Healing of Long Fatigue Cracks in Steel Plates by High-Density Current Pulses

被引:0
|
作者
Kukudzhanov, K. V. [1 ]
Khalikova, G. R. [2 ,3 ]
Korznikova, E. A. [2 ,4 ]
Chentsov, A. V. [1 ,5 ]
Dmitriev, S. V. [2 ,3 ,6 ]
机构
[1] Russian Acad Sci, Ishlinsky Inst Problems Mech, Moscow 119526, Russia
[2] Russian Acad Sci, Inst Met Superplast Problems, Ufa 450001, Russia
[3] Ufa State Petr Technol Univ, Ufa 450064, Russia
[4] Ufa Univ Sci & Technol, Ufa 450076, Russia
[5] Moscow State Univ Civil Engn, Moscow 129337, Russia
[6] Russian Acad Sci, UFRC, Inst Mol & Crystal Phys, Ufa 450054, Russia
关键词
crack healing; steel; high density electric pulse;
D O I
10.1134/S0025654424605949
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The healing of cracks in metals and alloys by means of exposure to strong pulsed electromagnetic fields is of considerable interest, since it allows to increase the reliability and service life of structural materials and products made of them. In spite of practical importance, the methodology of selection of the parameters of the electric pulse treatment, which would allow to heal the defects, has not been developed yet. Healing of long macrocracks in thin plates by welding of their edges under electric pulse action is of particular difficulty. The present work is devoted to the study of the possibility of selecting the parameters of electric pulse treatment for such a case. The mechanism of healing of macrocracks in flat specimens is considered. The proposed multistage method of electric pulse treatment allowed to heal a significant length of macrocrack in a steel plate. The conducted studies of microstructure of cross-sections of AISI201 stainless steel samples confirm that healing occurs by the mechanism of welding of crack edges by molten material. The electric pulse creates at the tip of the crack significant compressive stress and high temperature, causing the melting of steel. The experiments showed significant heterogeneity of healing along the macrocrack front and in depth, however, the quality of healing improved with increasing distance from the plate surface. In the healed region along the crack edges, a zone with elongated grains surrounding a central zone with equiaxed grains is observed, which reflects the kinetics of cooling of the molten region of the specimen exposed to the current pulse.
引用
收藏
页码:3223 / 3234
页数:12
相关论文
共 50 条
  • [1] Healing fatigue damage in steel with electric current pulses
    Zuev, LB
    Sosnin, OV
    Podboronnikov, SF
    Gromov, VE
    Gorlova, SN
    TECHNICAL PHYSICS, 2000, 45 (03) : 309 - 311
  • [2] Healing fatigue damage in steel with electric current pulses
    L. B. Zuev
    O. V. Sosnin
    S. F. Podboronnikov
    V. E. Gromov
    S. N. Gorlova
    Technical Physics, 2000, 45 : 309 - 311
  • [3] EFFECT OF HIGH DENSITY ELECTRIC CURRENT FIELD ON FATIGUE CRACKS IN STAINLESS STEEL
    Hosoi, A.
    Nagahama, T.
    Ju, Y.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE 2010), VOL 9, 2012, : 123 - 128
  • [4] Restoration of fatigue damage in stainless steel by high-density electric current
    Tang, Yongpeng
    Hosoi, Atsushi
    Morita, Yasuyuki
    Ju, Yang
    INTERNATIONAL JOURNAL OF FATIGUE, 2013, 56 : 69 - 74
  • [5] Mechanism of Fatigue Crack Closure in Steel Under High-Density Pulsed Current
    Nakayama, Shota
    Sugeno, Yutaro
    Kambayashi, Tomoto
    Hosoi, Atsushi
    Furukawa, Yuichi
    Tomita, Takashi
    Kawada, Hiroyuki
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2025, 48 (04) : 1879 - 1892
  • [6] Effect of High-Density Electric Current on the Microstructure and Fatigue Crack Initiation of Stainless Steel
    Tang, Yongpeng
    Hosoi, Atsushi
    Iwase, Yuichi
    Ju, Yang
    MATERIALS TRANSACTIONS, 2013, 54 (11) : 2085 - 2092
  • [7] FATIGUE TESTS ON NOTCHED MILD STEEL PLATES WITH MEASUREMENTS OF FATIGUE CRACKS
    FROST, NE
    DUGDALE, DS
    JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 1957, 5 (03) : 182 - 192
  • [8] New high-density plates
    Rogers, MV
    DRUG DISCOVERY TODAY, 1997, 2 (11) : 504 - 504
  • [9] Effect of high density pulse current on healing of cracks of SiCp/Al composites
    Yi Z.
    Lai X.
    Wang B.
    Zhang J.
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2017, 38 (11):
  • [10] INITIATION OF FATIGUE CRACKS FROM NOTCHES IN MILD STEEL PLATES
    JACK, AR
    PRICE, AT
    INTERNATIONAL JOURNAL OF FRACTURE MECHANICS, 1970, 6 (04): : 401 - 409