Design, fabrication and validation of a low-cost stereotaxic device for brain research in rodents

被引:0
|
作者
Wadkar, Avinash [1 ]
Patkar, Heramb [2 ]
Kommajosyula, Srinivasa Prasad [1 ]
机构
[1] Birla Inst Technol & Sci, Dept Pharm, Hyderabad Campus, Hyderabad 500078, India
[2] Birla Inst Technol & Sci, Dept Mech Engn, Hyderabad Campus, Hyderabad 500078, India
关键词
Stereotaxic device; brain research; rodents; computer numerical control; low-cost; SURGERY; ACCURACY;
D O I
10.1007/s12034-024-03377-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Environmental toxicants can impact brain health and function. Studying their effects on the rodent brain is paramount to understanding the mechanisms and devising therapies. The stereotaxic device is widely used to target brain regions. However, the cost of this device is very high and cannot be afforded by researchers from low- and low-middle-income countries. This study has modelled, designed, fabricated, and evaluated a cost-effective stereotaxic device. A 3-D model of the stereotaxic device was prepared using FUSION 360 software followed by fabrication using aluminium and steel. The aluminium has malleability, lightweight, high extrudability, and corrosion resistance property, making it the material of choice for fabricating the nose clamp, mouth restrainer, and ear bar. To construct the parts requiring motion, we used alloy steel, which has high density, tensile strength and smooth texture. To achieve better accuracy, computer numerical control (CNC) and an automatic wire-cutting (EDM) manufacturing processes were used in fabrication. Later, the dye microinjection and electrolytic lesion techniques were used to validate this instrument. A comparison of percent accuracy for hitting structures between the fabricated and commercial stereotaxic devices for both the deep and superficial brain structures such as the substantia nigra (91.7 vs. 92.5%), thalamus (92.6 vs. 98.22%) and hippocampus (92.85 vs. 98.75%), showcased comparable accuracies between devices. The cost of the materials used were approximately nine thousand Indian rupees, and the labour charges for different machining processes used were approximately seventeen thousand Indian rupees. Totalling to 26,000 Indian rupees or 310 US dollars. This cost may vary depending on the material type/vendor as well. The materials can be provided to a workshop, and the design reported here can be used to make a stereotaxic device for rodent research. The 3-D modeling approach presented here coupled with computerised numerical control/electronic discharge machining process achieves high precision comparable to a commercial product and is also affordable. This study will enable students/researchers in middle and low-income countries to perform neuroscience/toxicological studies on the brain using this self-made low-cost precision device.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A low-cost device for cryoanesthesia of neonatal rodents
    Jamieson, Bradley B.
    Cano-Ferrer, Xavier
    Konstantinou, George
    de Launoit, Elisa
    Renier, Nicolas
    Imbert, Albane
    Kohl, Johannes
    HARDWAREX, 2023, 14
  • [2] DESIGN AND VALIDATION OF A LOW-COST HEART HEALTH MONITORING DEVICE
    Ahmed, Nuzhat
    Kline, Lucas
    Zhu, Yong
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 3, 2019,
  • [3] Design of a low-cost pressure measurement device: validation and testing
    The Tran Hung
    Dinh Le Anh
    Dinh-Dung Nguyen
    INTERNATIONAL JOURNAL OF SUSTAINABLE AVIATION, 2022, 8 (04) : 336 - 352
  • [4] Design and Validation of a Low-Cost Portable Device to Quantify Postural Stability
    Zhu, Yong
    SENSORS, 2017, 17 (03)
  • [5] A versatile, low-cost adaptor for stereotaxic and electrophysiologic spinal preparations in juvenile and adult rodents
    Cunningham, MG
    Donalds, RA
    Scouten, CW
    Tresch, MC
    BRAIN RESEARCH BULLETIN, 2005, 68 (03) : 157 - 162
  • [6] A Low-Cost Super-Resolution Tactile Sensor: Design, Fabrication, and Validation
    Lu, Zhou
    Su, Yuan
    Ye, Qi
    Wang, Ze
    Shi, Xiufang
    Li, Gaofeng
    Chen, Jiming
    IEEE SENSORS JOURNAL, 2024, 24 (22) : 36518 - 36529
  • [7] Design and Validation of a Low-Cost Wearable Assistive Device for Carrying Back Loads
    Vishnu, Rajendran S.
    Rahul, K.
    Maurin, Aymeric
    Harish, Mohan T.
    Mohan, Renjith
    Bhavani, Rao R.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (11) : 24397 - 24403
  • [9] Design and Fabrication of Low-Cost PUMA Arrays
    Holland, Steven S.
    Vouvakis, Marinos N.
    2011 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (APSURSI), 2011, : 1976 - 1979
  • [10] DESIGN AND VALIDATION OF A LOW-COST TELEMICROSCOPY SYSTEM
    Prieto-Egido, Ignacio
    Garcia-Giganto, Victor
    Gonzalez-Escalada, Alba
    Martinez-Fernandez, Andres
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCES ON ICT, SOCIETY AND HUMAN BEINGS 2014, WEB BASED COMMUNITIES AND SOCIAL MEDIA 2014, E-COMMERCE 2014, INFORMATION SYSTEMS POST-IMPLEMENTATION AND CHANGE MANAGEMENT 2014 AND E-HEALTH 2014, 2014, : 279 - 286