Constraint-Aware Learning for Fractional Flow Reserve Pullback Curve Estimation From Invasive Coronary Imaging

被引:1
|
作者
Zhang, Dong [1 ,2 ]
Liu, Xiujian [2 ]
Wang, Anbang [2 ]
Zhang, Hongwei [2 ]
Yang, Guang [3 ,4 ]
Zhang, Heye [2 ]
Gao, Zhifan [2 ]
机构
[1] Anhui Med Univ, Sch Biomed Engn, Hefei 230032, Peoples R China
[2] Sun Yat Sen Univ, Sch Biomed Engn, Shenzhen 510275, Peoples R China
[3] Royal Brompton Hosp, Cardiovasc Res Ctr, London SW3 6NP, England
[4] Imperial Coll London, Natl Heart & Lung Inst, London SW7 2AZ, England
基金
中国国家自然科学基金;
关键词
Synthetic data; Arteries; Imaging; Estimation; Mathematical models; Geometry; Adaptation models; Constraint-aware learning; coronary intervention; fractional flow reserve; synthetic data;
D O I
10.1109/TMI.2024.3412935
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Estimation of the fractional flow reserve (FFR) pullback curve from invasive coronary imaging is important for the intraoperative guidance of coronary intervention. Machine/deep learning has been proven effective in FFR pullback curve estimation. However, the existing methods suffer from inadequate incorporation of intrinsic geometry associations and physics knowledge. In this paper, we propose a constraint-aware learning framework to improve the estimation of the FFR pullback curve from invasive coronary imaging. It incorporates both geometrical and physical constraints to approximate the relationships between the geometric structure and FFR values along the coronary artery centerline. Our method also leverages the power of synthetic data in model training to reduce the collection costs of clinical data. Moreover, to bridge the domain gap between synthetic and real data distributions when testing on real-world imaging data, we also employ a diffusion-driven test-time data adaptation method that preserves the knowledge learned in synthetic data. Specifically, this method learns a diffusion model of the synthetic data distribution and then projects real data to the synthetic data distribution at test time. Extensive experimental studies on a synthetic dataset and a real-world dataset of 382 patients covering three imaging modalities have shown the better performance of our method for FFR estimation of stenotic coronary arteries, compared with other machine/deep learning-based FFR estimation models and computational fluid dynamics-based model. The results also provide high agreement and correlation between the FFR predictions of our method and the invasively measured FFR values. The plausibility of FFR predictions along the coronary artery centerline is also validated.
引用
收藏
页码:4091 / 4104
页数:14
相关论文
共 50 条
  • [1] Safe Learning by Constraint-Aware Policy Optimization for Robotic Ultrasound Imaging
    Duan, Anqing
    Yang, Chenguang
    Zhao, Jingyuan
    Huo, Shengzeng
    Zhou, Peng
    Ma, Wanyu
    Zheng, Yongping
    Navarro-Alarcon, David
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2025, 22 : 2349 - 2360
  • [2] Safe Learning by Constraint-Aware Policy Optimization for Robotic Ultrasound Imaging
    Duan, Anqing
    Yang, Chenguang
    Zhao, Jingyuan
    Huo, Shengzeng
    Zhou, Peng
    Ma, Wanyu
    Zheng, Yongping
    Navarro-Alarcon, David
    IEEE Transactions on Automation Science and Engineering, 2025, 22 : 2349 - 2360
  • [3] Safe Learning by Constraint-Aware Policy Optimization for Robotic Ultrasound Imaging
    Duan, Anqing
    Yang, Chenguang
    Zhao, Jingyuan
    Huo, Shengzeng
    Zhou, Peng
    Ma, Wanyu
    Zheng, Yongping
    Navarro-Alarcon, David
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2025, 22 : 2349 - 2360
  • [4] Accuracy and usefulness of noninvasive fractional flow reserve from computed tomographic coronary angiography: comparison with myocardial perfusion imaging, echocardiographic coronary flow reserve, and invasive fractional flow reserve
    Taguchi E.
    Nakao K.
    Hirakawa K.
    Fukunaga T.
    Miyamoto S.
    Sakamoto T.
    Cardiovascular Intervention and Therapeutics, 2017, 32 (1) : 66 - 71
  • [5] Visualization of the improvement of myocardial perfusion after coronary intervention using motorized fractional flow reserve pullback curve
    Matsuo A.
    Shimoo S.
    Takamatsu K.
    Tsuji Y.
    Kyodo A.
    Mera K.
    Koide M.
    Isodono K.
    Tsubakimoto Y.
    Sakatani T.
    Inoue K.
    Fujita H.
    Cardiovascular Intervention and Therapeutics, 2018, 33 (2) : 99 - 108
  • [6] Invasive imaging - Fractional flow reserve: a review
    De Bruyne, B.
    Sarma, J.
    HEART, 2008, 94 (07) : 949 - 959
  • [7] Virtual Fractional Flow Reserve Derived From Invasive Coronary Angiography
    Fan, Guoxin
    Qi, Xiaolong
    Yang, Changqing
    Fu, Qingsong
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (02) : E16 - E17
  • [8] Invasive functional evaluation of coronary stenoses by fractional reserve of coronary flow
    Di Serafino, Luigi
    Barbato, Emanuele
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (01) : 16 - 24
  • [9] Computing Fractional Flow Reserve From Invasive Coronary Angiography Getting Closer
    Morris, Paul D.
    Gunn, Julian P.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (09)
  • [10] Comparison of adenosine magnetic resonance perfusion imaging with invasive coronary flow reserve and fractional flow reserve in patients with suspected coronary artery disease
    Kirschbaum, Sharon W.
    Springeling, Tirza
    Rossi, Alexia
    Duckers, Eric
    Gutierrez-Chico, Juan Luis
    Regar, Eveline
    de Feyter, Pim J.
    van Geuns, Robert-Jan M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 (01) : 184 - 186