Tritium surface contamination measurements with international credibility

被引:0
|
作者
Whitlock, G.D. [1 ]
机构
[1] Hughes Whitlock Ltd, Malvern, United Kingdom
来源
Fusion Technology | 1992年 / 21卷 / 2 pt 2期
关键词
Nuclear Instrumentation - Calibration - Spectroscopy; Emission;
D O I
10.13182/fst92-a29800
中图分类号
学科分类号
摘要
As world communications improve, a common basis of understanding is essential. It is no longer sufficient to just make measurements, they must be internationally credible. The latest recommendations of ICRP, and the International Standard 'evaluation of surface contamination Part 2 Tritium' are applied in practical terms, to achieve accredited measurements for the evaluation of tritium surface contamination. Three main requirements are explained. 1-A calibration reference source with certified emission rate. 2-A calibratable surface measuring instrument. 3-Reproducible measurements of all forms of surface activity.
引用
收藏
页码:523 / 528
相关论文
共 50 条
  • [1] TRITIUM SURFACE CONTAMINATION MEASUREMENTS WITH INTERNATIONAL CREDIBILITY
    WHITLOCK, GD
    FUSION TECHNOLOGY, 1992, 21 (02): : 523 - 528
  • [2] TRITIUM SURFACE CONTAMINATION
    SIENKIEWICZ, CJ
    FUSION TECHNOLOGY, 1985, 8 (02): : 2444 - 2454
  • [3] TRITIUM SURFACE CONTAMINATION
    SIENKIEWICZ, CJ
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1985, 36 (07): : 594 - 594
  • [4] TRITIUM SURFACE CONTAMINATION - THE SPECIAL PROBLEM
    WHITLOCK, GD
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (08): : 489 - 489
  • [5] Evaluation of unfixed tritium surface contamination
    Postolache, C
    Matei, L
    FUSION SCIENCE AND TECHNOLOGY, 2005, 48 (01) : 413 - 415
  • [6] SURFACE CONTAMINATION FOLLOWING A TRITIUM RELEASE
    JALBERT, RA
    HEALTH PHYSICS, 1986, 50 : S16 - S16
  • [7] A planar-type ionization chamber for tritium surface contamination measurements in fusion facility
    Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang
    Sichuan
    621900, China
    Chen, Zhilin (chenzhilin@caep.cn), 1600, Elsevier Ltd (165):
  • [8] A planar-type ionization chamber for tritium surface contamination measurements in fusion facility
    Chen, Zhilin
    Lai, Caifeng
    Li, Yu
    Cheng, Shenghan
    Yang, Yang
    Peng, Shuming
    FUSION ENGINEERING AND DESIGN, 2021, 165
  • [9] APD imaging probe for tritium surface contamination
    Myers, Richard A.
    Farrell, Richard
    Robertson, Frank
    Dogruel, David
    Willms, R. Scott
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS IX, 2008, 7080
  • [10] Surface contamination of used tritium gas cylinder
    Takeishi, T
    Nishikawa, M
    Katayama, K
    FUSION ENGINEERING AND DESIGN, 2002, 61-62 : 591 - 597