SENSITIVE MEASURING SCHEME IN COLLINEAR FAST-ION-BEAM LASER SPECTROSCOPY: THE OPTICAL PUMPING, STATE-SELECTIVE NEUTRALIZATION AND PARTICLE DETECTION SEQUENCE.

被引:0
|
作者
Silverans, Roger E. [1 ]
Lievens, Peter [1 ]
Vermeeren, Ludo [1 ]
机构
[1] Leuven Univ, Leuven, Belg, Leuven Univ, Leuven, Belg
关键词
ION BEAMS;
D O I
暂无
中图分类号
学科分类号
摘要
A method has been developed to increase the sensitivity of collinear laser spectroscopy on fast alkaline-earth ion beams considerably. The measuring scheme consists of three steps: efficient optical pumping of the ground-state ions to a low-lying metastable state, state-selective neutralization by passage through a vapour charge exchange cell, and separate counting of neutralized and unreacted particles. The state selectivity is due to the dependence of the cross sections on the energy defects involved in the charge exchange reactions. The technique is demonstrated on stable strontium beams, and quantitative results about the sensitivity are derived. Application to very weak beams of isotopes far from stability and further developments are discussed.
引用
收藏
页码:591 / 597
相关论文
共 11 条
  • [1] A SENSITIVE MEASURING SCHEME IN COLLINEAR FAST-ION-BEAM LASER SPECTROSCOPY - THE OPTICAL-PUMPING, STATE-SELECTIVE NEUTRALIZATION AND PARTICLE-DETECTION SEQUENC
    SILVERANS, RE
    LIEVENS, P
    VERMEEREN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 26 (04): : 591 - 597
  • [2] PARTICLE-DETECTION AFTER STATE-SELECTIVE COLLISIONAL IONIZATION IN COLLINEAR FAST BEAM LASER SPECTROSCOPY OF THALLIUM
    SCHUESSLER, HA
    BENCK, EC
    BUCHINGER, F
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (128): : 37 - 40
  • [3] COLLISIONAL IONIZATION AS A SENSITIVE DETECTION SCHEME IN COLLINEAR LASER FAST-BEAM SPECTROSCOPY
    NEUGART, R
    KLEMPT, W
    WENDT, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 17 (04): : 354 - 359
  • [4] Optical isotope shifts on Nd II (26772)11/20 by collinear fast-ion-beam laser spectroscopy
    Fudan Univ, Shanghai, China
    J Phys B At Mol Opt Phys, 15 (3355-3360):
  • [5] Optical isotope shifts of Nd II (26772)(11/2)(o) by collinear fast-ion-beam laser spectroscopy
    Ma, HL
    Shi, W
    Yan, B
    Li, Y
    Fang, DF
    Lu, FQ
    Tang, JY
    Yang, FJ
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1997, 30 (15) : 3355 - 3360
  • [6] COLLISIONAL IONIZATION AS A SENSITIVE DETECTION SCHEME IN COLLINEAR LASER-FAST-BEAM SPECTROSCOPY.
    Neugart, R.
    Klempt, W.
    Wendt, K.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1986, B17 (04) : 354 - 359
  • [7] Optical isotope shifts of Nd II (25524)(11/2)(0) using collinear fast-ion-beam laser spectroscopy
    Ma, HL
    Wei, S
    Bin, Y
    Yong, L
    Fang, DF
    Lu, FQ
    Yang, FJ
    ACTA PHYSICA SINICA-OVERSEAS EDITION, 1997, 6 (09): : 677 - 680
  • [8] Changes in mean square nuclear charge radii of Nd II from optical isotope shifts by collinear fast-ion-beam laser spectroscopy
    Accelerator-Based Atomic and Nuclear Physics Laboratory, Institute of Modern Physics, Fudan University, Shanghai 200433, China
    不详
    Chin. Phys. Lett., 3 (178-179):
  • [9] Changes in mean square nuclear charge radii of Nd II from optical isotope shifts by collinear fast-ion-beam laser spectroscopy
    Ma, HL
    Shi, W
    Yan, B
    Chen, MH
    Chen, ZJ
    Fang, DF
    Lu, FQ
    Tang, JY
    Yang, FJ
    CHINESE PHYSICS LETTERS, 1998, 15 (03): : 178 - 179
  • [10] HIGH-RESOLUTION FIELD IONIZER FOR STATE-SELECTIVE DETECTION OF RYDBERG ATOMS IN FAST-BEAM LASER SPECTROSCOPY
    STRATMANN, K
    HOHMANN, R
    KLUGE, HJ
    KUNZE, S
    LANTZSCH, J
    MONZ, L
    OTTEN, EW
    PASSLER, G
    STENNER, J
    WENDT, K
    ZIMMER, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (06): : 1847 - 1852