Optimizing voltage references in a 3-leg power VSC under single-phase-to-ground faults

被引:0
|
作者
Davila, Asier [1 ]
Garcia, Unai [2 ]
Gonzalez, Uxue [2 ]
Rementeria, Jon Xabier [2 ]
Andres, Ainhize San [2 ]
Planas, Estefanía [2 ]
机构
[1] Department of Electronics Technology, Bilbao School of Engineering – University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo, Bilbao, Bilbao,48013, Spain
[2] Department of Electrical Engineering, Bilbao School of Engineering – University of the Basque Country (UPV/EHU), Plaza Ingeniero Torres Quevedo, Bilbao, Bilbao,48013, Spain
来源
关键词
Distribution grid deals with several challenges such as the integration of the electrical vehicle; connection of renewable energy resources; management of storage systems; etc. These new factors can often produce some non-desirable effects in the grid such as electrical faults; which can damage the electricity supply quality. In order to improve the supply quality during electrical faults; power converters with specific control algorithms can be connected that modify the voltage on the loads connected to the grid during the duration of the fault. An optimal control can be ensured if a proper estimation of the voltage in the load is carried on. This paper calculates the voltage drop between the output of the power converter and the fault point so as to optimize voltage references in the power converter during single-phase-to-ground faults in islanded mode. Simulation results guarantee the successful performance of the proposal. © 2024; European Association for the Development of Renewable Energy; Environment and Power Quality (EA4EPQ). All rights reserved;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:118 / 123
相关论文
共 50 条
  • [1] Analysis of overvoltages in overhead ground wires of extra high voltage (EHV) power transmission line under single-phase-to-ground faults
    Dudurych, I
    Rosolowski, E
    ELECTRIC POWER SYSTEMS RESEARCH, 2000, 53 (02) : 105 - 111
  • [2] Estimating Locations of Single-phase-to-ground Faults of Ungrounded Distribution Systems
    Sun, Hongbo
    Nikovski, Daniel
    Takano, Tomihiro
    Kojima, Yasuhiro
    Ohno, Tetsufumi
    2013 4TH IEEE/PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2013,
  • [3] Method for Locating of Single-phase-to-ground Faults in Ungrounded Distribution Systems
    Sun, Hongbo
    Nikovski, Daniel
    Takano, Tomihiro
    Kojima, Yasuhiro
    Ohno, Tetsufumi
    2013 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2013,
  • [4] Single-phase-to-ground fault in extra-high-voltage lines
    Fan, Yue
    Shi, Wei
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2000, 34 (04): : 18 - 22
  • [5] Overvoltages due to single-phase-to-ground and double-phase faults on a 20 kV feeder
    Waluyo
    Saodah, Siti
    Saranga, Febriany Kalatiku
    EEA - Electrotehnica, Electronica, Automatica, 2020, 68 (01): : 1 - 11
  • [6] Integration of New Single-Phase-to-Ground Faults Detection Devices into Existing SmartGrid Systems
    Viacheslav, Bezruchko
    Roman, Buinyi
    Andrij, Strogii
    Volodymyr, Tkach
    2019 IEEE 6TH INTERNATIONAL CONFERENCE ON ENERGY SMART SYSTEMS (2019 IEEE ESS), 2019, : 84 - 87
  • [7] Fault phase fast detection of the single-phase-to-ground fault in a power distribution network
    Ye Y.
    Cai X.
    Xie M.
    Xu B.
    Wei L.
    1600, Power System Protection and Control Press (49): : 96 - 103
  • [8] Analytical Calculation Models for Bipolar MMC-HVDC Systems Under Valve-Side Single-Phase-to-Ground Faults
    Sun, Pingyang
    Li, Gen
    Zhang, Hanwen
    Liang, Jun
    Konstantinou, Georgios
    IEEE TRANSACTIONS ON POWER DELIVERY, 2025, 40 (02) : 988 - 1001
  • [9] Discharge Ignition Mechanism of Tree-contacting Single-phase-to-ground Faults of Overhead Lines
    Qin J.
    Ning X.
    Fan S.
    Jia Z.
    Dianwang Jishu/Power System Technology, 2023, 47 (03): : 1289 - 1298
  • [10] Transient characteristics of single-phase-to-ground fault in the indirectly earthed power system
    Tang, Yi
    Chen, Kui
    Chen, Qing
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (11): : 175 - 179