PROPOSAL FOR A NON-CONTACT MICROTREMOR MEASUREMENT METHOD OF TRADITIONAL WOODEN BUILDINGS USING A LASER DOPPLER VELOCIMETER

被引:0
|
作者
Rongji F. [1 ,3 ]
Mina S. [1 ,3 ]
Ayumi Y. [2 ]
机构
[1] Dept. of Architecture and Architectural Engineer, Kyoto Univ.
[2] Dept. of Architecture, The Univ. of Tokyo
[3] Dept. of Architecture and Architectural Engineer, Kyoto Univ.
关键词
Laser Doppler Velocimeter; Microtremor measurements; Natural frequency; Traditional wooden building;
D O I
10.3130/aijt.30.716
中图分类号
学科分类号
摘要
When performing microtremor measurements on traditional wooden buildings, it can be difficult to install sensors. This study aims to propose a non-contact microtremor measurement method for tradition wooden buildings using a Laser Doppler Velocimeter (LDV). First, we summarized the LDV measurement system and waveform processing method. Next, we examined the non-contact microtremor measurement method to measure one building of Tofukuji Temple as an example. Then, accuracy of LDV measurement results was verified by comparing the LDV measurement results with the accelerometer results. Furthermore, examples of measurements made on other buildings in Tofukuji Temple were also presented. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:716 / 721
页数:5
相关论文
共 50 条
  • [1] Non-contact measurement of ocular microtremor using laser speckle
    Kenny, E.
    Coakley, D.
    Boyle, G.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE II, 2010, 7715
  • [2] Non-contact in vivo measurement of ocular microtremor using laser speckle correlation metrology
    Kenny, E.
    Coakley, D.
    Boyle, G.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (07) : 1229 - 1243
  • [3] NON-CONTACT METHOD FOR LENGTH MEASUREMENT USING DOPPLER EFFECT
    ZERVOS, P
    PTB-MITTEILUNGEN, 1978, 88 (03): : 193 - 197
  • [4] Non-contact measurement of facial actions using laser Doppler vibrometry
    Rohrbaugh, J. W.
    Sirevaag, E. J.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2012, 85 (03) : 312 - 312
  • [5] In-situ damage detection in plate structures using PWAS and non-contact laser Doppler velocimeter
    Kumar, P. Padma
    Sekhar, B. V. Soma
    Balasubramaniam, Krishnan
    Krishnamurthy, C. V.
    Maxfield, Bruce
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 26A AND 26B, 2007, 894 : 1509 - 1515
  • [6] Non-contact measurement of firmness properties of fruits and vegetables using a parabolic-reflector airborne ultrasonic transducer and laser Doppler velocimeter
    Tabaru, Marie
    Wu, Cyui
    Murata, Kento
    Aoyagi, Takahiro
    Nakamura, Kentaro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (08)
  • [7] Non-contact measurement of firmness properties of fruits and vegetables using a parabolic-reflector airborne ultrasonic transducer and laser Doppler velocimeter
    Tabaru, Marie
    Wu, Cyui
    Murata, Kento
    Aoyagi, Takahiro
    Nakamura, Kentaro
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2024, 63 (08):
  • [8] Measurement of flaps blood flow by using non-contact laser Doppler flowmeter
    Jinnouchi, S
    Goto, M
    Katsuki, T
    4TH MEDITERRANEAN CONGRESS OF ORAL AND MAXILLOFACIAL SURGERY, 1997, : 59 - 66
  • [9] Non-contact measurement of eyeblink by using Doppler sensor
    Maleki, Amir
    Uchida, Masafumi
    ARTIFICIAL LIFE AND ROBOTICS, 2018, 23 (02) : 279 - 285
  • [10] A Non-Contact Detection and Measurement Method of Conversation and Mastication using a Doppler sensor
    Yamada, Mikiya
    Kamiya, Yukihiro
    2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 250 - 251