A Wireless Multimodal Physiological Monitoring ASIC for Animal Health Monitoring Injectable Devices

被引:2
|
作者
Zhao, Linran [1 ]
Stephany, Raymond G. [1 ]
Han, Yiming [1 ]
Ahmmed, Parvez [2 ]
Huang, Tzu-Ping [1 ]
Bozkurt, Alper [2 ]
Jia, Yaoyao [1 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[2] North Carolina State Univ, Dept Elect & Comp Engn, Raleigh, NC 27697 USA
基金
美国国家科学基金会;
关键词
Animal health monitoring; injectable device; multimodal sensing; subcutaneous implant; electrocardiography; photoplethysmography; temperature measurement; WEARABLE DEVICES; AMPLIFIER; SYSTEM; SENSOR; RANGE;
D O I
10.1109/TBCAS.2024.3372571
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Utilizing injectable devices for monitoring animal health offers several advantages over traditional wearable devices, including improved signal-to-noise ratio (SNR) and enhanced immunity to motion artifacts. We present a wireless application-specific integrated circuit (ASIC) for injectable devices. The ASIC has multiple physiological sensing modalities including body temperature monitoring, electrocardiography (ECG), and photoplethysmography (PPG). The ASIC fabricated using the CMOS 180 nm process is sized to fit into an injectable microchip implant. The ASIC features a low-power design, drawing an average DC power of 155.3 mu W, enabling the ASIC to be wirelessly powered through an inductive link. To capture the ECG signal, we designed the ECG analog frontend (AFE) with 0.3 Hz low cut-off frequency and 45-79 dB adjustable midband gain. To measure PPG, we employ an energy-efficient and safe switched-capacitor-based (SC) light emitting diode (LED) driver to illuminate an LED with milliampere-level current pulses. A SC integrator-based AFE converts the current of photodiode with a programmable transimpedance gain. A resistor-based Wheatstone Bridge (WhB) temperature sensor followed by an instrumentation amplifier (IA) provides 27-47 degrees C sensing range with 0.02 degrees C inaccuracy. Recorded physiological signals are sequentially sampled and quantized by a 10-bit analog-to-digital converter (ADC) with the successive approximation register (SAR) architecture. The SAR ADC features an energy-efficient switching scheme and achieves a 57.5 dB signal-to-noise-and-distortion ratio (SNDR) within 1 kHz bandwidth. Then, a back data telemetry transmits the baseband data via a backscatter scheme with intermediate-frequency assistance. The ASIC's overall functionality and performance has been evaluated through an in vivo experiment.
引用
收藏
页码:1037 / 1049
页数:13
相关论文
共 50 条
  • [1] A Wireless Multimodal Physiological Monitoring ASIC for Injectable Implants
    Zhao, Linran
    Stephany, Raymond G.
    Han, Yiming
    Ahmmed, Parvez
    Bozkurt, Alper
    Jia, Yaoyao
    IEEE 49TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE, ESSCIRC 2023, 2023, : 305 - 308
  • [2] A Wireless Miniature Injectable Device With Memory-Assisted Backscatter for Multimodal Animal Physiological Monitoring
    Han, Yiming
    Stephany, Raymond G.
    Zhao, Linran
    Ahmmed, Parvez
    Bozkurt, Alper
    Jia, Yaoyao
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2025, 72 (03) : 988 - 999
  • [3] A Subcutaneously Injectable Implant for Multimodal Physiological Monitoring in Animals
    Ahmmed, Parvez
    Reynolds, James
    Bozkurt, Alper
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 11205 - 11216
  • [4] A Wireless Capsule System With ASIC for Monitoring the Physiological Signals of the Human Gastrointestinal Tract
    Xu, Fei
    Yan, Guozheng
    Zhao, Kai
    Lu, Li
    Gao, Jinyang
    Liu, Gang
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2014, 8 (06) : 871 - 880
  • [5] A Critical Review of Wireless Health Monitoring Devices
    Jena, Mihir Kumar
    Ansari, Irshad Ahmad
    2018 CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY (CICT'18), 2018,
  • [6] In Vivo Evaluation of a Subcutaneously Injectable Implant with a Low-Power Photoplethysmography ASIC for Animal Monitoring
    Valero-Sarmiento, Jose Manuel F.
    Ahmmed, Parvez
    Bozkurt, Alper
    SENSORS, 2020, 20 (24) : 1 - 18
  • [7] PHYSIOLOGICAL MONITORING DEVICES
    ALPERT, S
    CRITICAL CARE MEDICINE, 1995, 23 (10) : 1626 - 1627
  • [8] A Wireless Sensor Network for Feedlot Animal Health Monitoring
    Wang, Hai
    Fapojuwo, Abraham O.
    Davies, Robert J.
    IEEE SENSORS JOURNAL, 2016, 16 (16) : 6433 - 6446
  • [9] VitalSticker: A novel multimodal physiological wearable patch device for health monitoring
    Pinto Vieira, Francisco Manuel
    Ferreira, Mafalda Alexandra
    Dias, Duarte
    Silva Cunha, Joao Paulo
    2023 IEEE 7TH PORTUGUESE MEETING ON BIOENGINEERING, ENBENG, 2023, : 100 - 103
  • [10] Monitoring Passive Wireless Devices
    Zohar, Naor
    INTERNATIONAL JOURNAL OF WIRELESS INFORMATION NETWORKS, 2023, 30 (02) : 190 - 197