Multielement electrochemical vapor generation system coupled with atomic fluorescence spectrometer for simultaneous measurement of trace levels of As and Hg in coastal seawater samples

被引:0
|
作者
Chen, Luodan [1 ,3 ]
Wu, Rongkun [2 ]
Xu, Biqing [2 ]
Gong, Zhenbin [1 ,3 ]
Yuan, Dongxing [1 ]
机构
[1] Xiamen Univ, State Key Lab Marine Environm Sci, Xiamen 361102, Peoples R China
[2] Tairui Sci & Technol Co Ltd, Quanzhou 362000, Peoples R China
[3] Xiamen Univ, Coll Environm & Ecol, Ctr Marine Environm Chem & Toxicol, Xiamen 361102, Peoples R China
关键词
Ultra-trace As and Hg in seawater; Simultaneous determination; Electrochemical vapor generation; Multichannel atomic fluorescence spectrometer; MODIFIED GRAPHITE ELECTRODE; HYDRIDE GENERATION; MERCURY; ABSORPTION; SPECIATION; RESOLUTION; ELEMENTS; METALS; WATER; GOLD;
D O I
10.1016/j.aca.2024.343301
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Toxic elements As and Hg in coastal waters affect human health through the food chain even at trace levels. The simultaneous determination of As and Hg in seawater using electrochemical vapor generation (ECVG) with atomic fluorescence spectrometer (AFS) currently has technical bottlenecks. One is the need for a simple and efficient chemical reaction cell and corresponding parameters to generate both AsH3 3 and Hg vapors, and the other is a suitable preservation method of the mixed standard solutions. Results: A novel, efficient, online ECVG device was developed and interfaced with a laboratory-built multichannel AFS. The electrolytic cell adopted Sn-Pb alloy as the cathode material to generate both AsH3 3 and Hg vapors by electrolysis, replacing the unstable reagent tetrahydroborate (THB) usually used in most traditional vapor generation methods. The AFS was equipped with a built -in H2 2 generator for fuel supply, instead of the conventional acid-THB system. A mixed standard solution of As and Hg was prepared and preserved using thiourea-ascorbic acid as a fixing agent for Hg and a prereduction agent for As(V). The method detection limits (LOD, 3 sigma) were 0.005 and 0.003 mu g/L for As and Hg, respectively. The relative standard deviations (RSD, n = 8) of the spiked samples were 2.8 % (0.50 mu g/L As) and 3.1 % (0.05 mu g/L Hg), respectively. The recoveries of standard spiked seawater samples with different salinities ranged from 86.1 % to 115.3 %. Significance: The system has been successfully applied to the simultaneous analysis of As and Hg in the seawater samples collected from the Xiamen coastal area. The study results provide a sensitive, accurate, and efficient method to promote the development and utilization of simultaneous analysis of multielement in seawaters.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Simultaneous Measurement of Trace Levels of Hg, As, Sb, and Bi in Coastal Seawater with a Multichannel Chemical Vapor Generation Atomic Fluorescence Spectrometer
    Chen, Luodan
    Lin, Qinling
    Yuan, Dongxing
    Gong, Zhenbin
    ANALYTICAL CHEMISTRY, 2023, 95 (42) : 15621 - 15627
  • [2] Simultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry
    Gan, WE
    Shi, WW
    Su, QD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) : 911 - 916
  • [3] Ultra-trace determination of methylmercuy in seafood by atomic fluorescence spectrometry coupled with electrochemical cold vapor generation
    Zu, Wenchuan
    Wang, Zhenghao
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 304 : 467 - 473
  • [4] Electrolytic Cold Vapor Generation for Determination of Hg in Biologic Samples by Atomic Fluorescence Spectrometry
    Zhang Wang-Bing
    Chen Tong-Yun
    Su Zhao-Fei
    Gao Jia-You
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (06) : 935 - 938
  • [5] Chemical vapor generation coupled with atomic fluorescence spectrometry for the determination of manganese in food samples
    Zeng, Chujie
    Qin, Peipei
    Lan, Liling
    Wei, Haishi
    Wu, Wenfeng
    MICROCHEMICAL JOURNAL, 2017, 131 : 31 - 35
  • [6] Enhancement reagents for simultaneous vapor generation of zinc and cadmium with intermittent flow system coupled to atomic fluorescence spectrometry
    Sun, HW
    Suo, R
    ANALYTICA CHIMICA ACTA, 2004, 509 (01) : 71 - 76
  • [7] ZIRCONIUM COPRECIPITATION FOR SIMULTANEOUS MULTIELEMENT DETERMINATION OF TRACE-METALS IN SEAWATER BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    AKAGI, T
    NOJIRI, Y
    MATSUI, M
    HARAGUCHI, H
    APPLIED SPECTROSCOPY, 1985, 39 (04) : 662 - 667
  • [8] Continuous flow electrolytic cold vapor generation atomic fluorescence spectrometric determination of Hg in water samples
    Zhang, Wang-bing
    Yang, Xin-an
    Ma, Yuan-yuan
    Zhu, Hai-xia
    Wang, Shang-bing
    MICROCHEMICAL JOURNAL, 2011, 97 (02) : 201 - 206
  • [9] Comparison between Vapor Generation Methods Coupled to Atomic Absorption Spectrometry for Determination of Hg in Glycerin Samples
    Lisboa, Meibel Teixeira
    Clasen, Caroline Dutra
    Oreste, Eliezer Quadro
    Ribeiro, Anderson Schwingel
    Vieira, Mariana Antunes
    ENERGY & FUELS, 2015, 29 (03) : 1635 - 1640
  • [10] Simultaneous multielement determination of trace metals in seawater by inductively coupled plasma atomic emission spectrometry using chelating resin column preconcentration
    Chu, Jia Cheng
    Akagi, Tasuku
    Haraguchi, Hiroki
    Bulletin of the Chemical Society of Japan, 1985, 58 (11): : 3229 - 3234