Accuracy Evaluation of NIM5 Cesium Fountain Clock

被引:0
|
作者
刘年丰
房芳
陈伟亮
林平卫
王平
刘昆
所睿
李天初
机构
[1] NationalInstituteofMetrology
关键词
D O I
暂无
中图分类号
O562 [原子物理学];
学科分类号
摘要
Tie NIM5 fountain clock is the second fountain clock built at NIM(National Institute of Metrology,China),and has been operating stably and sub-continually since 2008.The fountain operates with a simple one-stage optical molasses to collect cold atoms,which reduces the collisional frequency shift dramatically.The fractional frequency uncertainty is estimated to be 2×10-15.The typical frequency instability of 2.5×10-14 is obtained at10 s.Comparisons with other fountain frequency standards worldwide demonstrate agreement within the stated uncertainties.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 50 条
  • [1] Accuracy Evaluation of NIM5 Cesium Fountain Clock
    Liu Nian-Feng
    Fang Fang
    Chen Wei-Liang
    Lin Ping-Wei
    Wang Ping
    Liu Kun
    Suo Rui
    Li Tian-Chu
    CHINESE PHYSICS LETTERS, 2013, 30 (01)
  • [2] The second cesium fountain clock NIM5: Construction and the first evaluation in 2007
    Li Tianchu
    Li Mingshou
    Lin Pingwei
    Wang Ping
    Chen Weiliang
    Liu Nianfeng
    Lin Yige
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM-JOINTLY WITH THE 21ST EUROPEAN FREQUENCY AND TIME FORUM, VOLS 1-4, 2007, : 55 - 57
  • [4] NIM5 Cs fountain clock and its evaluation
    Fang, Fang
    Li, Mingshou
    Lin, Pingwei
    Chen, Weiliang
    Liu, Nianfeng
    Lin, Yige
    Wang, Ping
    Liu, Kun
    Suo, Rui
    Li, Tianchu
    METROLOGIA, 2015, 52 (04) : 454 - 468
  • [5] The transportable cesium fountain clock NIM5: its construction and performance
    Li, Tian-chu
    Lin, Ping-wei
    Li, Ming-shou
    Wang, Ping
    Chen, Wei-liang
    Liu, Nian-feng
    Lin, Yi-ge
    FRONTIERS OF PHYSICS IN CHINA, 2009, 4 (02): : 155 - 159
  • [6] The transportable cesium fountain clock NIM5: its construction and performance
    Tian-chu Li
    Ping-wei Lin
    Ming-shou Li
    Ping Wang
    Wei-liang Chen
    Nian-feng Liu
    Yi-ge Lin
    Frontiers of Physics in China, 2009, 4 : 155 - 159
  • [7] THE TRANSPORTABLE CESIUM FOUNTAIN CLOCK NIM5: ITS CONSTRUCTION AND PERFORMANCE
    Li, Tianchu
    Lin, Pingwei
    Li, Mingshou
    Wang, Ping
    Chen, Weiliang
    Liu, Nianfeng
    Lin, Yige
    PROCEEDINGS OF THE 7TH SYMPOSIUM FREQUENCY STANDARDS AND METROLOGY, 2009, : 314 - 320
  • [8] Accuracy Evaluations of the Cs Fountain Primary Frequency Standard NIM5
    Fang, Fang
    Chen, Weiliang
    Liu, Nianfeng
    Liu, Kun
    Suo, Rui
    Li, Tianchu
    2014 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2014, : 159 - 161
  • [9] Operation of NIM5 fountain with 1.5x10-15 uncertainty and design of new NIM6 in NIM
    Fang, F.
    Liu, N.
    Liu, K.
    Chen, W.
    Suo, R.
    Li, Tianchu
    8TH SYMPOSIUM ON FREQUENCY STANDARDS AND METROLOGY 2015, 2016, 723
  • [10] The progress of the NIM6 fountain clock in NIM
    Fang, Fang
    Chen, Weiliang
    Liu, Kun
    Liu, Nianfeng
    Dai, Shaoyang
    Han, Lei
    Li, Tianchu
    2017 XXXIIND GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE (URSI GASS), 2017,