6.6) years, men 45%, hypertensives 79.3%). AF was detected in all 3 BP readings in 65 individuals (6.3%, AF group), in none of 3 readings in 661 (73.6%, non-AF group), and in 1-2 readings of 3 or less readings in 249 (20.1%, uncertain AF group). AF group individuals were older (p < 0.001), had lower systolic BP (p < 0.05) and more frequent cardiovascular disease (p < 0.01) compared to the non-AF and uncertain AF group. Moreover, 44.6% were unaware of their AF and all required anticoagulant therapy (CHA(2)DS(2)-VASc >= 1/>= 2, men/women). Conclusions About 6% of individuals aged >= 65 years in Greece appeared to have AF, and 44.6% of them were unaware and requiring anticoagulant treatment. AF screening during routine automated BP measurement appears to be a useful tool for early detection of asymptomatic AF in individuals aged >= 65 years.
引用
收藏
页码:649 / 655
页数:7
相关论文
共 7 条
  • [1] SCREENING FOR ATRIAL FIBRILLATION WITH ROUTINE AUTOMATED BLOOD PRESSURE MEASUREMENT IN THE ELDERLY: THE NATIONAL HEALTH SURVEY EMENO IN GREECE
    Stergiou, George S.
    Menti, Ariadni
    Kalpourtzi, Natasa
    Gavana, Magda
    Vantarakis, Apostolos
    Chlouverakis, Gregory
    Hadjichristodoulou, Christos
    Trypsianis, Gregory
    Voulgari, Paraskevi
    Alamanos, Yannis
    Karakosta, Argiro
    Touloumi, Giota
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E14 - E15
  • [2] General population screening for atrial fibrillation with an automated rhythm-detection blood pressure device
    Denas, Gentian
    Battaggia, Alessandro
    Fusello, Massimo
    Franco-Novelletto, Bruno
    Cancian, Maurizio
    Scalisi, Andrea
    Pengo, Vittorio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 322 : 265 - 270
  • [3] AUTOMATED DETECTION OF ATRIAL FIBRILLATION DURING ROUTINE OSCILLOMETRIC MEASUREMENT OF BLOOD PRESSURE: SYSTEMATIC REVIEW AND META-ANALYSIS
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    Chardouvelis, Panagiotis
    Ntousopoulos, Vasileios
    Menti, Ariadni
    Destounis, Antonios
    Stergiou, George S.
    JOURNAL OF HYPERTENSION, 2023, 41 : E20 - E20
  • [4] Screening for atrial fibrillation during automated blood pressure measurement among patients admitted to internal medicine ward
    Pucci, Giacomo
    Santoni, Edoardo
    Bisogni, Valeria
    Calandri, Camilla
    Cerasari, Alberto
    Dominioni, Irene
    Sanesi, Leandro
    D'Abbondanza, Marco
    Veca, Vito
    Vaudo, Gaetano
    INTERNAL AND EMERGENCY MEDICINE, 2021, 16 (06) : 1605 - 1611
  • [5] Screening for atrial fibrillation during automated blood pressure measurement among patients admitted to internal medicine ward
    Giacomo Pucci
    Edoardo Santoni
    Valeria Bisogni
    Camilla Calandri
    Alberto Cerasari
    Irene Dominioni
    Leandro Sanesi
    Marco D’Abbondanza
    Vito Veca
    Gaetano Vaudo
    Internal and Emergency Medicine, 2021, 16 : 1605 - 1611
  • [6] Atrial Fibrillation Screening During Routine Automated Office, Home, and Ambulatory Blood Pressure Measurement: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    Menti, Ariadni
    Chardouvelis, Panagiotis
    Stergiou, George S.
    HYPERTENSION, 2024, 81 (07) : 1477 - 1488
  • [7] AUTOMATED ATRIAL FIBRILLATION DETECTION DURING ROUTINE BLOOD PRESSURE MEASUREMENT: DIAGNOSTIC ACCURACY OF THE OSCILLOMETRIC BLOOD PRESSURE MONITOR MICROLIFE BP B3 AFIB ADVANCED
    Ntousopoulos, Vasileios
    Menti, Ariadni
    Kyriakoulis, Konstantinos
    Tsiachris, Dimitrios
    Kollias, Anastasios
    Stergiou, George
    JOURNAL OF HYPERTENSION, 2024, 42