Determination of radium-226 in ores, nuclear wastes and environmental samples by high-resolution alpha spectrometry

被引:78
|
作者
Sill, C.W. [1 ]
机构
[1] Idaho National Engineering Laboratory, EG&G Idaho, Inc., Idaho Falls, ID 83415, United States
来源
Nuclear and Chemical Waste Management | 1987年 / 7卷 / 3-4期
关键词
BARIUM AND ALLOYS - Applications - ENVIRONMENTAL TESTING - ORE ANALYSIS - Radium Determination - RADIOACTIVE WASTES - Radium Determination - SPECTROMETERS; ALPHA PARTICLE - Applications;
D O I
10.1016/0191-815X(87)90069-6
中图分类号
学科分类号
摘要
The determination of radium-226 by alpha spectrometry has been investigated critically to determine the exact experimental conditions necessary to achieve these objectives. Refractory solids such as soils, ores, and tailing from uranium mills are dissolved completely by fusion with potassium fluoride in the presence of barium-133 tracer. The fluoride cake is then transposed with sulfuric acid to a pyrosulfate fusion with simultaneous volatilization of all silica and fluoride. Radium is precipitated with barium already present in the sample by addition of lead perchlorate to a dilute hydrochloric acid solution of the pyrosulfate cake. The resulting insoluble sulfates are dissolved in an alkaline solution of diethylenetriaminepentaacetic acid, and the radium and barium sulfates are reprecipitated with acetic acid. Some data on radium-226 in wastes and environmental samples and methods for its removal are presented.
引用
收藏
页码:239 / 256
相关论文
共 50 条
  • [1] Determination of radium-226 in environmental and personal monitoring samples
    Lawrie, WC
    Desmond, JA
    Spence, D
    Anderson, S
    Edmondson, C
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 133 - 137
  • [2] Determination of radium-226 in environmental samples by the collector chamber method
    Kumru, Mehmet N.
    Applied Radiation and Isotopes, 1992, 43 (08):
  • [3] Determination of radium-226 in aqueous solutions by α-spectrometry
    Morvan, K
    Andres, Y
    Mokili, B
    Abbe, JC
    ANALYTICAL CHEMISTRY, 2001, 73 (17) : 4218 - 4224
  • [4] Determination of radium-226 in environmental samples by inductively coupled plasma mass spectrometry after sequential selective extraction
    Larivière, D
    Epov, VN
    Evans, RD
    Cornett, RJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (04) : 338 - 343
  • [5] DETERMINATION OF RA-226 BY HIGH-RESOLUTION ALPHA SPECTROMETRY
    SILL, CW
    HEALTH PHYSICS, 1983, 45 (01): : 245 - 246
  • [6] Determination of226Ra in environmental samples using high-resolution inductively coupled plasma mass spectrometry
    Department of Radiation Environmental Assessment, Korea Institute of Nuclear Safety, P.O. Box 114, Yusong, Taejon 305-608, Korea, Republic of
    J. Radioanal. Nucl. Chem., 2 (613-618):
  • [7] Determination of226Ra in environmental samples using high-resolution inductively coupled plasma mass spectrometry
    Yong-Jae Kim
    Chang-Kyu Kim
    Cheol-Su Kim
    Ju-Yong Yun
    Byung-Hwan Rho
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 240 : 613 - 618
  • [8] Determination of 226Ra in environmental samples using high-resolution inductively coupled plasma mass spectrometry
    Kim, YJ
    Kim, CK
    Kim, CS
    Yun, JY
    Rho, BH
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 240 (02) : 613 - 618
  • [9] SEQUENTIAL DETERMINATION OF RADIUM-226, RADIUM-228, ACTINIUM-227, AND THORIUM ISOTOPES IN ENVIRONMENTAL AND PROCESS WASTE SAMPLES
    PERCIVAL, DR
    MARTIN, DB
    ANALYTICAL CHEMISTRY, 1974, 46 (12) : 1742 - 1749
  • [10] Determination of radium-226 in phosphate fertilizers and gypsum by gamma-ray spectrometry
    Godinez, MD