INVESTIGATION OF TEST METHOD OF DC XLPE CABLE.

被引:0
|
作者
Sakamoto, Y.
Fukagawa, H.
Ninomiya, K.
Yamada, Y.
Yoshida, S.
Ando, N.
机构
来源
SAE Preprints | 1981年
关键词
ELECTRIC POWER TRANSMISSION; DC; -; Equipment; POLYETHYLENES; Crosslinking;
D O I
暂无
中图分类号
学科分类号
摘要
There is no standard specification for type test on dc cables except one recommended by CIGRE SC-21 for oil impregnated paper insulated cables up to 600kV. In Japan 250kV class XLPE (Crosslinked Polyethylene) dc cables were manufactured and subjected to a long term test program including the type test mentioned above. As a result it seems that this type test is not suitable for XLPE cables. This paper presents a new consideration in voltage withstand test for XLPE dc cable based on dc insulation characteristics of XLPE.
引用
收藏
相关论文
共 50 条
  • [1] INVESTIGATION ON TEST METHOD OF DC XLPE CABLE
    SAKAMOTO, Y
    FUKAGAWA, H
    NINOMIYA, K
    YAMADA, Y
    YOSHIDA, S
    ANDO, N
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (06): : 1352 - 1362
  • [2] WATERTREE-RESISTANT XLPE CABLE.
    Schusdziarra, W.
    Wiznerowicz, F.
    [J]. Wire, 1985, 35 (03): : 104 - 105
  • [3] Study of 10 kv Joints for XLPE Cable.
    Vlugt, D.N.
    Zandee, P.
    [J]. Elektrotechniek, 1984, 63 (04): : 371 - 373
  • [4] DEVELOPMENT OF A HIGH VOLTAGE DC CABLE.
    LaBozetta, Rocke A.
    [J]. 1978, (606):
  • [5] DEVELOPMENT OF NEW WATER TREE SUPPRESSIVE XLPE CABLE.
    Watanabe, Kiyoshi
    Yagyu, Hideki
    Sekii, Yasuo
    Marumo, Moritada
    [J]. IEEE Transactions on Power Delivery, 1986, PWRD-1 (01) : 27 - 33
  • [6] 275 kV XLPE INSULATED ALUMINUM SHEATHED POWER CABLE.
    Shinoda, Shota
    Marumo, Moritada
    Kobayashi, Masayuki
    [J]. Hitachi Review, 1981, 30 (01): : 41 - 45
  • [7] Service Experience of EDF 20 kV XLPe Insulated Cable.
    Ferran, Jacques
    [J]. RGE, Revue Generale de l'Electricite, 1983, (03): : 139 - 150
  • [8] COMPLETELY DRY CURING AND COOLING PROCESS (FZCV) FOR XLPE CABLE.
    Takaoka, Michio
    Seki, Masaichiro
    Oshima, Hiroto
    Hasegawa, Masakazu
    [J]. Wire journal, 1980, 13 (06): : 64 - 68
  • [9] DEVELOPMENT AND COMMERCIAL USE OF 275 kV XLPE POWER CABLE.
    Kojima, K.
    Fukui, T.
    Yamada, Y.
    Kitai, S.
    Yatsuka, K.
    [J]. Proceedings of the Annual Reliability and Maintainability Symposium, 1980,
  • [10] DEVELOPMENT OF 275 kv INTERNALLY WATER-COOLED XLPE CABLE.
    Kobayashi, T.
    Mori, S.
    Ogino, M.
    Nakagawa, M.
    Kume, I.
    Kojima, H.
    Kawasaki, K.
    Okamoto, T.
    [J]. IEEE transactions on power apparatus and systems, 1985, PAS-104 (04): : 775 - 784