A Novel Hand-Held Multi-Color Magnetic Particle Imaging Device Based on Rapid Frequency Conversion

被引:0
|
作者
Zhang, Haoran [1 ,2 ,3 ,4 ]
Zhang, Bo [1 ,2 ,3 ,4 ]
Li, Jiaqian [1 ,2 ,3 ,4 ]
Zhou, Guangxing [1 ,2 ,3 ,4 ]
Lei, Siao [1 ,2 ,3 ,4 ]
An, Yu [1 ,2 ,3 ,4 ]
Tian, Jie [1 ,2 ,3 ,4 ]
机构
[1] Beihang Univ, Sch Engn Med, Beijing, Peoples R China
[2] Beihang Univ, Sch Biol Sci & Med Engn, Beijing, Peoples R China
[3] Beihang Univ, Key Lab Big Data Based Precis Med, Minist Ind & Informat Technol China, Beijing, Peoples R China
[4] Natl Key Lab Kidney Dis, Beijing, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金; 国家重点研发计划;
关键词
Coils; Frequency conversion; Spatial resolution; Harmonic analysis; Accuracy; Magnetic resonance imaging; Permanent magnets; Drive field; hand-held; magnetic particle imaging (MPI); multi-color MPI; rapid frequency conversion;
D O I
10.1109/TBME.2024.3434961
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Multi-color Magnetic Particle Imaging (MPI) technology offers high sensitivity and non-invasive imaging capabilities. It can simultaneously image multiple superparamagnetic iron oxide nanoparticles (SPIOs), facilitating more precise detection of multiple molecular markers in vivo. However, the fixed drive frequency of existing hand-held MPI devices makes it difficult to fully match the nonlinear magnetic response of different SPIOs, affecting the effect of multi-color imaging. Methods: We designed a novel hand-held rapid frequency conversion based multi-color MPI (RFC-MPI) device. This device adjusts the drive frequency based on magnetic response at different frequencies, effectively expanding the system matrix information and thereby improving spatial resolution and multi-color imaging capabilities simultaneously. Results: The device achieved a spatial resolution of 27 mm and an imaging speed of 1 frame/s. The scanning depth is 8 mm. It was used to scan a 22 cm x 22 cm area of a human-shaped phantom, verifying its potential for scanning humans. The ability of the device to quantify SPIOs was validated using mice breast tumors. The quantitative accuracy was determined to be 96.58%. Conclusion: Due to its innovative structural design and rapid frequency conversion method, the RFC-MPI device exhibits excellent in vivo imaging performance. Both simulation and phantom experiments have verified the effectiveness of the proposed method. Significance: The hand-held RFC-MPI device can effectively improve the spatial resolution and quantitative accuracy of multi-color MPI, laying the foundation for future clinical applications.
引用
收藏
页码:3602 / 3611
页数:10
相关论文
共 18 条
  • [1] Multi-color magnetic particle imaging for cardiovascular interventions
    Haegele, Julian
    Vaalma, Sarah
    Panagiotopoulos, Nikolaos
    Barkhausen, Joerg
    Vogt, Florian M.
    Borgert, Joern
    Rahmer, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (16): : N415 - N426
  • [2] INVESTIGATIONS ON THE ROBUSTNESS OF PARTICLE SEPARATION IN MULTI-COLOR MAGNETIC PARTICLE IMAGING
    Rahmer, J.
    Halkola, A.
    Gleich, B.
    Schmale, I.
    Borgert, J.
    2015 5TH INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2015, : O6 - O6
  • [3] Calibration-Free Relaxation-Based Multi-Color Magnetic Particle Imaging
    Muslu, Yavuz
    Utkur, Mustafa
    Demirel, Omer Burak
    Saritas, Emine Ulku
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (08) : 1920 - 1931
  • [4] First experimental evidence of the feasibility of multi-color magnetic particle imaging
    Rahmer, J.
    Halkola, A.
    Gleich, B.
    Schmale, I.
    Borgert, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 1775 - 1791
  • [5] Hand-held multi-wavelength spatial frequency domain imaging for breast cancer imaging
    Robbins, Constance M.
    Yang, Jason
    Antaki, James F.
    Kainerstorfer, Jana M.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XIII, 2019, 10874
  • [6] A multi spectral hand-held spatial frequency domain imaging system for imaging human colorectal cancer
    Zeng, Yifeng
    Li, Shuying
    Erfanzadeh, Mohsen
    Nandy, Sreyankar
    Chapman, William, Jr.
    Alipour, Zahra
    Abdelal, Heba
    Chatterjee, Deyali
    Mutch, Matthew
    Zhu, Quing
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XIII, 2019, 10874
  • [7] Image Infusion of Photoacoustic Imaging Based on Novel Adjustable Hand-held Probe
    Zhao, Yongjian
    Jiang, Daohuai
    Lan, Hengrong
    Gao, Fei
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 2366 - 2368
  • [8] Simplified size-based immune cell monitoring using a hand-held particle counting device
    Smith, Janet L.
    Cappione, Amedeo
    JOURNAL OF IMMUNOLOGY, 2020, 204 (01):
  • [9] Rapid and Automatic Classification of Tobacco Leaves Using a Hand-Held DLP-Based NIR Spectroscopy Device
    Zhang Jianqiang
    Yang Panpan
    Liu Weijuan
    Yang Yanmei
    Yuan Tianjun
    Hou Ying
    Li Changyu
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2019, 30 (09) : 1927 - 1932
  • [10] Rapid TAURUS for Relaxation-Based Color Magnetic Particle Imaging
    Arslan, M. Tunc
    Ozaslan, A. Alper
    Kurt, Semih
    Muslu, Yavuz
    Saritas, Emine Ulku
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (12) : 3774 - 3786