Prediction of subsequent vertebral fracture after percutaneous vertebral augmentation using MRI-based vertebral bone quality and CT-based Hounsfield units: a retrospective cross-sectional study

被引:0
|
作者
Youdi Xue [1 ]
Kun Shi [1 ]
Weixiang Dai [1 ]
Chao Ma [1 ]
Jie Li [1 ]
机构
[1] Xuzhou Clinical School of Xuzhou Medical University,Department of Orthopaedics, Xuzhou Central Hospital
关键词
Oeteoporotic vertebral compressive fracture; Subsequent vertebral fracture; Hounsfield unit; Vertebral bone quality; Hyperlipidemia;
D O I
10.1038/s41598-025-86721-5
中图分类号
学科分类号
摘要
Subsequent vertebral fracture (SVF) is a common and refractory complication after percutaneous vertebral augmentation (PVA) for osteoporotic vertebral compression fracture (OVCF). Computed tomography (CT)-based Hounsfeld units (HU) and magnetic resonance imaging (MRI)-based vertebral bone quality (VBQ) score can evaluate osteoporosis quantitatively, hyperlipidemia(HLP) might affect measurement result of VBQ score. The primary objective of this study is to compare the predictive capabilities of HU and VBQ for SVF, and to clarify the impact of hyperlipidemia on the predictive abilities. This study included consecutive 341 patients with OVCF who were treated with PVA from March 1, 2020, to December 31, 2022. A multivariate logistic regression analysis was used to determine the relationship between HU and VBQ and SVF. ROC curves were plotted to calculate area under curve (AUC), and hoc analysis and Youden index was used to determine cut-off values of HU and VBQ. Compared with the non-SVF group, VBQ (4.69 ± 0.35 vs. 4.14 ± 0.41, P < 0.001) was higher and HU (58.2 ± 13.81 vs. 81.2 ± 16.68, P < 0.001) was lower in the SVF group. On multivariate logistic regression analysis, higher VBQ (odds ratio (OR) = 23.47,P < 0.001) and lower HU (OR = 0.93,P < 0.001) are independent predictors for SVF. The AUC using VBQ for predicting SVF was 0.84, the cut-off was 4.28. The AUC using HU for predicting SVF was 0.85, the cut-off was 64.40. In the HLP group, the AUC of VBQ was comparable with that of HU for SVF prediction, however, the sensitivity was lower in the HLP group (0.50 vs. 0.83). Furthermore, the AUC value of VBQ with HLP was lower than that of VBQ without HLP (0.78 vs. 0.90, P = 0.017). These findings demonstrated that both VBQ and HU can accurately predict the occurrence of SVF after PVA. HLP might cause a false increase of VBQ value, using HU could better assess bone quality and predict SVF occurrence when HLP is present.
引用
收藏
相关论文
共 29 条
  • [1] CT-based vertebral three-dimensional Hounsfield unit can predict the new vertebral fracture after percutaneous vertebral augmentation in postmenopausal women: a retrospective study
    Rongkun Chang
    Feng Chang
    Yang You
    Zhaowei Wang
    Zhen Geng
    Rongcan Liu
    Ruopeng Mai
    Yinbin Wang
    Lijun Cai
    Journal of Orthopaedic Surgery and Research, 20 (1)
  • [2] CT-based radiomics predicts adjacent vertebral fracture after percutaneous vertebral augmentation
    Jin Yang
    Shu-Bao Zhang
    Shuo Yang
    Xiao-Yong Ge
    Chang-Xu Ren
    Shan-Jin Wang
    European Spine Journal, 2025, 34 (2) : 528 - 536
  • [3] MRI-Based Vertebral Bone Quality Score Can Predict the Imminent New Vertebral Fracture After Vertebral Augmentation
    Cai, Jinhui
    Han, Wen
    Yang, Tingqian
    Ye, Haoyi
    Jiang, Yang
    Liu, Zhifeng
    Liu, Qingyu
    NEUROSURGERY, 2024, 95 (03) : 566 - 575
  • [4] The correlation between self-Hounsfield units and adjacent vertebral fracture after percutaneous vertebral augmentation: a retrospective cohort study
    Qi, Yugui
    Zhang, Zhaochuan
    Han, Meng
    Shi, Kun
    Ma, Chao
    Xue, Youdi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (03) : 2405 - 2414
  • [5] MRI-based radiomics assessment of the imminent new vertebral fracture after vertebral augmentation
    Cai, Jinhui
    Shen, Chen
    Yang, Tingqian
    Jiang, Yang
    Ye, Haoyi
    Ruan, Yaoqin
    Zhu, Xuemin
    Liu, Zhifeng
    Liu, Qingyu
    EUROPEAN SPINE JOURNAL, 2023, 32 (11) : 3892 - 3905
  • [6] MRI-based radiomics assessment of the imminent new vertebral fracture after vertebral augmentation
    Jinhui Cai
    Chen Shen
    Tingqian Yang
    Yang Jiang
    Haoyi Ye
    Yaoqin Ruan
    Xuemin Zhu
    Zhifeng Liu
    Qingyu Liu
    European Spine Journal, 2023, 32 : 3892 - 3905
  • [7] Utility of MRI-based vertebral bone quality scores and CT-based Hounsfield unit values in vertebral bone mineral density assessment for patients with diffuse idiopathic skeletal hyperostosis
    Chen, Haojie
    Zhu, Xiufen
    Zhou, Qingshuang
    Pu, Xiaojiang
    Wang, Bin
    Lin, Hua
    Zhu, Zezhang
    Qiu, Yong
    Sun, Xu
    OSTEOPOROSIS INTERNATIONAL, 2024, 35 (04) : 705 - 715
  • [8] Utility of MRI-based vertebral bone quality scores and CT-based Hounsfield unit values in vertebral bone mineral density assessment for patients with diffuse idiopathic skeletal hyperostosis
    Haojie Chen
    Xiufen Zhu
    Qingshuang Zhou
    Xiaojiang Pu
    Bin Wang
    Hua Lin
    Zezhang Zhu
    Yong Qiu
    Xu Sun
    Osteoporosis International, 2024, 35 : 705 - 715
  • [9] Comparison of predictive performance for cage subsidence between CT-based Hounsfield units and MRI-based vertebral bone quality score following oblique lumbar interbody fusion
    Xingxiao Pu
    Xiandi Wang
    Liyu Ran
    Tianhang Xie
    Zhuhai Li
    Zhiqiang Yang
    Run Lin
    Jiancheng Zeng
    European Radiology, 2023, 33 : 8637 - 8644
  • [10] Comparison of predictive performance for cage subsidence between CT-based Hounsfield units and MRI-based vertebral bone quality score following oblique lumbar interbody fusion
    Pu, Xingxiao
    Wang, Xiandi
    Ran, Liyu
    Xie, Tianhang
    Li, Zhuhai
    Yang, Zhiqiang
    Lin, Run
    Zeng, Jiancheng
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 8637 - 8644