Two-dimensional position sensitive microstrip gas chamber for single VUV photons

被引:0
|
作者
Zeitelhack, K. [1 ]
Stolz, A. [1 ]
Bauer, B. [1 ]
Erbe, C. [1 ]
Friese, J. [1 ]
Gernhaeuser, R. [1 ]
Kastenmueller, A. [1 ]
Kienle, P. [1 ]
Koerner, H.-J. [1 ]
Maier-Komor, P. [1 ]
Muench, M. [1 ]
Winkler, S. [1 ]
机构
[1] TU Muenchen, Garching, Germany
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:57 / 60
相关论文
共 50 条
  • [1] A two-dimensional position sensitive microstrip gas chamber for single VUV photons
    Zeitelhack, K
    Stolz, A
    Bauer, B
    Erbe, C
    Friese, J
    Gernhauser, R
    Kastenmuller, A
    Kienle, P
    Korner, HJ
    MaierKomor, P
    Munch, M
    Winkler, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (1-2): : 57 - 60
  • [2] A MICROSTRIP GAS COUNTER FOR SINGLE VUV PHOTONS
    ZEITELHACK, K
    FRIESE, J
    GERNHAUSER, R
    KIENLE, P
    KORNER, HJ
    MAIERKOMOR, P
    WINKLER, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 585 - 587
  • [3] A two-dimensional position sensitive gas chamber with scanned charge transfer readout
    Gómez, F
    Iglesias, A
    Lobato, R
    Mosquera, J
    Pardo, J
    Pena, J
    Pazos, A
    Pombar, M
    Rodríguez, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (03): : 470 - 475
  • [4] Microstrip gas chamber with true two-dimensional and pixel readout
    Angelini, F.
    Bellazzini, R.
    Bosisio, L.
    Brez, A.
    Massai, M.M.
    Perret, A.
    Spandre, G.
    Torquati, M.R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A323 (1-2) : 229 - 235
  • [5] Test of two-dimensional position sensitive detector
    Wang, H.W.
    Xiao, Z.G.
    Liu, Y.Y.
    Wu, H.Y.
    Wei, Z.Y.
    Duan, L.M.
    Li, Z.Y.
    Zhang, B.G.
    Jin, G.M.
    Lu, Z.H.
    Wang, S.F.
    He Jishu/Nuclear Techniques, 2001, 24 (04):
  • [6] Two-dimensional position sensitive neutron detector
    Shaikh, AM
    Desai, SS
    Patra, AK
    PRAMANA-JOURNAL OF PHYSICS, 2004, 63 (02): : 465 - 470
  • [7] Two-dimensional position sensitive neutron detector
    M. Shaikh
    S. S. Desai
    A. K. Patra
    Pramana, 2004, 63 (2) : 465 - 470
  • [8] Microstrip gas chamber as a VUV photosensor for a xenon gas proportional scintillation counter
    Veloso, J.F.C.A.
    Lopes, J.A.M.
    dos Santos, J.M.F.
    Conde, C.A.N.
    IEEE Transactions on Nuclear Science, 1996, 43 (3 pt 2): : 1232 - 1236
  • [9] A microstrip gas chamber as a VUV photosensor for a xenon gas proportional scintillation counter
    Veloso, JFCA
    Lopes, JAM
    dosSantos, JMF
    Conde, CAN
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1232 - 1236
  • [10] Development of an ultra-fast data-acquisition system for a two-dimensional microstrip gas chamber
    Ochi, A
    Tanimori, T
    Nishi, Y
    Aoki, S
    Nishi, Y
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1119 - 1122