Spectroscopy with CdZnTe γ- and X-ray detectors by modifying the electron trapping to compensate for incomplete charge collection caused by large hole trapping

被引:1
|
作者
Shor, Asher [1 ]
Eisen, Yossi [1 ]
Mardor, Israel [1 ]
机构
[1] Appl. Radiat. Technologies Division, Soreq NRC, Yavne 81800, Israel
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:491 / 496
相关论文
共 50 条
  • [1] Spectroscopy with CdZnTe γ- and X-ray detectors by modifying the electron trapping to compensate for incomplete charge collection caused by large hole trapping
    Shor, A
    Eisen, Y
    Mardor, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (2-3): : 491 - 496
  • [2] Electric field dependence on charge collection of CdZnTe X-ray detectors
    Giakos, G.C.
    Pillai, B.
    Vedantham, S.
    Chowdhuri, S.
    Odogba, J.
    Dasgupta, A.
    Vega-Lozada, V.
    Guntupalli, R.
    Suryanarayanan, S.
    Endorf, R.J.
    Passalaqua, A.
    Kollipara, S.
    Journal of X-Ray Science and Technology, 1997, 7 (02): : 198 - 210
  • [3] Dependence of the DQE of photoconductive X-ray detectors on charge transport and trapping
    Kabir, AZ
    Kasap, SO
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 42 - 52
  • [4] Effects of charge carrier trapping on polycrystalline PbO x-ray imaging detectors
    Kabir, M. Z.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (07)
  • [5] Charge transport and trapping-limited sensitivity and resolution of pixellated x-ray image detectors
    Kabir, MZ
    Kasap, SO
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 26 - 37
  • [6] Impact of charge carrier trapping on amorphous selenium direct conversion avalanche X-ray detectors
    Arnab, Salman M.
    Kabir, M.Z.
    Journal of Applied Physics, 2017, 122 (13):
  • [7] Impact of charge carrier trapping on amorphous selenium direct conversion avalanche X-ray detectors
    Arnab, Salman M.
    Kabir, M. Z.
    JOURNAL OF APPLIED PHYSICS, 2017, 122 (13)
  • [8] A photoelectric study of charge-carrier collection in CdZnTe-based detectors of x-ray and γ radiation
    L. A. Kosyachenko
    E. L. Maslyanchuk
    I. M. Rarenko
    V. M. Sklyarchuk
    Semiconductors, 2004, 38 : 981 - 986
  • [9] A photoelectric study of charge-carrier collection in CdZnTe-based detectors of X-ray and γ radiation
    Kosyachenko, LA
    Maslyanchuk, EL
    Rarenko, IM
    Sklyarchuk, VM
    SEMICONDUCTORS, 2004, 38 (08) : 981 - 986
  • [10] Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trapping
    Kabir, MZ
    Kasap, SO
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (19) : 2352 - 2358