Gold removal from e-waste using high-intensity focused ultrasound

被引:0
|
作者
Holmström, Axi [1 ]
Pudas, Topi [1 ]
Hyvönen, Jere [1 ]
Weber, Martin [1 ]
Mizohata, Kenichiro [2 ]
Sillanpää, Tom [1 ,3 ]
Mäkinen, Joni [1 ]
Kuronen, Antti [2 ]
Kotiaho, Tapio [3 ,4 ]
Hæggström, Edward [1 ]
Salmi, Ari [1 ]
机构
[1] Electronics Research Laboratory, Faculty of Science, University of Helsinki, P.O.B. 64, FIN-00014 University of Helsinki, Finland
[2] Accelerator Laboratory, Faculty of Science, University of Helsinki, P.O.B. 43, FIN-00014 University of Helsinki, Finland
[3] Drug Research Program and Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O.B. 56, FIN-00014 University of Helsinki, Finland
[4] Department of Chemistry, Faculty of Science, University of Helsinki, P.O.B 55, FIN-00014 University of Helsinki, Finland
关键词
Cavitation corrosion - Electronic Waste - Gold - Gold coatings - Gold metallography - Gold metallurgy - Hydrometallurgy - Pyrometallurgy - Ultrasonic transducers;
D O I
10.1016/j.ultsonch.2024.107109
中图分类号
学科分类号
摘要
The demand for rare and precious metals (RPMs), e.g. gold, is increasing, as these are used in the ever-increasing amount of electronics needed for technological development and digitalization. Due to their rarity, virgin mining of RPMs is becoming more difficult and expensive. At the same time, over 62 Mt of e-waste is created globally each year. The high concentration of gold and other RPMs in e-waste makes it an excellent source for recycling. Unfortunately, current recycling methods need to separate the different metals and the current pyrometallurgical and hydrometallurgical processes also create toxic pollutants, large amounts of wastewater and require highly corrosive substances. Here we present a new method for gold removal for the purpose of recycling, using only water and high-intensity focused ultrasound to induce material erosion through cavitation. An 11.8 MHz ultrasonic transducer is used to first image the sample to locate gold-coated pads on discarded printed circuit boards (PCBs) and subsequently to remove only the gold layer. We demonstrate that the gold removal can be controlled by the number of transmitted ultrasonic bursts and that the energy efficiency is optimal when only minute amounts of the nickel layer beneath are also removed. Removing solely the gold layer also decreases the need for further processing steps. This greener gold removal method for e-waste is therefore well aligned with, and contributing to, the United Nations Sustainable Development Goal 12: Ensure sustainable consumption and production patterns. © 2024 The Author(s)
引用
收藏
相关论文
共 50 条
  • [1] Liver hemostasis using high-intensity focused ultrasound
    Vaezy, S
    Martin, R
    Schmiedl, U
    Caps, M
    Taylor, S
    Beach, K
    Carter, S
    Kaczkowski, P
    Keilman, G
    Helton, S
    Chandler, W
    Mourad, P
    Rice, M
    Roy, R
    Crum, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (09): : 1413 - 1420
  • [2] Removal of Common Warts by High-Intensity Focused Ultrasound: An Introductory Observation
    Bove, Torsten
    Zawada, Tomasz
    Jessen, Alexander
    Poli, Mattia
    Serup, Jorgen
    CASE REPORTS IN DERMATOLOGY, 2021, 13 (02): : 340 - 346
  • [3] High-intensity focused ultrasound and cryotherapy
    Murat, F. J.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 78 : S11 - S11
  • [4] High-intensity focused ultrasound therapy
    Cheung, Vincent Y. T.
    BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2018, 46 : 74 - 83
  • [5] Myocardial lesion formation using high-intensity focused ultrasound
    Engel, David J.
    Muratore, Robert
    Hirata, Kumiko
    Otsuka, Ryo
    Fujikura, Kana
    Sugioka, Kenichi
    Marboe, Charles
    Lizzi, Frederic L.
    Homma, Shunichi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (07) : 932 - 937
  • [6] PRODUCTION OF CORNEAL LESIONS USING HIGH-INTENSITY FOCUSED ULTRASOUND
    RUTZEN, AR
    ROBERTS, CW
    DRILLER, J
    GOMEZ, D
    LUCAS, BC
    LIZZI, FL
    COLEMAN, DJ
    CORNEA, 1990, 9 (04) : 324 - 330
  • [7] High-intensity focused ultrasound beam path visualization using ultrasound imaging
    Song, Jae Hee
    Chang, Jin Ho
    Yoo, Yang Mo
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2020, 39 (01): : 16 - 23
  • [8] TREATMENT OF GLAUCOMA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    VALTOT, F
    KOPEL, J
    HAUT, J
    INTERNATIONAL OPHTHALMOLOGY, 1989, 13 (1-2) : 167 - 170
  • [9] An early history of high-intensity focused ultrasound
    O'Brien, William D., Jr.
    Dunn, Floyd
    PHYSICS TODAY, 2015, 68 (10) : 40 - 45
  • [10] A Review of High-Intensity Focused Ultrasound in Urology
    Cranston, David
    Leslie, Tom
    ter Haar, Gail
    CANCERS, 2021, 13 (22)