Morphological and Mechanical Property Differences in Trapeziometacarpal Ligaments of Healthy and Osteoarthritic Female Joints

被引:0
|
作者
Walker, Lizzie [1 ]
Gordon, Daniel [1 ]
Chiaramonti, Alexander [2 ]
Wang, Shangping [1 ,3 ]
Meng, Zhaoxu [4 ]
Daley, Dane [3 ]
Slate, Elizabeth [5 ]
Yao, Hai [1 ,3 ]
Pellegrini, Vincent D. [6 ]
Wu, Yongren [1 ,3 ]
机构
[1] Clemson Univ, Dept Bioengn, 68 President St,BEB 203, Charleston, SC 29425 USA
[2] Wake Forest Univ, Dept Orthopaed Surg & Rehabil, Sch Med, Winston Salem, NC USA
[3] Med Univ South Carolina, Dept Orthopaed & Phys Med, Charleston, SC 29425 USA
[4] Clemson Univ, Dept Mech Engn, Clemson, SC USA
[5] Florida State Univ, Dept Stat, Tallahassee, FL USA
[6] Dartmouth Hitchcock Med Ctr, Dept Orthopaed, Lebanon, NH USA
基金
美国国家卫生研究院;
关键词
Trapeziometacarpal osteoarthritis; Carpometacarpal osteoarthritis; Anterior oblique ligament; Trapeziometacarpal ligaments; Mechanical properties; Static stabilizer; ARTICULAR-CARTILAGE DEGENERATION; THUMB CARPOMETACARPAL JOINT; EATON CLASSIFICATION; ANTERIOR OBLIQUE; PATTERNS; ANATOMY; PATHOPHYSIOLOGY; RELIABILITY; WRIST;
D O I
10.1007/s10439-024-03660-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeTo identify changes in morphological and mechanical properties in the volar ligament complex (VLC), dorsoradial ligaments (DRL), and posterior oblique ligaments (POL) in healthy and osteoarthritic female trapeziometacarpal (TMC) joints.MethodsTwenty-four fresh-frozen female cadaveric TMCs were separated into (1) younger healthy/early-stage osteoarthritic, (2) elder healthy/early-stage osteoarthritic, and (3) advanced-stage osteoarthritic groups based on age and Eaton-Littler grading. Stress relaxation and load-to-failure testing were performed to characterize mechanical tensile properties. Light imaging and scanning electron microscopy (SEM)/energy dispersive spectroscopy (EDS) were performed to further assess enthesis structural integrity.ResultsThe VLC in advanced-stage osteoarthritic TMCs had attenuated mechanical properties in stress relaxation experiments compared to the elder healthy/early-stage osteoarthritic specimens: Young's modulus at 20% strain (P = 0.044), instantaneous (P = 0.023), relaxed (P = 0.017) moduli. VLCs in advanced-stage osteoarthritic TMCs also had significantly lower properties in the load-to-failure experiments compared to the younger healthy/early-stage osteoarthritic specimens: stiffness (P = 0.048), ultimate load (P = 0.017), toughness (P = 0.003). Light and SEM/EDS imaging revealed partial detachment and loss of enthesis mineral gradient at VLC metacarpal insertion in advanced-stage osteoarthritic specimens. There were no mechanical or structural changes in the DRL and POL between experiment groups.ConclusionVLC morphological and mechanical properties deteriorate across progressively severe osteoarthritis classifications while the DRL and POL remain unchanged. The attenuated mechanical properties of VLCs in advanced-stage osteoarthritic TMCs can be explained by ligament degradation as evidenced by partial detachment and loss of mineral gradient at the metacarpal insertion.
引用
收藏
页码:799 / 811
页数:13
相关论文
共 5 条
  • [1] Morphological and Mechanical Property Differences in Trapeziometacarpal Ligaments of Healthy and Osteoarthritic Female Joints (dec,10.1007/s10439-024-03660-4,2024)
    Walker, Lizzie
    Gordon, Daniel
    Chiaramonti, Alexander
    Wang, Shangping
    Meng, Zhaoxu
    Daley, Dane
    Slate, Elizabeth
    Yao, Hai
    Pellegrini, Vincent D.
    Wu, Yongren
    ANNALS OF BIOMEDICAL ENGINEERING, 2025, : 812 - 812
  • [2] A Regional Mapping of Articular Cartilage Integrity and Biphasic Properties in Healthy and Osteoarthritic Trapeziometacarpal Joints
    Walker, Lizzie
    Li, Hui
    Buchweitz, Nathan
    Gordon, Daniel
    Wang, Shangping
    Daley, Dane
    Yao, Hai
    Wu, Yongren
    ANNALS OF BIOMEDICAL ENGINEERING, 2025,
  • [4] Microstructure and mechanical property differences between friction stir lap welded joints using rotating and stationary shoulders
    Shude Ji
    Zhengwei Li
    Zhenlu Zhou
    Liguo Zhang
    The International Journal of Advanced Manufacturing Technology, 2017, 90 : 3045 - 3053
  • [5] Microstructure and mechanical property differences between friction stir lap welded joints using rotating and stationary shoulders
    Ji, Shude
    Li, Zhengwei
    Zhou, Zhenlu
    Zhang, Liguo
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2017, 90 (9-12): : 3045 - 3053