Utilizing retinal arteriole/venule ratio to estimate intracranial pressure

被引:1
|
作者
Nortvig, Mathias Just [1 ,2 ,3 ]
Andersen, Mikkel Christian Schou [1 ,2 ,3 ]
Eriksen, Niclas Lynge [1 ,2 ,3 ]
Aunan-Diop, Jan Saip [1 ,2 ,3 ]
Pedersen, Christian Bonde [1 ,2 ,3 ]
Poulsen, Frantz Rom [1 ,2 ,3 ]
机构
[1] Odense Univ Hosp, Dept Neurosurg, DK-5000 Odense, Denmark
[2] Univ Southern, Clin Inst, Odense, Southern Denmar, Denmark
[3] Univ Southern, BRIDGE Brain Res Inter Disciplinary Guided Excelle, Odense, Southern Denmar, Denmark
关键词
Intracranial Pressure (ICP); Fundoscopy; Retinal arteriole/venule ratio; Non-invasive monitoring; Trauma; HYPERTENSION;
D O I
10.1007/s00701-024-06343-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Intracranial pressure (ICP) control is important to avoid secondary brain injury in patients with intracranial pathologies. Current methods for measuring ICP are invasive and carry risks of infection and hemorrhage. Previously we found correlation between ICP and the arteriole-venous ratio (A/V ratio) of retinal vessels in an outpatient setting. This study investigated the usability of fundoscopy for non-invasive ICP estimation with the addition of intraocular pressure (IOP) in patients in a neuro-intensive care unit (NICU). Methods This single-center prospective cohort study was conducted at the NICU of Odense University Hospital from September 2020 to May 2021. Adult patients with a Glasgow Coma Score of 8 or less, who underwent invasive pressure neuromonitoring were included. Fundoscopy videos were captured daily and analyzed using deep learning algorithms. The A/V ratio was calculated and correlated with ICP. The data was analyzed using mixed-effect linear regression models. Results Forty patients were enrolled. Fifteen were included in the final analysis. ICP ranged from -1 to 31 mmHg (mean: 10.9, SD: 5.7), and IOP ranged from 4 to 13 mmHg (mean: 7.4, SD: 2.1). The A/V ratio showed a significant negative correlation with ICP > 15 mmHg (regression slope: -0.0659, 95%-CI: [-0.0665;-0.0653], p < 0.001). No significant change in A/V ratio was observed for ICP <= 15 mmHg. A similar significant correlation was found for ICP > IOP (regression slope: -0.0055, 95%-CI: [-0.0062;-0.0048], p < 0.001). Taking the IOP into account did not improve the model. The sensitivity analysis showed a sensitivity of 80.08% and a specificity of 22.51%, with an AUC of 0.6389. Conclusion In line with our previous work, non-invasive fundoscopy is a potential tool for detecting elevated ICP. However, challenges such as image quality and diagnostic specificity remains. Further research with larger, multi-center studies are needed to validate the utility. Standardization may enhance the technique's clinical applicability.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The retinal arteriole to venule ratio: informative or deceptive?
    Ning Cheung
    Tien Y. Wong
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1245 - 1246
  • [2] The retinal arteriole to venule ratio: informative or deceptive?
    Cheung, Ning
    Wong, Tien Y.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (08) : 1245 - 1246
  • [3] Measurement of retinal vascular caliber: Issues and alternatives to using the arteriole to venule ratio
    Liew, Gerald
    Sharrett, A. Richey
    Kronmal, Richard
    Klein, Ronald
    Wong, Tien Yin
    Mitchell, Paul
    Kifley, Annette
    Wang, Jie Jin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 52 - 57
  • [4] Retinal arteriole-to-venule ratio in intracerebral haemorrhage subtypes and lacunar infarction
    Soderholm, M.
    Petersson, J.
    Zia, E.
    CEREBROVASCULAR DISEASES, 2013, 35 : 599 - 599
  • [5] Wall-to-Lumen Ratio of Retinal Arterioles and Arteriole-to-Venule Ratio of Retinal Vessels in Patients with Cerebrovascular Damage
    Baleanu, Delia
    Ritt, Martin
    Harazny, Joanna
    Heckmann, Josef
    Schmieder, Roland E.
    Michelson, Georg
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (09) : 4351 - 4359
  • [6] Improved Arteriole-to-Venule Ratio of Retinal Vessels Resulting From Bariatric Surgery
    Lammert, Alexander
    Hasenberg, Till
    Kraeupner, Caroline
    Schnuelle, Peter
    Hammes, Hans-Peter
    OBESITY, 2012, 20 (11) : 2262 - 2267
  • [7] Wall to lumen ratio of retinal arterioles versus arteriole to venule ratio of retinal vessels - Which parameter is the better indicator of cerebrovascular damage?
    Ritt, M.
    Harazny, J.
    Baleanu, D.
    Heckmann, J.
    Michelson, G.
    Schmieder, R.
    JOURNAL OF HYPERTENSION, 2008, 26 : S400 - S400
  • [8] Automated Arteriole and Venule Recognition in Retinal Images using Ensemble Classification
    Fraz, M. M.
    Rudnicka, A. R.
    Owen, C. G.
    Strachan, D. P.
    Barman, S. A.
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION, THEORY AND APPLICATIONS (VISAPP 2014), VOL 3, 2014, : 194 - 202
  • [9] Reply to “The retinal arteriole to venule ratio: informative or deceptive?” by N. Cheung and T. Y. Wong
    Virpi Hemminki
    Mika Kähönen
    Martti T. Tuomisto
    Hannu Uusitalo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 1247 - 1248
  • [10] Reply to "The retinal arteriole to venule ratio:: informative or deceptive?": by N.!Cheung and T. Y.!Wong
    Hemminki, Virpi
    Kahonen, Mika
    Tuomisto, Martti T.
    Uusitalo, Hannu
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (08) : 1247 - 1248