Discriminatory power of trabeculectomy bleb internal reflectivity and morphology in surgical success using anterior segment optical coherence tomography

被引:0
|
作者
Tan, Jeremy C. K. [1 ,2 ,3 ]
Roney, Matthew [1 ,4 ]
Posarelli, Matteo [1 ]
Ansari, Abdus Samad [3 ]
Batterbury, Mark [1 ]
Vallabh, Neeru A. [1 ,4 ]
机构
[1] Royal Liverpool Univ Hosp, St Pauls Eye Unit, Liverpool, England
[2] Univ New South Wales, Fac Med & Hlth, Kensington, NSW, Australia
[3] Moorfields Eye Hosp NHS Fdn Trust, Glaucoma Serv, London, England
[4] Univ Liverpool, Inst Life Course & Med Sci, Dept Eye & Vis Sci, Liverpool, England
关键词
Glaucoma surgery; Trabeculectomy; Mitomycin-C; Scleral flap; Sclerostomy; Surgical technique; Surgical success; FILTERING BLEBS; INTRAOCULAR-PRESSURE; DEEP SCLERECTOMY; GLAUCOMA;
D O I
10.1186/s12886-024-03770-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The post-operative evaluation of trabeculectomy blebs has traditionally relied on subjective clinical grading systems performed at the slit-lamp. This study explores the use of swept source anterior-segment optical coherence tomography (AS-OCT) to objectively measure bleb internal reflectivity and morphology, and to distinguish blebs with surgical success vs. failure. Methods Cross-sectional study of patients with glaucoma who had undergone trabeculectomy at least one year prior. Swept source AS-OCT was used to capture filtering blebs in the sagittal plane. Standardised regions of interests on the sagittal plane were segmented, and pixel intensity values and bleb height were measured. Receiver operating characteristic curves were used to examine the discriminatory ability of pixel intensity values and bleb morphology to classify blebs with surgical success or failure. Results 100 eyes of 65 patients were included, with a median post-operative follow up of 7.0 years (IQR 3.2-16 years). The proportion of complete success, qualified success and failure was 45%, 33%, and 22% respectively. The maximum bleb height was significantly greater in the blebs with complete success (1.74 vs. 1.25 vs. 1.23 mm in CS vs. QS vs. F, one-way ANOVA, p < 0.0001). Mean pixel intensity was significantly lower in blebs with complete success (150.8 vs. 157.4 vs. 167.4 in CS vs. QS vs. F, p = 0.0001). Bleb intensity standard deviation (AUC 0.81), maximal bleb height (AUC 0.76), mean pixel intensity (AUC 0.75) and minimum pixel intensity (AUC 0.75) offered the best discrimination between surgical success and failure. Conclusions Swept-source AS-OCT can be used to quantify bleb internal reflectivity and morphology, which can be used to distinguish between well vs. poorly functioning blebs. These parameters may assist surgeons in the objective evaluation of post-operative bleb outcomes.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Analysis of bleb morphology after trabeculectomy with Visante anterior segment optical coherence tomography
    Leung, Christopher Kai-shun
    Yick, Doris Wai-fong
    Kwong, Yolanda Yuen-ying
    Li, Felix Chi-hong
    Leung, Dexter Yu-lung
    Mohamed, Shaheeda
    Tham, Clement Chee-yung
    Chung-chai, Chi
    Lam, Dennis Shun-Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (03) : 340 - 344
  • [2] Early trabeculectomy bleb walls on anterior-segment optical coherence tomography
    Noriko Nakano
    Masanori Hangai
    Hideo Nakanishi
    Ryo Inoue
    Noriyuki Unoki
    Fumitaka Hirose
    Tomonari Ojima
    Nagahisa Yoshimura
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1173 - 1182
  • [3] Early trabeculectomy bleb walls on anterior-segment optical coherence tomography
    Nakano, Noriko
    Hangai, Masanori
    Nakanishi, Hideo
    Inoue, Ryo
    Unoki, Noriyuki
    Hirose, Fumitaka
    Ojima, Tomonari
    Yoshimura, Nagahisa
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (08) : 1173 - 1182
  • [4] Bleb Analysis by Using Anterior Segment Optical Coherence Tomography in Two Different Methods of Trabeculectomy
    Hamanaka, Teruhiko
    Omata, Takayasu
    Sekimoto, Shinichiro
    Sugiyama, Takakazu
    Fujikoshi, Yasunori
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 6536 - 6541
  • [5] Morphology of functioning trabeculectomy blebs using anterior segment optical coherence tomography
    Khamar, Mayuri B.
    Soni, Shruti R.
    Mehta, Siddharth V.
    Srivastava, Samaresh
    Vasavada, Viraj A.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (06) : 711 - 714
  • [6] Comparison of bleb morphology between trabeculectomy and deep sclerectomy using a clinical grading scale and anterior segment optical coherence tomography
    Oh, Lawrence J.
    Wong, Eugene
    Lam, Julie
    Clement, Colin I.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (07): : 701 - 707
  • [7] Bleb Grading Using Anterior Segment Optical Coherence Tomography
    Asrani, Sanjay
    Wen, Joanne C.
    JOURNAL OF GLAUCOMA, 2017, 26 (10) : E244 - E244
  • [8] Bleb analysis using anterior segment optical coherence tomography after trabeculectomy with amniotic membrane transplantation
    Kim, Hwayeong
    Moon, Sangwoo R.
    Kim, Eunah
    Kim, Jinmi
    Lee, Jiwoong
    PLOS ONE, 2023, 18 (05):
  • [9] Trabeculectomy bleb assessment via three-dimensional anterior segment optical coherence tomography
    Kawaji, Takahiro
    Inoue, Toshihiro
    Matsumura, Riyo
    Kuroda, Utako
    Kei-Ichi, Nakashima
    Tanihara, Hidenobu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Imaging of trabeculectomy blebs using anterior segment optical coherence tomography
    Singh, Mandeep
    Chew, Paul T. K.
    Friedman, David S.
    Nolan, Winifred P.
    See, Jovina L.
    Smith, Scott D.
    Zheng, Ce
    Foster, Paul J.
    Aung, Tin